Refer to page 23 for ordering coil only. DIN type is available with class B only. Refer to Table (3) for available combinations between each electrical option (S, L, Z) and rated voltage. Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.
100 125, 150, 175, 200 M L MGQ 20, 25 MGJ MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 M L MGP MGQ OUT(N) IN(N) Theoretical Output (N) Bore size (mm) MGG Operating pressure (MPa) Rod size (mm) Piston area (mm2) Operating direction 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 MGC Made to Order Specifications (For details, refer to pages 1829 to 2021.) 113 102 90 79 68 57 45 0UT 34 23
Note) AS-FP Metric size Inch size Meter-out Meter-in 0 1 01 02 23 2 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 03 05 07 09 11 13 AS-FM 04 06 08 10 12 AS-D AS-T With One-touch fitting ASP Thread type M3 Port size Note) For applicable tubing O.D. selection, refer to the Model on page 484. Use 1/8" tube.
AS-D Bore size AS-T 1 8 1 4 3 8 1 2 U01 Uni Uni Uni Uni U02 U03 U04 ASP ASN Needle Valve/Flow Rate Characteristics Note) The flow rate characteristics are representative values.
Vacuum digital pressure switch unit (ZSE3) Solenoid valve rated voltage 21 22 23 24 2 outputs/without analog output 2 outputs/with analog output 1 output (with trouble detection)/without analog output 1 output (with trouble detection)/with analog output Caution 1 Note) 100 VAC 50/60 Hz 110 VAC 50/60 Hz 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Air operated (K6, K8, J3, J4, D3, D4) D 3 Note) Surge
(Type 20 manifold) 10 23 5 M 1 M3 SYJ3 Body ported Base mounted (4 port) 2 10 SYJ3 33 5 M (Manifold use only) Base mounted (5 port) SYJ3 43 M 2 5 10 Clean series 4 port Port size Coil specifications Manual override Nil Standard With power saving circuit <24, 12 VDC only> Nil: Non-locking push type Nil: Without sub-plate T Power saving circuit is not available in the case of "W" type.
8 10 8 6 10 4 6 4 6 Elbow Straight Elbow Note) OUT side Mounting position IN side Straight Elbow Straight Elbow Note) OUT side Mounting position 1 2 3 4 5 6 7 8 9 M 1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations Fitting type Symbol Fitting type Symbol 1/4 5/16 3/8 5/16 1/4 3/8 5/32 1/4 5/32 1/4 07 08 09 10 11 12 19 20 21 22 23
How to Order AD402 04 A D Semi-standard symbol: When plural options are required, indicate them in alphanumeric order.
Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)
MXY MTS Theoretical Output (N) Operating pressure (MPa) Cylinder bore (mm) 6 8 12 Piston area (mm2) 0.2 6 10 23 0.55 15 28 62 Magnetic Holding Force (N) 0.5 14 25 57 0.4 11 20 45 0.3 8 15 34 28 50 113 Made to Order Specifications (Refer to pages 1955 to 2021 for details.)
S Couplers Series KK Specifications K M Fluid Air, Water KK2: 100 kPa to 1 MPa KK3: 90 kPa to 1 MPa KK4/6: 0 to 1 MPa H Operating pressure range Note) KK Proof pressure 1.5 MPa Air: 5 to 60C Water: 5 to 40C (No freezing) Series KK2 D Ambient and fluid temperature MS Plating, Sealant Electroless nickel plated (copper-free and fluorine-free application), With male thread sealant LQ Note) Do
Output specifications ZSE ISE 21 NPN open collector 2 outputs without analog output ZSP 22 NPN open collector 2 outputs with analog output (1 to 5 V) PS Positive pressure ISA ISE3 PSE Vacuum ZSE3 IS ISG Suffix Nil None ZSM D For replacement with ZX series Note 3) Compliant with piping specifications OX and OXY only.
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
Direct Operated 2 Port Solenoid Valve Series VXE21/22/23 For Air/Single Unit How to Order (Single Unit) Construction Dimensions For Air For Water For Oil Specifications Model Applications VXE 2 21 01 0 1 G 5 DC VXE2 VXED2 VXEZ2 Bracket Model Refer to Table (1) shown below for availability.
Series VXK21/22/23 Direct Operated 2 Port Solenoid Valve with Built-in Y-strainer For Air/Single Unit How to Order (Single Unit) Specifications For Air For Water For Oil For Steam Dimensions Construction VXK 2 21 01 VXK 2 21 01 1 G 0 0 1 G R 1 5 AC DC Model Refer to the Table (1) shown below for availability. Bracket Orifice size Refer to the Table (1) shown below for availability.
Add to Cart SMC SX3000-75-1A blanking plate, SS5Y3 MANIFOLD SY3000*** $2.66 + Add to Quote Add To Cart Add to Cart SMC SY3000-23
Body Size: 40, Model Type: A (Filter Regulator + Lubricator), Thread: N (NPT), Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.
Body Size: 40, Model Type: A (Filter Regulator + Lubricator), Thread: N (NPT), Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.
Body Size: 30, Model Type: Air Filter + Regulator + Lubricator, Thread: N (NPT), Port Size: 02 (1/4), Float Type Auto Drain: D [N.O.
Body Size: 30, Model Type: Air Filter + Regulator + Lubricator, Thread: N (NPT), Port Size: 02 (1/4), Float Type Auto Drain: D [N.O.