Size: 70D [7 m³/min (ANR)], Thread: Rc, Port Size: 10 (1), Option: Auto Drain, 1.0 MPa, Bracket: B (Bracket)
Size: 70D [7 m³/min (ANR)], Thread: Rc, Port Size: 10 (1), Option: H (Medium Pressure with Auto Drain, 1.6 MPa)
Size: 22, Type: Q (Rapid Supply and Exhaust Function), Thread: Rc, Port Size: 02 (1/4), Tubing O.D: ø10
Size: 22, Type: R (Pressure Reduction Function), Thread: Rc, Port Size: 02 (1/4), Tubing O.D: ø10
Size: 32, Type: Q (Rapid Supply and Exhaust Function), Thread: Rc, Port Size: 03 (3/8), Tubing O.D: ø10
Size: 32, Type: R (Pressure Reduction Function), Thread: Rc, Port Size: 03 (3/8), Tubing O.D: ø10
Size: 32, Type: Q (Rapid Supply and Exhaust Function), Thread: Rc, Port Size: 02 (1/4), Tubing O.D: ø10
Size: 42, Type: Q (Rapid Supply and Exhaust Function), Thread: Rc, Port Size: 03 (3/8), Tubing O.D: ø10
Size: 42, Type: Q (Rapid Supply and Exhaust Function), Thread: Rc, Port Size: 04 (1/2), Tubing O.D: ø10
Size: 22, Type: R (Pressure Reduction Function), Thread: Rc, Port Size: 01 (1/8), Tubing O.D: ø10
Size: 42, Type: R (Pressure Reduction Function), Thread: Rc, Port Size: 04 (1/2), Tubing O.D: ø10
Size: 32, Type: R (Pressure Reduction Function), Thread: Rc, Port Size: 02 (1/4), Tubing O.D: ø10
Size: 42, Type: R (Pressure Reduction Function), Thread: Rc, Port Size: 03 (3/8), Tubing O.D: ø10
Function: 1 (2 Position Single), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 1 (2 Position Single), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 2 (2 Position Double), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)