Note 2) At filler inlet oil concentration 24ppm {30mg/m' (ANA)).
How to Order Rated pressure range ISE20B 0 to 1 MPa ISE20B M5 L M For positive pressure For vacuum/ compound pressure ZSE20B L M M5 q w e r t y u q Rated pressure range w Output specification e Unit specification ZSE20B 0 to 100 kPa ZSE20BF 100 to 100 kPa Symbol Description Symbol Description Nil Units selection function*1 M SI unit only*2 P Units selection function (Initial value psi)*1
(See I/O Configuration (page 19) for details.) -15No.EX-OME0014-F Diagnosis information Diagnosis information of the SI unit is composed of 6 bytes standard diagnosis information and 7 bytes SI unit status information, 13 bytes in total, as specified in PROFIBUS DP.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
23 20 11.5 3 2.6 2(Mounting holes) 11 (Non-locking) Manual override 4-Rc(PT)1/8 33.5 46.5 46.5 21.8 (Bleed port) With filter (80 Mesh) 5-M5 X 0.8 (Piping port) (Piping port) 21.5 R1 P 8.5 6 6 R2 15 1.8 (Bleed port) With filter (80 Mesh) 217 17 21 45.5 24 32 3 position closed center/exhaust center/pressure center: SYJA5 20-M5 3 position closed center/exhaust center/pressure center: SYJA5
12VDC 9-Others How to Order Pilot Valve Assembly SF4 50 SDcifictions Applicable plug connctor assembly for L&M type plug connector Connector assembly: DXT1 70-80'lA-r( Connector assembly with coven DXT170-12FA-* Voltage Manualoverride 1'100vAc 5q,50 Hz 2.
temperature oC *Note3 Regulator construction (about Type V) Relief type Port size 1/8 1/4 Type M 0.6 Mass kg Type V 0.9 * Note 1.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T Base size A, B Port size 5 3 4 6 1 Symbol 04 Port size VVPA450 VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
7.3 D C B A PD port size Metric size: Rc1/8 Inch size: NPT1/8 Supply Port Dimensions [mm] Dimensions [mm] N C4 4.7 C6 4.7 N3 4.7 N7 7.3 A B C D E F ZHP63BM 26 45.8 63 68 12.5 33.8 ZHP80BM 28 57 80 85 18 41.8 ZHP63UM 26 63 66 5 20.3 ZHP80UM 26 80 83 5 20.3 Circuit Adapter Dimensions (by Mounting Style) [mm] G H J K L M ZHPmmmA-mmS 25.7 22.6 5 13 M8 ZHPmmmB-mmS 27.1 21.2 6 17 M10 ZHPmmmC-mmS
Standard lead wire length is 0.5 m. Add L to the end of the part number when 3 m is desired, M when 1 m, and Z when 5 m. Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
SMC Corporation R&D Center Product Development Division-6 Address: 4-2-2, KINUNODAI,TSUKUBAMIRAI-CITY , IBARAKI-KEN 300-2493, JAPAN Phone:+81-297-52-6 Fax:+81-297-20-5007 E-mail:kaihatsu_6_g3@smcjpn.co.jp Notice: The content of this manual can be revised without a previous notice.
H4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 400/100 600/150 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
Switch No. 0 (Default) 1 2 3 4 5 6 7 8 9 Slower (Speeds up gradually.)
This can cause an injury or accident. 6. Do not put hands, etc. in between the air gripper fingers or attachments. This can cause an injury or accident. 7. When removing the air gripper, first confirm that no workpieces are being held and then release the compressed air before removing the air gripper.
MH*-OMU0057 / / MHZ2-10* MHZ2-16* MHZ2-20* MHZ2-25* MHZ2-32* MHZ2-40* 1. 1-1. 2. 2-1 2-2 2-3 2-4 2-5 2-6 2-7 3. 3-1. 3-2. 3-3.
(Step change) Changes in the load. 23 - 6. Construction No.
Give enough curvature to the lead wire not to have excessive force when it is fixed. 6. Fluid containing foreign matters and oil will cause malfunction and sealing failure.
1 Depth 6 32 42 3 57 52 47 147 98 1/2 37 97.5 6 82.5 M6 x 1 Depth 6 32 42 3 57 52 47 147 98 1/2 37 99.5 10.5 06 10 M6 x 1 Depth 7.5 39 50 0 77 74 59 155 128 143 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular
M L Bearing type Compact type Slide Bearing Ball bushing bearing Bore size/Stroke (mm) Standard stroke 10, 20, 30, 40, 50 10, 20, 30, 40, 50 Bore size 6 10 Auto Switch Specifications (Refer to the WEB catalog for detailed specifications and auto switches not in the following table.)
E J E C T O R (N)ZM D I M E N S I O N S W I T H VA C U U M S W I T C H D I M E N S I O N S B A S I C T Y P E N O Z Z L E D I A M E T E R 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm T Y P E 2 Body Ported 4 Manifold Type-Common SUP 6 Manifold Type-Individual SUP S U P P LY P R E S S U R E H 5 Bar M 3.5 Bar P O R T T H R E A D Nil PT* Remove (N) when ordering T NPTF S W I T C H E S Model Standard Supply