Before disposing of any IoT devices, delete stored data or physically destruct media to prevent any misuse of the data. 111 No.EX##-OMY0004 Revision history Issued 19/08/2020 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part
Terminal Setting Contrast LCD9(08) 4 Bright LCD5(04) 2 Key Sound 5(04) 2 PowerSave 5(137 10) 1M Default Password Change 48 0 -47No.EX-OML0010CN-C Password Change() Password Change A,BZ, 0,19 "Wrong Password" -48No.EX-OML0010CN-C "PASS""WORD" "PASS" "*" "WORD" () -49No.EX-OML0010CN-C No.
With body cover window No.DIG-31900-OM002 73 Drawing No.DIG-31900-OM002 74 No.DIG-31900-OM002 75 No.DIG-31900-OM002 76 No.DIG-31900-OM002 77 No.DIG-31900-OM002 78 No.DIG-31900-OM002 79 No.DIG-31900-OM002 80 No.DIG-31900-OM002 81 No.DIG-31900-OM002 82 No.DIG-31900-OM002 83 Revision history A 26/09/2005 Address change B 30/03/2006 Add the How to Operation C 28/11/2006 Add the ATEX item D 28/08
. -12No.EX-OME0015-F Power supply wiring (Power supply for solenoid valve) MSTB2, 5/2-STF-5, 08 connectors manufactured by Phoenix Contact are attached to the SI unit for mounting on the cable. The power supply connector for the solenoid valve is wired in the following way. The connector screws should be tightened securely with a tightening torque of 0.5 to 0.6 Nm.
Fi l t rat i on rat i ng0. 01 m ( Fi l t rat i on ef f i ci ency99. 9% ) O ut l et oi l m i st concent rat i on: 0. 08 ppm ( Fi l t er i nl et : 24ppm ) Fl ui d ot her t han com pressed ai r Ai r pressure m ore t han 1. 0 M Pa** and 0. 05M Pa* or l ess Fol l ow i ng envi ronm ent s l ead to cause breakage.
Fi l t rat i on rat i ng0. 01 m ( Fi l t rat i on ef f i ci ency99. 9% ) O ut l et oi l m i st concent rat i on: 0. 08 ppm ( Fi l t er i nl et : 24ppm ) Fl ui d ot her t han com pressed ai r Ai r pressure m ore t han 1. 0 M Pa** and 0. 05M Pa* or l ess Fol l ow i ng envi ronm ent s l ead to cause breakage.
(Drill through) Note) Dd9 L l d m H B C CJ1 D Cotter pin 3 x 18l 4 x 25l 4 x 35l 0.040 0.076 0.050 0.093 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 10 14 22 32 40 50, 63 80 100 32, 40 50, 63 80, 100 3 4 4 44 60 82 36 51 72 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 4 4.5 5 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CJP CJ2 Note) When
Bore size (mm) Part No. d l Cotter pin d m H B Dd9 L C D (Cut through) Note 1) 3 x 18l 4 x 25l 4 x 35l 10 14 22 32, 40 50, 63 80, 100 32 40 50, 63 80 100 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 36 51 72 4 4.5 5 6 8 11 13 16 17 22 27 32 41 44 60 82 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 0.040 0.076 0.050 0.093 0.065 0.117 3 4
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: T (Pressure Sensor, -100 to 100, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut), 1st Nominal Nozzle
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: 1 LPM , 1 LPM, Max Pressure: 12 PSIG / 827 mbar , 12 PSIG / 827 mbar, Max Vacuum: 19.4 in HgV / -658 mbar , 19.4 in HgV / -658 mbar, Voltage (DC): 12, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
Thomas Oil-less Diaphragm Compressor / Vacuum Pump Flow Rate: .65 LPM , .65 LPM, Max Pressure: 11.1 PSIG / 765 mbar , 11.1 PSIG / 765 mbar, Max Vacuum: 18 in HgV / -608 mbar , 18 in HgV / -608 mbar, Voltage (DC): 3, DC Motor Type: Low Cost, Net Weight: .08 lbs. / .04 Kg Series Configured Datasheet.
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / -14.5 to 14.5 (100 to -100) kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Stations: 08, A,B Port: N7 (ø1/4" One-touch Fitting, Inch), Thread: T (NPTF)
Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ø8), Seal: S (with Sealant)
Handle Position: B (Front), Piping: 3 (IN: Bottom/OUT: Top), Stations: 3 Stations, Fitting: 08 (IN: Straight Ø6, OUT: Straight Ø6), Accessory: A (Pressure Gauge), Option: None, Unit: Z [Name Plate, Gauge & Pressure Switch w/Unit Switching Function (PSI)]
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut), 1st Nominal Nozzle Size
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow