C + Stroke E B + Stroke XAH7 depth XL A + Stroke (mm) MLGPM, MLGPL common dimensions Bore size (mm) Standard stroke (mm) B C DA FA FB G GA GB GC H HA IA IB IC ID IE 10 14 14 100 44 16 12 44 54 120 M6 34 52 6.5 14 4 40 25, 50, 75 100, 125, 150, 175 200, 250, 300, 350 11 12 14 107 44 20 16 47 64 148 M8 35 64 6.8 19 50 7 13.5 16.5 115 49 20 16 50 78 162 M10 38 77 7.5 19 63 16.5 6.5 Bore size
L 26 H 2 065500 mm/s2 27 L 28 1 030 10% 29 1 030 10% 30 1 0255 mm/s 31 1 030 10% 32 H 2 065500 0.01mm 33 L ID2 3453 ID1 ID3 5473 ID1 ID4 7493 ID1 ID5 94113 ID1 012 38 - 122 IF IN Data IDIF ID=1 ID=1 bit 7 6 5 4 3 2 1 0 I_Address 32 33 1 LEC1ON 0OFF 2 LEC0OFF 1ON 3 1 LEC1ON 0OFF 4 LEC1ON 0 0OFF 123 IN Data bit 7 6 5 4 3 2 1 0 I_Address 0 ALARM READY 1 2 3 1 0 Bit1
MHR MHQJ2-25S 14 25 49 643 Single acting MHQJ2-10C 4 MHK 10 7.8 90 6 MHQJ2-16C 16 26 181 Normally closed MHS 10 MHQJ2-20C 20 33 342 14 MHQJ2-25C 25 49 643 MHC Note 1) Values at the pressure of 0.5 MPa.
30 60 Allowable thrust load 10 10 20 25 40 Port location Side ported or Axial ported Port size (Side ported, Axial ported) M3 x 0.5 M5 x 0.8 Angle adjustable range Note 2) 0 to 90 Note 1) Make sure to operate within the speed regulation range.
10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 84 90 98 116 126 146 159 170 204 215 16
Blank plate with 2 screws and gasket L 12.5 (Pitch) 5.25 7.5 25 35 5.5 1.25 VVQ100-10A-2 Plug lead unit (VV3Q12) for manifold L Size Dimensions L=12.5n+10.5 10 135.5 9 123 8 110.5 7 98 6 85.5 5 73 4 60.5 3 48 2 35.5 1 23 No. L size 19 248 18 235.5 17 223 16 210.5 15 198 14 185.5 13 173 12 160.5 11 148 No.
285.5 11 142 191 211 237.5 248 16 192 241 261 287.5 298 12 152 201 221 250 260.5 15 182 231 251 275 285.5 L1 L2 (L3) (L4) (L5) *SG Type: L2=10n+68 (L3)=L3(Std.)+25 (L4)=L4(Std.)+25 (L5)=L5(Std.)+25 11 Series VQ100 Non Plug-in Unit Manifold VV3Q12 Phillips/ordinary round head screw M1.74 L1 5 L2 3 Manual override 2-3.2 Mounting hole 10.8 3.5 8.9 P E 28.7 11 P E 26.5 33.8 44.8 4-M5 (P,E port
] 15 [0.10] 15 [0.10] 7.3 [0.05] 7.3 [0.05] 7.3 [0.05] 0.00 0 1.3 [5] 2.6 [10] 4.0 [15] 5.3 [20] 7.9 [30] 9.2 [35] 11 [40] 12 [45] 6.6 [25] 0.00 0 1.3 [5] 2.6 [10] 4.0 [15] 5.3 [20] 7.9 [30] 9.2 [35] 11 [40] 12 [45] 13 [50] 15 [55] 16 [60] 6.6 [25] 0.00 0 0.1 [0.5] 0.3 [1] 0.4 [1.5] 0.5 [2] 0.8 [3] 0.9 [3.5] 1.1 [4] 1.2 [4.5] 1.3 [5] 0.7 [2.5] Flow rate gal/min [L/min] Flow rate gal/min [
TB W Counterbore depth TC Inner cover holding screw Note) (mm) A 8 12 B 10.5 16 C 6.4 10.2 E 4 6 ED 9.5 13 EK 4 6 F 12.5 25 G 10 9 H 45 75 HA 23 39 HI 23 39 HL 37.6 63.3 HP 44 73.5 J M6 x 1 M10 x 1.5 JK 10 12 K 21 20 L 67 90 LD 5.6 9.2 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 LW 69 115 MM M4 x 0.7 M6 x 1 M 6 8 N 4.5 7.5 P 5/16-24 UNF 7/16-20 UNF PA 25 50 PB 60 100 PC 10 12 Q 112 147 QW 48
In the case of -X80, VF3240(Pilot valve) will be mounted. 4-10-10
ZR 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.1 0.2 0.3 0.4 0.5 0.6 ZM Supply pressure (MPa) Supply pressure (MPa) ZMA Flow Characteristics Flow Characteristics Supply pressure: 0.4 MPa Supply pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 ZH 70 70 60 60 ZU 50 50 40 40 30 30 ZL 20 20 10 10 ZY 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220
-3A Body ported type (SYJ5 2) Base mounted (SYJ5 4) Phillips' head screw M2.5 7, Non-gloss nickel plating Phillips' head screw M2.5 25, Non-gloss nickel plating Blank plate SYJ500-10-2 Gasket DXT200-9-1 Applicable base sub-plate SS3YJ5-21R SS3YJ5-40 SS3YJ5-41 SS3YJ5-40R SS3YJ5-41R Manifold base Gasket DXT200-9-5 Gasket DXT200-9-1 Gasket DXT170-29-1 SYJ500-10-1A Phillips' head screw M2.5 7
Load Rotary actuator Flexible coupling Bearing Fig. (9) Flexible coupling 28 - Piping and operating direction Fig. (10) shows piping ports of the rotary actuator. Table (9) shows the port size. Table (9) Port size Size Port size 30 M5 50 Rc1/8 63 Rc1/8 B Port 80 Rc1/4 100 Rc3/8 A Port Fig. (10) Port location A fixed throttle is installed inside the actuator port.
AXT632-106A-1 AXT632-106A-2 Note) Each of the above part numbers is for two screws, which are to be ordered by 10 units. Order is accepted in 10 units.
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 ASG22F-M5 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 M5 x 0.8 6, 10, 16, 20 R1/8 20, 25, 32 R1/4 20, 25, 32, 40 R3/8 40, 50, 63 R1/2 63, 80, 100 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure 0.1 MPa Ambient and fluid temperature 5 to 60C (No freezing) Number of needle rotations 10 turns
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 5, 10, 15, 20, 25, 30 20, 25, 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 50, 63, 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50 Intermediate strokes are available as a special order.
16 26 235 MHZ MHK2-25D 25 14 19 33 440 MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed L1 MHF MHK2-16S 16 23 6 14.6 20.6 114 L2 L1 MHK2-20S 20 34 10 16 26 237 MHL L2 Series MHK2 MHK2-25S 25 58 14 19 33 443 Series MHKL2 MHK2-12C 12 12 4 9 13 76 MHR MHK2-16C 16 25 6 14.6 20.6 115 MHK MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 MHS Series MHKL2/Long Stroke Type Made to
Y (EX245-DX1)(EX245-DY1) Y 2 PCA-1557785 Y (2M12 M12) A A A . 10-2 Y (PCA-1557785) 64 No.EX-OMU0020CN PCA-1557798 Y (2M8 M12) A . 10-3 Y (PCA-1557798) 65 No.EX-OMU0020CN 10.3.
16.9 20 10 2 190 22.8 50 10 18.8 20 10 3 190 24.4 47 10 20.4 15 10 7 190 28.7 31 10 24.7 15 10 Operating range m: The value in which the auto switch operating range Lm is converted to axis rotating value.