ACT Controller Installation 10 4.1 Installation 10 4.2 Check of the Communication Port 10 4.3 Communication Setting 11 4.4 Functions of Each Mode 12 -1No.JXC-OMX0002 Controller Setting Kit 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Dew point indicator color and humidity of air (1) Bluish Pinkish Bluish --Relative humidity approx. 10% or less Pinkish --Relative humidity approx. 50% or higher (2) Greenish Yellowish Greenish --Relative humidity approx. 10% or less Yellowish --Relative humidity approx. 50% or higher *1. It takes time for the color of the dew point indicator changes. *2.

S: Effective sectional area (mm Air temperature() -20 -10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 SYJ500*-OMJ0001-A -- TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

D-S79# D-S99# D-S99V# D-S7P# D-S9P# D-S9PV# D-T79#(C) D-T99# D-T99V# Lead wire orientation In line Perpendicular In line Perpendicular In line Perpendicular Wiring 3-wire 2-wire Output NPN PNP Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5/12/24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current

When used with tubing other than those from SMC, due to their properties, the products listed below are not subject to warranty. 2M (2) When using fittings other than those from SMC, be certain to confirm that operating conditions are such that no problems will arise. 10 3.

S: Effective sectional area (mm Air temperature() -20 -10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 No.SYJ700*-OMK0001-A -6- TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

Common wiring Common Connector Assembly for Manifold Socket Caution Insert the socket into the connector (below COM indicator) of the neighboring solenoid valve. 10 SX3000-OMM0002-B SX3000/5000/7000 Series Specific Product Precautions 3 Be sure to read before handling.

Panel mounting 10 7. Troubleshooting 11 8. Dimensions 12 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

External Pilot Piping of pilot port [12(P1), 10(P2)] P1 and P2 piping should be as follows according to the model. Caution Port VND0D VND02D 12(P1) External Pilot Bleed port 10(P2) Bleed port External Pilot Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention.

-10- -11#1 -11-11- Revision A Format change and content review B Drawings update 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2019 SMC Corporation All Rights Reserved

Panel mounting 10 7. Troubleshooting 11 8. Dimensions 12 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

(Tightening torque 0.6 to 0.8Nm) Dipswitch ON 1 2 1 2 3 4 5 6 7 8 9 10 SW40 SW20 SW10 SW08 SW04 SW02 SW01 BS4 BS2 BS1 Hold/Clear Terminating resistor Setting at the time of shipment 1 2 1 2 3 4 5 6 7 8 9 10 Node address: 1 Baud rate: 10Mbps Hold/Clear: Clear Terminating resistor: disable Setting of node address Node address SW40 SW20 SW10 SW08 SW04 SW02 SW01 1 OFF OFF OFF OFF OFF OFF ON 2

S: Effective sectional area (mm Air temperature() -20 -10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 SYJ5000-OMJ0001-A -6- TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.

Operation in a low temperature condition It is possible to operate a valve in extreme temperature, as low as -10 . Take appropriate measures to avoid freezing of drainage, moisture etc. in low temperature. 7. Mounting orientation Mounting orientation is free. Design / Selection 3.

Warning Warning Caution External Pilot Pilot port 12(P1) and 10(P2) piping P1 and P2 piping should be as follows according to the model. Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention. Caution Mounting 1. Do not apply external force to the coil section.

10%Power supply voltage 24 VDC type: 0.12 A or less Note 6)Power supply voltage 12 to 15 VDC type: 0.18 A or lessSet pressure ?13.3 kPa?101 kPa?1.3 to ?

10%Power supply voltage 24 VDC type: 0.12 A or less Note 6)Power supply voltage 12 to 15 VDC type: 0.18 A or lessSet pressure ?13.3 kPa?101 kPa?1.3 to ?

10%Power supply voltage 24 VDC type: 0.12 A or less Note 6)Power supply voltage 12 to 15 VDC type: 0.18 A or lessSet pressure ?13.3 kPa?101 kPa?1.3 to ?

10%Power supply voltage 24 VDC type: 0.12 A or less Note 6)Power supply voltage 12 to 15 VDC type: 0.18 A or lessSet pressure ?13.3 kPa?101 kPa?1.3 to ?