HRS100-A/W-20/40, HRS150-A/W-40 4 h 2 h 1 h 4 min 6 min 10 min 14 min 20 min 30 min 2 min 1 min Operating time 20 s 30 s 10 s Max. 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 5000 6000 7000 10 1500 Current (% for chiller main breaker volume) 123 HRS100/150 Series Specific Product Precautions 5 Be sure to read this before handling
Model Bore size (mm) Gripping moment (Nm) (Effective value) (1) Opening/closing angle (Both sides) Weight (2) (g) Action Model MHC2-10D MHC2-16D MHC2-20D MHC2-25D 39 91 180 311 0.10 0.39 0.70 1.36 10 16 20 25 30 to 10 Double acting MHC2-10S MHC2-16S MHC2-20S MHC2-25S 0.070 0.31 0.54 1.08 39 92 183 316 10 16 20 25 MHC2-16S 30 to 10 Single acting Note 1) At the pressure of 0.5 MPa.
2 2 0.3 0.4 0.4 D0.2 1 1 0.3 200 30 20 10 0 30 20 10 0 30 20 10 Gripping point L mm Gripping point L mm Gripping point L mm 12-8-11 12 Series MHC2/MHCA2/MHCM2 Confirmation of Inertial Moment of Attachment Step 2 Confirm the inertial moment of one of the two attachments.
Work piece mass (kg) Work piece mass (kg) 10 10 5 5 1 1 kg 1 0.25 kg 5 10 20 30 10 20 40 32.5 m/min Transfer speed (m/min) Transfer speed (m/min) 12 m/min Procedure 3 Confirmation of allowable lateral load MIW12 MIS12 1. Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 1.
(mm) Connection threads R Model M Effective area (mm2) Weight (g) A L 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 H04-01 15 4 10 H04-02 14 10 25.1 29.1 21.1 23.1 10 4 10 17 Applicable tubing H06-01 12 25.1 21.1 H06-02 16 29.1 19 17 12 14 6 11 12 14 23.1 24.8 21.1 23.1 24.8 23.1 24.8 25.9 24.1 24.8 25.9 59 Reference dimensions after R thread installation.
/O.D. mm Series Body size 6.5/10 8.5/12.5 5/8 6/9 8/12 11/16 KK3 KK4 KK6 1/8 1/4 1/2 One-touch fitting type Applicable tubing O.D. mm Series Body size 16 8 10 12 4 6 KK3 KK4 KK6 1/8 1/4 1/2 Manufactured by Rectus Series KK13 Series KK13 Applicable hose I.D.
L Type Plug Connector (L) 10-32 Nom (M5) 10-32 Nom (M5) 4 porls g .g 3 1 1 . 8 1 I (300)r I 2.0i (St ) -9 :ions (n 7 6 10 11 12 13 14 'i6 17 18 20 L1 1.40 11.41 (35.s) (46) 2.22 2.& (56.5) (67) 3.O5 3.46 (Be) 3.84 1 4.2S (e8.5) oos) 4.70 (119.5) 512 15.53 (130) (140.5) 5.94 (1511 (161.5) \172) 7.19 7.60 (182.s) (1S3)a.ol (203.5) 8.43 \7t4) 8.84 Q24.5) L2 1.12 {a.r) 1.54 (30) 1.95 (4e.5)2.36
L Type Plug Connector (L) 10-32 Nom (M5) 10-32 Nom (M5) 4 porls g .g 3 1 1 . 8 1 I (300)r I 2.0i (St ) -9 :ions (n 7 6 10 11 12 13 14 'i6 17 18 20 L1 1.40 11.41 (35.s) (46) 2.22 2.& (56.5) (67) 3.O5 3.46 (Be) 3.84 1 4.2S (e8.5) oos) 4.70 (119.5) 512 15.53 (130) (140.5) 5.94 (1511 (161.5) \172) 7.19 7.60 (182.s) (1S3)a.ol (203.5) 8.43 \7t4) 8.84 Q24.5) L2 1.12 {a.r) 1.54 (30) 1.95 (4e.5)2.36
Pressure 50 45 40 3/8" 45 40 35 40 35 Pressure Drop (psid) 30 1" 3/4" 35 Torque (in-lbs) 30 25 30 1" 1/2" 25 1/4" 1/4" RPM 25 20 1/2" 3/8" 20 3/4" 20 15 3/4" 15 15 1/2" 3/8" 10 1" 10 10 2" 1/4" 5 5 5 1-1/2" 0 0 0 0 2000 1000 3000 4000 5000 1000 0 2000 3000 4000 5000 0 10 20 30 40 50 60 70 80 90 Pressure (PSI) Pressure (PSI) Flow (USGPM) Quick Coupling Division 8145 Lewis Road Minneapolis
2 n Different surfaces Different surfaces Same surface Same surface D-A9 D-M9 D-M9W (n 2) 2 15 + 45 10 15 (1) (1) 45 45 + 45 (n 2) (n = 2, 4, 6...)
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
1 Auto Switch Guide Reed Switches/Solid State Switches For Air Grippers (Rotary Actuators) Applicable Auto Switch Auto switch mounting Applicable rotary actuators Applicable air grippers MHZ Auto switch model Electrical entry Size Page Type Size MHF 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ2 MRQ MDSUB
L Type Plug Connector (L) 10-32 Nom (M5) 10-32 Nom (M5) 4 porls g .g 3 1 1 . 8 1 I (300)r I 2.0i (St ) -9 :ions (n 7 6 10 11 12 13 14 'i6 17 18 20 L1 1.40 11.41 (35.s) (46) 2.22 2.& (56.5) (67) 3.O5 3.46 (Be) 3.84 1 4.2S (e8.5) oos) 4.70 (119.5) 512 15.53 (130) (140.5) 5.94 (1511 (161.5) \172) 7.19 7.60 (182.s) (1S3)a.ol (203.5) 8.43 \7t4) 8.84 Q24.5) L2 1.12 {a.r) 1.54 (30) 1.95 (4e.5)2.36
DOC1001322 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before Using the Product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.4 Product Label . 1-3 1.5 Safety Measures . 1-4 1.5.1 Safety instructions for use . 1-4 1.5.2 Personal protective equipment . 1-4 1.6 Emergency Measures. 1
acid) H2SO4: 96% or less p 50 to 140F (10 to 60C) Ozone p Note 2) 50 to 140F (10 to 60C) Ammonium hydroxide NH3: 5% or less NH3: 5% or less H2O2: 20% or less p Note 1) 2) 50 to 140F (10 to 60C) Ammonia hydrogen peroxide solution p Note 2) 50 to 140F (10 to 60C) Sodium hydroxide NaOH: 50% or less p Note 1) 50 to 140F (10 to 60C) Deionized water How to read the table: p: Useable c: Consult
Approx. 1.1 mm Insulator Colours Brown, blue, black, white Sheath Finish O.D. 4 -53No.PF-OMX0007-A Characteristics data Flow rate/Analogue output 0 L/min A 2 B 0 L/min C 2 D Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 3 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range *4 Maximum value of rated flow range PF3A701H 10 L
(mm) Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 7 25 6 32 8 40 8 50 8 D-A9 D-M9/M9W D-A9 D-M9 D-M9W Note) qBMA2-020 wBJ3-1 Note) qBMA2-025 wBJ3-1 Note) qBMA2-032 wBJ3-1 Note) qBMA2-040 wBJ3-1 Note) qBMA2-050 wBJ3-1 5 5.5 5 5.5 6.5 D-B7/B80 D-B73C/B80C 8 10 9 10 10 D-C7/C80 D-C73C D-C80C D-H7/H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C/C80C D-B5/B64 D-B59W
15 0 5 10 15 20 25 0 5 10 15 20 Vertical L7 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 600 600 600 Z 400 400 400 200 200 200 Mep m 0 0 0 0 5 10 15 0 5 10 15 20 25 0 5 10 15 20 L8 Work load [kg] Work load [kg] Work load [kg] Calculation of Guide Load Factor Mounting orientation 1.
. 7-1 7-5 . 7-2 8 C 8-1 . 8-1 8-2 . 8-1 9 K 9-1 . 9-1 9-2 . 9-1 10 L 10-1 . 10-1 10-2 . 10-1 10-3 . 10-2 10-4 . 10-2 11 M 11-1 . 11-1 11-2 . 11-1 11-3 . 11-2 11-4 . 11-2 12 R 12-1 . 12-1 12-2 . 12-1 12-3 . 12-1 12-4 . 12-2 12-5 . 12-2 2 13 S 13-1 . 13-1 13-2 . 13-2 13-3 . 13-2 14 T 14-1 . 14-1 14-2 . 14-1 14-3 . 14-1 14-4 . 14-2 14-5 . 14-3 15
2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 Flow CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Setting/display flow range 0 to 9 ft3 x10-1 Accumulated flow Min. setting/display unit 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/pulse ft3 x 10-2/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse