Series: Standard, Mounting: MS2, Side Lug, Bore Size: 8" - Large Bore, Stroke: 20", Air Cushion / Rod Boot: -, Thread: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Series: Standard, Mounting: MS4, Side Tapped, Bore Size: 6" - Large Bore, Stroke: 20", Air Cushion / Rod Boot: -, Thread: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Series: Standard, Mounting: MS4, Side Tapped, Bore Size: 5" - Large Bore, Stroke: 20", Air Cushion / Rod Boot: -, Thread: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.
Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.
Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, POWERLINK, PNP, SERIAL TRANSMISSION SYSTEM, 645, 200 lb
/4000/5000, SV1000/2000/3000, SY3000/5000/7000, S0700 Solenoid valve Max. number of solenoid valves 32 solenoid coils Output type of solenoid PNP (Negative common) Connected load Solenoid valve with surge voltage suppressor 24 VDC, 1.0 W or less (SMC) Short circuit protection YES Protocol Ethernet POWERLINK Media 100 BASE-TX Fieldbus Communication speed 100 Mbps Communication type Half duplex
L/min PFMC7501(500 L/min) PFMC7102(1000 L/min) kPa kPa 200KPa 200KPa 400KPa 400KPa L/Min L/Min PFMC7202(2000 L/min) kPa L/Min -69No.PF-OMS0001CN-A IN 3F.S.8cm IN OUT [%F.S.]
A 1 1000 Metric 6 7 2 2000 Inch 1/4" 10 3 3000 Elbow (mm) Applicable tube O.D.
2000 25 32 40 25 32 40 1500 1500 1000 1000 500 500 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T and MT are selected.
2000 1000 1000 0 0 0 10 20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz *The cooling capacity will be reduced by 300W when option: T and MT are selected.
[oC] correction coefficient Less than 1000m 45 1.00 1000m or more Less than 1500m 42 0.85 1500m or more Less than 2000m 38 0.80 2000m or more Less than 2500m 35 0.75 2500m or more Less than 3000m 32 0.70 Installation/Operation in accordance with the UL standard The product cannot be used in the environment shown below: Environment at an altitude of 2000 meters or more Environment at a
Installation/Operation in accordance with the UL standard (for the optional UL compliant model) For operation of the UL compliant model (available as an option, HRSH***-*20-*S*) in UL compliant conditions, the product cannot be used in the environment shown below: Environment at an altitude of 2000 meters or more Environment at a pollution degree of 3 or more Location where the ambient
[oC] correction coefficient Less than 1000m 45 1.00 1000 m or more Less than 1500 m 42 0.85 1500m or more Less than 2000m 38 0.80 2000m or more Less than 2500m 35 0.75 2500m or more Less than 3000m 32 0.70 Installation/Operation in accordance with the UL standard The product cannot be used in the environment shown below: Environment at an altitude of 2000 meters or more Environment at
Recirculating fluid flowrate L/min Fig. 6-3 Pump capacity ofHEC006 4) Pressure loss of radiating water 0.025 0.020 Pressure loss MPa 0.015 0.010 0.005 0.000 0 2 4 6 8 10 12 Radiating water flwrate L/min Fig. 6-4 Pressure loss of HEC006 6-4 Specifications 6.2.2 Performance of HEC012 1) Cooling capacity Radiating Water Temp.20 oC Radiating Water flowrate10L/min 3000 2500 Cooling capacity W 2000
If it has a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Operating characteristics
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.)