Do not apply rotational torque to the cylinder rod. In order to prevent rotational torque from acting upon the cylinder rod, mount it so that the contacting surfaces of the pallet and cylinder are parallel to one another. 4. Do not use oil, etc. on the sliding parts of the piston rod. This can cause trouble with retraction or other malfunctions.

Do not exceed the screw-in torque of 3.5 Nm when installing piping. Exceeding this value may cause malfunctioning of the sensor. 4. Do not use pressure sensors with corrosive and/or inflammable gases or liquids. 5. Connecting the sensor cable (Option) Hold the female connector of the sensor cable with your fingers and carefully insert it into the connector.

Do not apply strong impacts or excessive moment to the slide table (slider). Do not apply strong impacts or excessive moment, etc., when mounting workpieces. 2. Do not mount cylinders as they are twisted. When mounting, be sure for a cylinder tube not to be twisted.

Do not operate in locations in an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat resources, block off radiant heat. Maintenance Mounting Caution Caution 1.

Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. Caution 3. In locations near heat sources, block off radiant heat. 1. Check the model number, size, etc. before installing. The TLM and TILM series do not have the model number displayed on the product due to the resin material used.

Do not use at temperatures (fluid or ambient temperatures) higher than the prescribed operating conditions.

Do not use at temperatures (fluid or ambient temperatures) higher than the prescribed operating conditions.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 4.

Regulator and filter regulator 1) Be sure to unlock the handle before adjusting the pressure and to lock it after the pressure is set. 2) During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 3) Do not install it iin an area that is exposed to high temperature or humidity, because doing so will lead to improper operation

Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 2: These alarms do not occur on the product of the power specification '-20'. 3: These alarms do not occur on the product of the cooling method -A. 4.10 Register Map HRSH Series 4-20 HRX-OM-Q033 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid

Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 2: These alarms do not occur on the product of the cooling method -A. 3: These alarms do not occur on HRS200 series. 4.10 Register Map HRS100/150 Series 4-20 HRX-OM-S010 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid set temperature can be

Note) The dedicated software (LEC-BCW) is required. * When controller equipped type is selected when ordering the LE series, you do not need to order this driver. * When pulse signals are open collector, order the current limiting resistor (LEC-PA-R-m) separately. The driver is sold as single unit after the compatible actuator is set.

Do not operate exceeding the operating pressure range. 2. Do not operate exceeding the operating temperature range. 3. Fluid Do not operate with gases. 4.

Do not mount this kit on other products. Carefully read the procedure manual included with this kit before performing the installation.

Do not expose the product to direct sunlight for an extended period of time. 1/4 12 to 14 3/8 22 to 24 3. Do not use in a place subject to heavy vibration and/or shock. 1/2 28 to 30 4. Do not mount the product in locations where it is exposed to radiant heat. 2.

Do not apply torque at other points as the product may be damaged. Rotate body A manually for positioning after installation. 12. Do not use body A and/or elbow body for applications involving continuous rotation. Mounting Body A and the fitting section may be damaged. Warning 1.

Do not apply torque at other points as the product may be damaged. Rotate body A manually for positioning after installation. 12. Do not use body A and/or elbow body for applications involving continuous rotation. Mounting Body A and the fitting section may be damaged. Warning 1.

Do not apply torque at other points as the product may be damaged. Rotate body A manually for positioning after installation. 12. Do not use body A and/or elbow body for applications involving continuous rotation. Mounting Body A and the fitting section may be damaged. Warning 1.

Do not disassemble the product or make any modifications, including additional machining. 6. Do not use tools such as pliers to rotate the knob. AS-T It can cause idle rotation of the knob or damage. It may cause human injury and/or an accident. ASP 7. Verify the air flow direction. 4. The flow rate characteristics for each product are representative values.

Do not use tools, such as pliers, to rotate the knob. This can cause the idle rotation of the knob or damage. 3. Do not overtighten the lock nut. It is possible to tighten the lock nut (hexagon) manually. When tightening further with tools, tighten by approximately 15 to 30. Overtightening may cause breakage.