Specifications Fluid Air Operating pressure range PSI (MPa) Internal pilot 22~100 (0.15 to 0.7) Body ported type Ambient and fluid temperature F Max. 122 Response time ms 25 or less Max. operating frequency Hz 5 Manual override Non-locking push type, Push-locking slotted type Pilot exhaust Individual pilot exhaust type.

Adjusting screw width across flats Lock nut A tightening torque Model 12-REA25 12-REA32 12-REA40 12-REA50 12-REA63 Width across flats (mm) 5 5 6 8 8 Model 12-REA25 12-REA32 12-REA40 12-REA50 12-REA63 Tightening torque (Nm) 1.2 1.2 2.1 3.4 3.4 5. Do not scratch or gouge the external surface of the cylinder.

(XC85,X446)P19 c) 4. 17 - 3-2. 3-2-1. 1 2 3 3-2-2. 1 2 3 4 5 6 7) 8 1) 2) 33. 331. 4. 20 25 32 40 CM20Z-PS CM25Z-PS CM32Z-PS CM40Z-PS 1 3-3-2. 1 2 3 4 18 - 4. (XC85,X446) 4-1. -XC85 GR-H-010(10g) <> <> 4-2. PTFE X446 GR-F-005(5g) 1) 19 - 2) () 5. 5. 20 - 6. 1.

(Refer to the figure below.) 4) Remove the cable gland (5) and plain washer (6) and rubber seal (7) . 2. Wiring 1) Pass them through the cable (8) in the order of cable ground (5), washer (6), rubber seal (7), and then insert into the housing (4). 2) Dimensions of the cable (8) are the figure as below.

This is recommended because it can absorb off-centering, compared with direct mounting type. 6.1 16 M 5 Part name Part number P368010-24 Fork lever assembly M N P368010-25 Fork lever assembly S Resin connector (Non-explosion proof specification) L2=31 (M type: 55) 39 (M type: 63) Optional cable connectors are available for different cable sizes.

Recommended tightening torque:20 to 25 Nm The product may break, if it is held by hand. Piping to the Vacuum Port Adapter Vacuum port adapter When mounting or removing the fitting, etc. to or from the vacuum port adapter, hold the vacuum port adapter with a wrench (across the flats 19). Recommended tightening torque:3 to 5 Nm The product may break, if it is held by hand.

6 1 2 3 4 5 6 Air blow circuit 1 2 Available LMD1 LMD2 Not available Dimensions LMD1 n: Stations L 58 94 130 166 202 238 L1 44 80 116 152 188 224 Model LMD1-1 LMD1-2 LMD1-3 LMD1-4 LMD1-5 LMD1-6 n 3 6 9 12 15 18 L1 4 x 5.5 3 x Rc1/8 n = Rc 1/8 LMD2 n: Stations L1 25.5 44.5 63.5 82.5 101.5 120.5 L 38 57 76 95 114 133 Model LMD2-1 LMD2-2 LMD2-3 LMD2-4 LMD2-5 LMD2-6 n 2 4 6 8 10 12 2 x 6.5 n

ALARM 24 Alarm output NO. 3 13 NO. 4 4 COM 12, 25 Common The output terminal common.

For example, when the output voltage is 1 to 5[V], the F.S. will be 5-1 = 4[V]. (Reference: 1%F.S. = 4 0.01 = 0.04[V]) F.S. (full span/full scale) O The resistance value of a component between the voltage outputting element and the output line at the output of the analogue voltage output.

Note 3) 5 to 50C for the products with the digital pressure switch Note 4) Without accessories Accessories (Option)/Part No.

Integrated display 7 Rated flow range (Flow rate range) Option 2 (Refer to page 907.) 0.2 to 10 (5) l/min 0.5 to 25 (12.5) l/min 1 to 50 (25) l/min 2 to 100 (50) l/min 10 25 50 11 Option 1 (Refer to page 907.) ( ): Fluid: CO2 Calibration certificate Flow adjustment valve None With calibration certificate Nil A Nil S None Yes The certificate is written in English and Japanese.

Variations LVQ20 Model LVQ30 LVQ40 LVQ50 LVQ60 Orifice diameter Tubing outside dia. 4 8 10 16 22 Fitting type Millimeter Symbol V S Fittings LQ1 LQ2 Body class 2, 3, 4, 5, 6 2, 3, 4, 5 6 10 12 19 25 Valve type Inch Type Symbol 1/4 3/8 1/2 3/4 1 Basic type N.C. N.C. PB PA PA Applicable tubing size Body class Connecting tubing O.D. N.O. PB B A B A B A Symbol 2 3 4 6 5 N.C. N.O.

Nil With R3 3 RB 15 N Without (Roller specification) R5 5 RC 20 Applicable Stroke Table Stroke Size 50 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 25 32 40 Controller Nil Without controller CH With controller C 5 H 7 T (Communication protocal Interface Communication plug connector I/O cable*2 /Input/Output) Symbol Type Applicable interface 5 Parallel inputNPN) Nil Without

Lock unit model Bolt Hexagon wrench size Tightening torque (Nm) MWB32 MWB40 MB-32-48-C1247 4 5.1 MWB50 MWB63 MB-32-48-C1249 5 11 Foot MB-80-48AC1251 MWB*80 6 25 MWB*100 Other MB-80-48BC1251 There is a vent hole on the element. If the ventilation is not adequate, there will be locking/ unlocking delay or operation failure. Install the cylinder so that the element is not covered.

Floating joint Body Fig. 3-5 [Ex.-5] (-XC57) 7 The misalignment can be checked by the following procedure.

1.0 MPa Output for PF2A3 Analogue voltage output (non-linear), Output impedance: 1 k Voltage output 1 to 5 V Output impedance 1 k Analogue output Current output 4 to 20 mA Load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Accuracy 1 5%F.S. max.

MH*-OMM0057 MHL2-10D* MHL2-16D* MHL2-20D* MHL2-25D* MHL2-32D* MHL2-40D* 1. 23 2. 4 3. 3-1 5 3-2 5 3-3 5 3-4 67 3-5 8 3-6 9 3-7 1012 3-8 13 4. 4-1 13 4-2 14 4-3 15 4-4 16 1 - *1) (ISO/IEC) (JIS) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment

Noise countermeasures 12 5. Structure and Measuring Principle 5-1. Structure 13 5-2. Measuring Principle 14 5-3. Relationship Between Pulse and Count 14 6. Troubleshooting 6-1. Troubleshooting for Measuring Function 1516 6-2.

10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2.