Body Size: 60, Type: B (Regulator Type), Pipe Thread: R (Rc), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: R (Rc), Port Size: 06 (3/4), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 50, Backflow: K (w/Backflow Function), Thread: N (NPT), Port Size: 06 (3/4), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Y (Upward), Pressure Units: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric)
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L1 (L-type Plug Connector Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L3 (L-type Plug Connector), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached)], Pump System
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L3 (L-type Plug Connector), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit, (Mounting Screw Attached)], Pump System PE Port
Type), 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and Release Valve: K (N.C.
Round Lock Nut), 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and Release Valve: K (N.C.
Screwdriver Operation Type), 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and Release Valve: K (N.C.