SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-M-01-A1"

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: 01 (Rc1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment

Actuation: 1 (2-Position Single), Electrical Entry: L (L-type Plug Connector), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: E (Push-turn Locking Lever Type), A,B Port: 01 (1/8), Thread Type: N (NPT)

Actuation: 1 (2-Position Single), Electrical Entry: L (L-type Plug Connector), Lead Wire Length: 3 (300mm), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: T (NPTF)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes), Flow Direction: R (Right to Left)

Model: 31, Orifice: 1 (1.5mm), Style: 4 (COM, Single Unit), Option: M (SS, Seals: FKM, Class B, Oil-free), Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: L (w/Light), Rectifier: None (for DC or AC Class H Coil)

Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)

Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: N (NPT)

Function: 2 (Normally Open), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: N (NPT)

Function: 2 (Normally Open), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)

Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8)

Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)

Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)

Nozzle Diameter: 10 (ø1.0mm), Vacuum Pressure: L (-48 kPa), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8)