distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1
(H) Threaded type Pilot port Rc 1/8 (NPT 1/8) N M C A B D Double acting valve P Pilot port LQ1 integral fitting 1/8 (3), (4) Rc 1/8 (NPT 1/8) R Pilot port Sensor (breathing) port Rc 1/8 (NPT 1/8) Pilot port LQ1 integral fitting 1/8 (3), (4) Rc 1/8 (NPT 1/8) Pilot port A B SMC A B SMC LVQ S-S Dimensions (N.O. valve, double acting valve) 2 1 (mm) A B C D E F G H J K L M N P Q R W Model LVQ2
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K N.C.
Point of application L Operation conditions Operation conditions Operating pressure P (MPa) Operating pressure P (MPa) Work piece weight m (Kg) Work piece weight m (Kg) Work piece quality x (Qty.) Work piece quality x (Qty.)
Point of application L Operation conditions Operation conditions Operating pressure P (MPa) Operating pressure P (MPa) Work piece weight m (Kg) Work piece weight m (Kg) Work piece quality x (Qty.) Work piece quality x (Qty.)
Total stroke time t Stroke L Stroke mm Speed d% d% Speed at the end Stroke Speed at the end u Time s SOL: ON (OFF) VI Table of Contents Series SV Manifold Variations P. 2 Valve Manifold Common Specifications Serial Wiring Manifold specifications Decentralized Serial Wiring P. 5 Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 IP67 protection Applicable
Class 3 ground Ground resistor 100 or less Command pulse (MAX.225/kpps) PULS SIGN P Incremental encoder SIGN CLR P Deviation counter clear signal (active high) 2CN PG CLR P Be certain to treat the shielding wire terminals.
For Water 250.0 VXB215C F(H) 200.0 Flow rate Q [L/min] VXB215B E(H) 150.0 VXB215A D(H) 100.0 50.0 0.0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 Pressure differential P = (P1 P2) [MPa] How to read the graph When a water flow of 50 L/min is generated, P 0.1 MPa for the VXB215A D(H). 13 Flow Rate Characteristics VXB Series For Saturated Steam 1.0 Upstream pressure of valve P1 0.9 0.8 1.0 MPa Downstream
SYJ7000-21-1A 1 pc. 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) 3 position exhaust center 3 position closed center (A) 4 (A) 4 (B) 2 (B) 2 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) 5 (R1) The asterisk denotes the symbol for assembly.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
. 10-12-8 P . 10-12-30 P . 10-12-18 P . 10-12-27 10-12-1 2 Achieve rationalization of production lines with position feedback Stroke reading cylinder Measurement is possible throughout the full stroke range.
Thread: N (NPT), Seal: None, Options: P (Scale Plate Pressure Unit: Both MPa and psi)
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -
Size: 5, Standard Dew Point: -20°C, Type: Standard, Thread: N (NPT), Port Size: 01 (1/8), Accessory: None (Standard), Option: P (Fitting for Purge Air Exhaust)
Size: 3, Standard Dew Point: H (-15°C), Type: Standard, Thread: N (NPT), Port Size: 01 (1/8), Accessory: None (Standard), Option: P (Fitting for Purge Air Exhaust)
Size: 3, Standard Dew Point: -20°C, Type: Standard, Thread: NPT, Port Size: 1/8, Accessory: None (Standard), Option: Fitting for Purge Air Exhaust
Size: 5, Standard Dew Point: -20°C, Type: Standard, Thread: NPT, Port Size: 1/8, Accessory: None (Standard), Option: Fitting for Purge Air Exhaust
Size: 3, Standard Dew Point: -15°C, Type: Standard, Thread: NPT, Port Size: 1/8, Accessory: None (Standard), Option: Fitting for Purge Air Exhaust