SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-T-P-N02-WY"

S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .

TC Applicable bore size (mm) TD TH TK TN TT TU TV TW TX TY CJ-010B CJ-016B 6, 10 4.5 3.3 29 18 3.1 2 9 40 22 32 12 16 5.5 5 35 20 6.4 2.3 14 48 28 38 16 Clevis pin L l t t m m D d9 d Material: Stainless steel Part no. d Applicable bore size (mm) D l L m t CD-J010 CD-Z015 CDP-1 3 6, 10 3.3 12.2 15.2 1.2 0.3 4.8 16 5 18.3 22.7 1.5 0.7 8.6 20, 25 9 19.2 25 1.75 1.15 10-5-24

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 120 lb

Cable color T erminal no. Brown 2 A B-1 Red 1 A A-1 Cable length (L) Orenge 6 B B-2 Yellow 5 B A-2 1 1.5m Green 3 COM-A / COM B-3 Blue 4 3 3m COM-B / A-3 Shield 5 5m Cable color T erminal no.

RH PH P A FW WE PL HR 20.5 F A' 8.5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L LA PL HA Z + Stroke HA U B D Width across flats MB (lock plate fixing bolt) WD MA (Stroke adjuster) QW WR W H Section AA' TH (Head height of mounting bolt) +0.03 0 RL T TB +0.03

T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL

-2-2P (Rc 1/2) VPA344 VP300-17-1 VP300-24-4 M4 x 0.7 x 41 VPA544 VP500-17-1 Series Thread type VP500-24-3 M5 x 0.8 x 50 3 5 7 P F N T VPA344 VPA544 VPA744 Rc G NPT NPTF VPA744 VP700-17-1 VP700-24-1 Caution Port size Mounting screw tightening torques VPA344 1/8 1/4 VPA544 1/4 3/8 VPA744 3/8 1/2 Symbol 1 2 M3: 0.6 Nm M4: 1.4 Nm M5: 2.9 Nm 5-3-26 3 Dimensions VPA4150-Bottom ported SA VA SA 4

Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no. Size 25 32 40 50 l 18.2 22.2 26.2 32.2 Size 25 32 40 50 Part no.

Description Material 1 Body Aluminum die-casted 2 (B) 4 (A) 2 Spool assembly Aluminum/FKM e 3 Plug (For the -X1) Steel 1 High Speed Pilot Operated Solenoid Valve DXT1215 Series How to Order Valves DXT1215 T 5 Wm U 01 N X1 w y e r t u q q Coil type w Rated voltage e Electrical entry M8 connector1 T With power-saving circuit 5 24 VDC Wm WO With straight connector cable Without connector cable

) Q R Cooling water outlet 87 G (H) K J Cooling water inlet S T 2 x 2 x U Mounting holes D N Drain C (A) B (M) W Rc (mm) B C D E F G H J K L M N P Q R S T U V W Y Z 473 ZA HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 Model A 360 570 948 1354 1612 2112 1724 1 2 3 4 1 2 1 2 3 4 3 4 3 4 3 4 1 2 1 2 3 4 395 10 10 12 18 18 18 18 4.5 4.5 4.5 6.0 6.0 6.0 8.0 94 94 150 139 139 139

K (3.3) D 4-G through R + Clamp stroke X Z C 0.2 2 x 4-H counterbore Q + 2 x Clamp stroke + 0.15 + 0.05 2-3.3 depth 3 K A P Both ends tapped style: MKA A thread (mm) A B Model MKA MKA50 MKA63 32 40 10 M6 x 1.0 14 M8 x 1.25 18 M10 x 1.5 R + Clamp stroke (Basic) (mm) Q A G I J S T B H K L O U C P V D E R X F Yh9 Z Model 0.1 0.2 MKB32 1 8 0 0.15 0.15 31.5 9 depth 7 M10 x 1.5 93.5 71.5 45 5.5

T2 = [s] L 0.5 V (T1 + T3) V Duty ratio: Ratio of T to T6 T T6 x 100 T = T1 + T2 + T3 + T4 T4 varies depending on the motor type and load. The value below is recommended. = 0.1 + 0.90 + 0.1 + 0.05 = 1.15 [s] 2000 T4 = 0.05 [s] 1000 mm/s2 3000 mm/s2 Step 3 Check the allowable moment. 1500 5000 mm/s2 Refer to Dynamic Allowable Moment graphs (Pages 127 and 128).

A44 PLC Terminal conduit 12V 100V, 200V Relay, PLC DIN terminal P P P P P P A59W F59 F5P J51 J59 Diagnostic indication (2 color) Grommet p p p p 3 wire (NPN) 5V, 12V 24V IC 3 wire (PNP) Grommet P P P P 100V, 200V 2 wire 12V P P G39 K39 5V, 12V 3 wire (NPN) IC Terminal conduit 12V 2 wire P P P P P P P P P P F59W F5PW J59W F5BA F5NT F59F Relay, PLC p p p p p p 3 wire (NPN) 5V, 12V IC Diagnostic

5 Port Air Operated Valve Series VFA3000 How to Order Thread type (Including pilot port) Nil Rc G NPT NPTF Port size (P, A, B port) F N T 01 02 1 8 1 4 R1, R2 port are 1/8. Option F Foot bracket Mounting bracket are supplied, but unattached.

Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.

P-80 (YG) 2nd printing June, 2002 D-DAD P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.

Note 3) Value for quick response type Symbol 2 position single 3 position closed center 3 position exhaust center 3 position pressure center 2 position double (Double solenoid) 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) Manifold Specifications Piping specifications Note 4) 1 station weight (g)