SMC Corporation of America
Elite Part Number Search
Search Results "CKZT50TN-90-X167USB"

This is the maximum cable length. 3m 5m 5m 5m 5m 5m 11 - Conditions of environment Item Specifications Applicable ambient temperature 040(No freezing) Applicable ambient humidity 90%RH or less (No condensation) Atmosphere No corrosive gas, flammable gas, oil mist, or particles.

This is the maximum cable length. 3m 5m 5m 5m 5m Conditions of environment Item Specifications Applicable ambient temperature 040(No freezing) Applicable ambient humidity 90%RH or less (No condensation) Atmosphere No corrosive gas, flammable gas, oil mist, or particles.

VXF21A VXF22A VXF23A VXF24A VXF27B VXF28B VXF25(A,B) VXF26(A,B, C,D) Product number Orifice size mm 22 28 44 53 70 80 90 100 Air Fluid Minimum operating pressure Maximum operating pressure MPa 0.03 0.1 MPa 0.7 Fluid temperature -10 (Non-freezing) to 60 Ambient temperature -10 to 60 Coil insulation type Class B Enclosure IP65 Alloable voltage fiuctuation 10% of rated voltage AC VA 10 7

Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing (4) and a terminal block (3). Maintenance parts Refer to SMC catalog for the part No. of the coil assembly and DIN terminal connector.

Locking type (Tool required) Push down the manual override button with a small flat head screwdriver until it stops, and turn it clockwise 90 to lock it. Turn it counterclockwise to release it. Locking type (Manual) Push down the manual override button with a small flat head screwdriver or with your finger until it stops, and turn it clockwise 90 to lock it.

Warning Push-turn locking slotted type [D type] While pressing, turn in the direction of the arrow (90 clockwise). If it is not turned, it can be operated the same way as the non-locking type. Caution When you operate the D type with a screwdriver, turn it gently using a watchmaker's screw driver.

Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13 48 39 4.6 12 11.5 52 28 2.5 depth 8.5 2 Approx. 45g LFE14 48 39 4.6

more/2.5 mA or more 17 V or more/2.5 mA or more ON voltage/ON current (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) 7 V or less/1 mA or less OFF voltage/OFF current 7 V or less/1 mA or less (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) LED display Green LED (lights up during ON time) Weight EX510-DX 1: 90

more/2.5 mA or more 17 V or more/2.5 mA or more ON voltage/ON current (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) 7 V or less/1 mA or less OFF voltage/OFF current 7 V or less/1 mA or less (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) LED display Green LED (lights up during ON time) Weight EX510-DX 1: 90

more/2.5 mA or more 17 V or more/2.5 mA or more ON voltage/ON current (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) 7 V or less/1 mA or less OFF voltage/OFF current 7 V or less/1 mA or less (Between input terminal and (Between input terminal and 0 V for sensor) +24 V for sensor) LED display Green LED (lights up during ON time) Weight EX510-DX 1: 90

Table 3-1 Amount of radiation and required ventilation Required ventilation amount m3/min Heat Differential temp. of 3 oC Differential temp. of 6 oC Radiated Model between inside and between inside and kW outside of installation area outside of installation area HRSE012-AApprox. 2 40 20 HRSE018-AApprox. 4 70 40 HRSE024-A-20/23 Approx. 5 90 50 3.2 Installation HRSE Series 3-4 HRX-OM-R039 Chapter

acceleration/deceleration [mm/s2] 9800 Positionimg repeatability [mm] 0.01 Lost motion [mm] *4 0.05 or less Thread size [mm] Lead [mm] 50 25 10 25 Ball screw specifications Shaft length [mm] Stroke + 284.5 Lead [mm] 50 25 10 Impact/Vibration resistance [m/s2] *5 50/20 Actuation type Ball screw Guide type Linear guide Operating temperature range [] 5 to 40 Operating humidity range [%RH] 90

Nozzle removal 3) Set the removal tool to the emitter assembly, then rotate 90 degrees counterclockwise.

The angle adjustment range of the bracket is 50 degrees in direction A, and 90 degrees in direction B. 2) Installation without bracket Direction B 90o Direction A 50o M5 If a bracket is not used, install the product using the M4 screw holes (depth: 6 mm) on both sides of the body. Be sure to secure both sides of the body when fixing this product.

Changing the entry direction After separating the terminal block (2) and housing (3), the cord entry can be changed by attaching the housing (3) in the desired direction (4 directions at 90 intervals). When equipped with a light, be careful not to damage the light with the cords lead wires. Precautions Plug in and pull out the connector vertically without tilting to one side.

While down, turn clockwise 90 to lock it. Turn it counterclockwise to release it. Do not torque it more than required in case to operate a lock type manual.

. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20 DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85 FINLAND / (358) 9-859 580 PORTUGAL / (351) 2 610 89 22 FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100 GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700 GREECE / (30) 1342 6076 SWITZERLAND / (41) 52-396 3131 HUNGARY / (36) 1-371 1343 TURKEY / (90) 212 221 1512 IRELAND / (353) 1-403 9000

O-ring (New) O-ring (Used) Gasket (New) Gasket (Used) Element (Used) Element (New) Case AMD80, 81, 90, 91, 100 y Replacement Parts e Element r Seal t Seal y Gasket u O-ring (Material: NBR) (Material: NBR) (Material: V#6500) (Material: NBR) IN OUT Model applicable filter Kit no. Kit no. Kit no. Kit no. Kit no. Qty. Qty. Qty. Qty. Qty.