) () () Dimensions A Stroke Model B C D Note) LG1H202100-F LG1H202200-F LG1H202300-F LG1H202400-F LG1H202500-F LG1H202600-F LG1H202700-F LG1H202800-F LG1H202900-F LG1H202-1000-F LG1H202-1200-F 100 200 300 400 500 600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100 1200 1300 1500 50 150 250 350 450 550 650 750 850
Middle stroke 120 Long stroke 60 Lubrication Not required Action Double acting Note 2) Gripping force Effective gripping force per finger (N) 19 48 90 141 Short stroke 8 12 16 20 Opening/closing stroke (Both sides) (mm) Middle stroke 16 24 32 40 Long stroke 32 48 64 80 Short stroke 65 155 350 645 Note 3) Weight (g) Middle stroke 85 190 445 850 Long stroke 120 275 650 1,225 Note1) This is
NIL S Nominal size 10 15 Connecting port E: Axial side R: Body side Port Port Applicable Auto Switches/Refer to pages 797 to 850 for further information on auto switches.
Size 10 20 30 50 MSQ Auto switch MSZ MSZ Nil Without auto switch (Built-in magnet) CRQ2X MSQX A With adjustment bolt MRQ Applicable Auto Switches/Refer to pages 797 to 850 for detailed auto switch specification.
Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740 35 1200 1650 Air flow capacity l/mim(ANR) 614 (640) 996 (850
Pilot valve symbol 1 2 3 4 5 6 100 AC 200 AC 110 AC 220 AC 24 DC 12 DC Nil Y Nil Y Nil Nil Nil Nil K1 K1 J1 J1 Q1 Q2 N1 N2 q w e r t y u i Combinations (1) to (8) in the above table are the only possible options. 850 Compact Vacuum Ejector Series ZA How to Order 08 ZZA1 3 P Manifold Right common air pressure supply (P) port (viewed from the vacuum (V) port side) ZA Number of stations 01
10 to 300 451 to 500 10 to 600 5 to 300 20 to 1100 12 to 750 6 to 400 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 501 to 600 20 to 900 12 to 540 6 to 270 24 to 1200 16 to 800 8 to 400 30 to 1200 20 to 850 10 to 300 601 to 700 20 to 630 12 to 420 6 to 230 24 to 930 16 to 620 8 to 310 30 to 1200 20 to 850 10 to 300 In-line Stroke range 701 to 800 20 to 550 12 to 330
One power supply system for temperature control of 2 channels Less work-hour for wiring Height [mm] Height Width Depth HRL100 1538 954 715 HRL200 Power cable entry HRL300 1839 1079 850 Width Depth Energy saving Compressor Inverter control The inverter respectively controls the number of motor rotations of the compressor, fan and pump depending on the load from the users equipment.
Power supply output VI: 1.0 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 1.0 [kVA] x 0.85 = 0.85 [kW] = 850 [W] Cooling capacity = Considering a safety factor of 20%, 850 [W] x 1.2 = 1020 [W] HRZ W Efficiency Q = P = HRZD In this example, using an efficiency of 0.7: HRW 800 0.7 = = 1143 [W] HECR Cooling capacity = Considering a safety factor of 20%,
closing stroke (Both sides) mm Note 2) Weight g Effective gripping force per finger N Action Model MHT Finger open side Finger close side MHY MHF2-8D MHF2-8D1 MHF2-8D2 MHF2-12D MHF2-12D1 MHF2-12D2 MHF2-16D MHF2-16D1 MHF2-16D2 MHF2-20D MHF2-20D1 MHF2-20D2 0.6 1.0 1.9 1.6 3.0 5.8 4.1 7.4 14.0 7.3 13.7 26.6 0.7 1.1 2.0 1.9 3.3 6.1 4.9 8.2 14.9 8.7 15.1 28.0 65 85 120 155 190 275 350 445 650 645 850
Refer to pages starting with 181 for mounting. 3-8H10 depth 10 30 A B Stroke Model LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 350 450 550 650 750 850 370 470 570 670 770 870 500 600 700 800 900 1000 B 95 100 95 8-6.2 110 95 20 95 A Positioning Time Guide Positioning time Positioning time (sec.)
/ 1070 810 / 940 850 / 1070 1450 / 1890 2000 / 2500 Circuit Breaker(Note 3) A 10 15 Condenser Air cooling Refrigerant R407C (HFC) Refrigerant Charge g 42010 47010 73010 83010 55010 72010 Air IN/OUT Connection R1 R11/2 R2 Drain Connection mm 10 Coating Color Panel: Urbanwhite 1 Base: Urbangray 2 Weight kg 54 62 100 116 Applicable Compressor(Standard) kW 22 37 55 75 Note1: The data for m3/
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
128 138 32 122 135 149 162 176 189 203 216 230 243 32 94 108 121 135 148 162 175 189 202 215 40 184 201 217 233 250 266 282 299 315 331 40 145 161 177 194 210 226 243 259 275 292 50 332 357 383 408 433 458 483 508 533 50 284 309 334 359 384 410 435 460 485 63 513 544 575 606 637 667 698 729 760 63 452 483 514 545 576 606 637 668 699 80 961 1010 1059 1109 1158 1207 1256 1305 1354 80 850
rear clevis 1.8-28 ISO/VDMA Air Cylinders Series CP95 Maximum stroke determination Allowable theoretical strokes (mm) Mounting type Accessories Pressure Bore (mm) [MPa] 32 40 50 63 80 100 L F (front) G (rear) L 0.2 0.3 F (front) 0.4 0.5 0.6 0.7 0.8 0.9 1 *) *) *) *) *) *) 0.2 G (rear) 0.3 1160 1360 0.4 940 1160 1350 0.5 1080 830 1020 1190 0.6 770 980 750 920 1080 0.7 700 900 680 850
closing stroke (Both sides) mm Note 2) Weight g Effective gripping force per finger N Action Model MHT Finger open side Finger close side MHY MHF2-8D MHF2-8D1 MHF2-8D2 MHF2-12D MHF2-12D1 MHF2-12D2 MHF2-16D MHF2-16D1 MHF2-16D2 MHF2-20D MHF2-20D1 MHF2-20D2 0.6 1.0 1.9 1.6 3.0 5.8 4.1 7.4 14.0 7.3 13.7 26.6 0.7 1.1 2.0 1.9 3.3 6.1 4.9 8.2 14.9 8.7 15.1 28.0 65 85 120 155 190 275 350 445 650 645 850
Applicable strokes: 150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1H1011SC-150-F2-X2 Allowable Moment (Nm) Allowable dynamic moment Allowable static moment LJ1H10 Model Mounting orientation Load movement direction Pitching Rolling Yawing 10.2 12.8 10.2 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep 2000 a = 1000 L1 (mm) Pitching m : Transfer load (kg) a : Work piece
T dimension) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) Note) N.C. and N.O. common 30 10 (1 1/4B) 12 (1 1/2B) 16 (2B) 45 Note) The symbol Z indicates lengths other than the standard T length and adjustment range. Specify the T length in this case.
GB 4.1 TECHNICAL FEATURES OF DRYERS SERIES PDE 3 20 -S MODEL PDE3-S PDE5-S PDE8-S PDE10-S PDE15-S PDE20-S Flow rate at 35C 7 bar [l/min] 350 550 850 1100 1800 2300 [m/h] 21 33 51 66 108 138 [Scfm] 12 19 30 39 64 81 Dew point* +37.8F (+3C) equal to 0.73 gr/Nm di H2O Ambient temperature nom (max) [F/C] +100 (+115) / +37.8 (+45) Min. ambient temperature [F/C] +34 / +1 Nom (max) inlet air temperature