Magnet: D (Built-in), Mounting: B (Through-hole), Bore Size: 300 (3"), Stroke: 300 (3")
Magnet: None, Mounting: B (Through-hole), Bore Size: 300 (3"), Stroke: 300 (3"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC4 (Scraper)
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 300 (3"), Stroke: 300 (3"), Body Option: C (Rubber Bumper)
PRESSURE SENSOR FOR GEN FLUIDS, INSTRUMENTATION, PSE200/300/530-560, DA, PSE200/300/530-560 1/4" PT, 0.40124 lb
Please contact us for the latest version.sales@ocaire.com, PRESSURE SENSOR FOR GEN FLUIDS, INSTRUMENTATION, PSE200/300/530-560, DA, PSE200/300/530-560 1/4" PT, 0.40124 lb
PRESSURE SENSOR FOR GEN FLUIDS, INSTRUMENTATION, PSE200/300/530-560, DA, PSE200/300/530-560 1/4" PT, 0.40124 lb
Set the total current capacity to 300 mA. 300 mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. 11.
Item Setting value, setting Default AXIS AXIS AXIS AXIS range value 1 2 3 4 0:mm 3 0 150 300 450 1:inch 2:degree 3:PLS Pr.1 Unit setting Movement Pr.2 Pulse number amount per 1 to 20 (Note 1) 20 2 3 152 153 302 303 452 453 pulse per rotation(AP) (Unit: PLS) Pr.3 Moving amount The setting value range differs according to the "Pr.1 Unit setting". 20 4 5 154 155 304 305 454 455 per rotation
When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used. 27 - When the external Regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
When set to the factory setting (Pn600 = 0), the DRIVERs built-in option has been used. 26 - When the external Regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
Assy 2V Assy Assy 18 - No.ZB-OM00301 O Assy V Assy Assy V Assy Assy 19 - No.ZB-OM00301 1TK1-123 2 3 1VKJ 2 3 1 0.1 2 0.1 3 0.15 -0.2 2 20 - No.ZB-OM00301 () ( ) ONOFF () 0.1Nm 1 ON 0 ) () () 1 (PA) 0 (AR) () 21 - No.ZB-OM00301 AXT661-12 0.2~0.33mm 2 (1.7mm) ) DXT170-71-1 3.2~3.7mm (DXT170-75-1) 2 0.2~0.33mm (1.7mm) (ACB (1mm) 22 - No.ZB-OM00301 N.C. 300
80 230 32 15 31 42 283 355 270 485 568 IDF Series 6-3 Dimentions 6 3 IDX-OM-W010 Air Dryer 6 References IDF15E1 603 54 41 300 Ventilation air outlet 16 1 C R Compressed inlet R 1 C Compressed air outlet Switch with lamp Evaporation thermometer 87 Drain separator Ventilation direction Ventilation 578 direction Terminal block [200VAC specification] 396 Drain tube (O.D.10, length approx.0.8m
IDF11E Rc3/4 IDF Series 6-3 6 3 IDX-OM-W011 6 IDF15E1 mm 603 41 54 300 16 C R 1 C R 1 87 578 [AC200V] [AC200V] 396 0.8m (10, (:10, :0.8m) 43 15 270 13 4x 380 101 258 314 [AC100V] (:1.9m [AC100V] [AC200V] [AC200V] ( 17) (17) 1.9m 6-4 IDF1E3E ILS 3 PTC (50/60Hz) AC100/100,110V 2 1 (BK) (WH) 1 SYMBOL DESCRIPTION M 2 1 S 5 CM 2 (GR) CM COMPRESSOR MOTOR PC OLR C (SY) (50/60Hz)
Documents 7.1 Specifications Models Specification IDFA60-23 IDFA70-23 IDFA80-23 IDFA90-23 Fluid Compressed air Operati Inlet air temperature oC 5 to 65 ng range Inlet air pressure MPa 0.15 to 1.0 (Note 3) (Note 1) Ambient temperature (Humidity) oC 2 to 45 (Relative humidity 85 % or less) Outlet air 3 oC 204 312 552 810 pressure dew Standard condition (ANR) (Note 2) point Outlet air 7 oC 300
Series 6 1 IDX-OM-W017 6 6-2 GWP (GWP) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) IDFA Series 6-2 GWP 6 2 IDX-OM-W017 6 6-3 mm IDFA4E15E1 A B C D E F G H J K L M N P Q IDFA3E Rc3/8 226 410 473 67 125 304 33 73 31 36 154 21 330 231 15 IDFA4E Rc1/2 453 13 498 283 275 IDFA6E 455 275 Rc3/4 15 485 568 355 300
L M N P Q IDFB3E 3/8 8.9 16.1 18.6 2.6 4.9 12.0 1.3 2.9 1.2 1.4 6.1 0.8 13.0 9.1 0.6 [226] [410] [473] [67] [125] [304] [33] [73] [31] [36] [154] [21] [330] [231] [15] 17.8 0.5 IDFB4E 1/2 [453] 17.8 [13] 1 1.1 10.8 [453] 1.2 [283] 3.1 [275] 10.8 17.9 10.6 1.7 9.1 1.3 0.6 9.4 3.1 IDFB6E [455] 0.6 [270] [31] [42] [80] [230] [32] [15] [240] [80] [275] 3/4 [15] IDFB8E 19.1 22.4 14.0 1 1.8 [300
] IDFB11E [485] [568] [355] IDFB15E 1 11.8 23.7 22.8 1.6 2.1 16.6 3.4 10.2 1.7 0.6 10.6 4.0 15 12.4 0.6 [300] [603] [578] [41] [54] [396] [87] [258] [43] [15] [270] [101] [380] [314] [16] 6-3 6 4 IDFB Series IDX-OM-W020 6 6-4 IDFB3E 1 2 CM P FM1,2 1 2 PE OLR TB PTC PTC PE 1 2 ILS PRS S TB P CM FM P IDFB4E / 6E / 8E S R GFCI CM FM1,2 OLR V PTC PTC ILS PRS TB
Socket with check valve 300 KKA4: Plug and socket with check valve on both sides Insertion force [N] 200 100 KKA3: Plug without check valve.
(P2) () 3) 4) 5) 23 5 No.VEX-OMY0001 VEX3 3 / DC () 5 20N 1) 2) 1 ()ISO VG32 2 ISO VG32 ,(SDS) 6 No.VEX-OMY0001 VEX3 3 / () 30 ( ) , 1 VG32 2 ()ISO VG32 7 No.VEX-OMY0001 VEX3 VEX3 12,22,32,42 ,300mm DXT170-80-A1) 2) Lmm 2 300 6 600 1 (2 ) AC100V 10 1000 2 (2 ) AC200V 15 1500 3 (2 ) AC 20 2000 DC L 4 :+ :DC 25 2500 DXT170-71-1 30 3000 0.20.33mm ( 1.7mm) DC : M 3.23.7mm
In Administrator mode, a timeout occurs after 300 seconds of inactivity and the application returns to Monitor mode. A timeout countdown is displayed to the right of the "Administrator mode" label. The NFC communication is not accessed all the time. Therefore, always update the content displayed on the screen by clicking the "Refresh" button when reading the parameters.