SMC Corporation of America
Elite Part Number Search
Search Results "CQ2B20-5+5DM-XC10"

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: -, Bore Size: 12mm, Stroke: 5mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: F7NV--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

: M9PV, Lead Wire Length(m): 5, The number of the switches: 1, Type of Auto Switch Mounting: Standard, Type of Mount Support: Through-Hole / Both Ends Tapped Common (Standard), Rod Tip Shape: Male rod end, Custom-made Specifications: None

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches