Inch size ARJ310F-N01 5/32" 1/4" 03 07 14-4-11 9 Series ARJ310 Flow Characteristics Inlet pressure: 0.7 MPa ARJ310-01 ARJ310F-01-04 ARJ310F-01-06 0.7 0.7 0.7 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow
(Not including sensor accuracy), Response speed: 150 ms or less Resistance Weight Analog output 0.6% F .S. or less 1.0% F .S. or less 1.5% F .S. or less Accuracy (To display value) (25C) IS Output current: 4 to 20 mA (Within rated pressure range) Current output Note 2) Maximum load impedance: 300 (at 12 VDC), 600 (at 24 VDC), Minimum load impedance: 50 ZSM Linearity: 0.2% F .S.
(Refer to Precautions on page 16-2-24 for details.) 1.5 01: R 1/8 T1: NPT 1/8 Data ZSE40(F)/ISE40-W1 2-M4 x 0.7 thread depth 4 20 30 Rc 1/8 MPa 7 19 20 30 OUT2 OUT1 SET 6.5 R 6.4 18.35 Atmospheric release port Lead wire length 600 (3000) 3.5 12.4 7.8 7 2.5 2.6 30 15.2 42 10.7 4 6 For splash proof use (IP65), insert an air tube into the atmospheric release port.
Table (2) Valve Unit/Valve Plug Connector Assembly Table (3) Vacuum Switch/Plug Connector Assembly How to order If ordering vacuum module with 600 m or the longer lead wire, specify both vacuum module and connector assembly part numbers.
VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.
(Atlanta) 1440 Lakes Parkway, Suite 600 Lawrenceville, GA 30043 Tel: (770) 624-1940 FAX: (770) 624-1943 16850 W. Victor Road New Berlin. Wl 53151 Tel: (414) 827-0080 FAX: (414) 827-OO92 5377 Glen Alden Drive Richmond, VA 23231 Tel: (804) 222-2762 FAX: (80a) 222-5221 SMC Pneumatics Inc.
Max. 120"F (50'C) 20ms or less (7OPS|) 600 cpm Nonlocking push type, (std-) Slotted locking type, Knob type (opt.)
(Including insulating material) 2.35 mm 2.35 mm Rated current 10 A 8 A Rated voltage 600 V 600 V Contact resistance 5 mW or less Insulation resistance 100 MW or more Withstand voltage 1.4 kV Rating/Performance Ambient temperature Connector 25 to 80C Cable 30 to +105C 10 to +105C Min. bending radius (Fixed) 94 mm 110 mm Protection class IP67 (Only with screw tightened) Allowable repeated insertion
Also when exceeding a 600 mm stroke, specify -XB11 at the end of the part number. (Except 10) Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.
10% Power consumption 0.45 W Surge voltage suppressor Varistor Indicator LED Manufacturer OMRON Rockwell Automation Electrical wiring G1/2, M12 connector M12 connector Contact resistance 25 m or less 50 m or less Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance) Max. voltage 24 VDC Max. load current 50 mA Max. load inductance 0.5 H Insulation voltage 300 V 600
Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.
VBA2A: Qb = 600 [L/min (ANR)] VBA4A: Qb = 1050 [L/min (ANR)] Refer to Flow Rate Characteristics on pages 1012 and 1013. Avoid pulsation. (Max. 0.05 MPa) NO: Need no tank The VBA4A can supply necessary pressure. NO Judgement of flow rate YES YES The VBA2A cannot obtain necessary pressure. Select the tank from table below.
Bore size (mm) Standard stroke (mm) Bore size (mm) Rod diameter (mm2) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 32 675 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 1082 40 40 1651 50 2804 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 50 Theoretical force (N) = Pressure (MPa) X Piston area (mm2) 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 Intermediate
VBA2lA: Qb = 600 [L/min (ANR)] VBA4lA: Qb = 1050 [L/min (ANR)] Refer to Flow-rate Characteristics on pages 3 and 4. Avoid pulsation. (Max. 0.05 MPa) NO: Need no tank The VBA4lA can supply necessary pressure. NO Judgement of flow rate YES YES The VBA2lA cannot obtain necessary pressure. Select the tank from table below.
, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.
1000 Manufacturable stroke range [mm] 11-LEFS16 V V V V V V V V V V 50 to 500 11-LEFS25 V V V V V V V V V V V V 50 to 600 11-LEFS32 V V V V V V V V V V V V V V V V 50 to 800 11-LEFS40 V V V V V V V V V V V V V V V V V V 150 to 1000 *Please consult with SMC for non-standard strokes as they are produced as special orders.
Applicable Stroke Table : Standard Model Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Manufacturable stroke range [mm] LEFS16 50 to 500 LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * Please consult with SMC for non-standard strokes as they are produced as special orders. The actuator and controller/driver are sold as a package.
W Note 2) 230 W Note 1) Cooling capacity 900 W Note 2) 600 W Note 1) Heating capacity Temperature stability Note 3) 0.018 to 0.054F (0.01 to 0.03C) Pump capacity Refer to performance chart.
bearing) 40 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer