SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS3-10-101-02"

48.3 44.2 42.8 13.3 21.5 24 7.8 16.2 23 (24) AS221FS-02-04 (S) 4 8.2 AS221FS-02-06 (S) 6 10.4 23.4 32.7 (32.8) AS221FS-02-08 (S) 8 13.2 23.9 33.2 (33.3) 14.2 24 (25) AS221FS-02-10 (S) 10 15.9 26.9 36.2 (36.3) 15.6 25 (26) AS321FS-02-06 (S) 6 1/4 17 (17.5) 13 13.3 10.4 21.8 32.1 36.4 63.1 61.7 57.9 56.5 24.5 28.5 9.3 19.2 47 (48) AS321FS-02-08 (S) 8 13.2 22.7 33 14.2 AS321FS-02-10 (S) 10

Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/

ASD430F-02-08ST R 1/4 36.7 11 7 15 18.5 18.5 17 46.5 15.2 8 28.2 1.5 40.7 41.7 ASD430F-02-10ST 19.7 21 49.3 18.5 10 31 ASD530F-02-06ST 17 12.8 48.3 6 25.2 20.3 ASD530F-02-08ST 18.5 15.2 51.3 8 28.2 R 1/4 49.3 15.4 9.5 23 19.8 19 55.3 1.5 53.7 ASD530F-02-10ST 21 18.5 54.1 10 32.6 23.1 ASD530F-02-12ST 22 20.9 55.9 12 34.4 ASD530F-03-06ST 17 12.8 48.3 6 25.2 20.3 ASD530F-03-08ST 18.5 15.2 51.3

Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet 8 N S U F GN GS HS 04 06 08 UM 02 10.8 7 2 1.4 KQ2H02-M5N 3 6 10 15 20 J JB K 04 14.7 8 4 2.5 KQ2H04-M5N ZP3 Y 8 02 10.8 7 2 1.4 KQ2H02-M5N 04 14.7 8 4 2.5 KQ2H04-M5N 06 10 6 KQ2H06-M5N 10 13 16 Vacuum inlet: One-touch fitting Applicable tubing O.D.

1/4, 3/8 [1(P), 5(R1), 3(R2) port] VQC 66 ( ): VQZ315-G1-02 VQZ L-type plug connector (L): VQZ3 5 (R)-L10 1 02 03 1 8 9 DIN terminal (Y): VQZ3 5 (R)-Y10 1 02 03 1 8 9 SQ 105 [107.2] Approx. 300 (Lead wire length) VFS VFR 57 [64] VQ7 112.9 Max. 10 73 Pg7 Applicable cable O.D. 3.5 to 7 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: AC M-type plug connector (M): VQZ3

Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 M5 x 0.8 AS221F-01 AS231F-01 R 1/8 AS221F-02 AS231F-02 R 1/4 AS321F-02 AS331F-02 R 1/4 AS321F-03 AS331F-03 R 3/8 AS421F-04 AS431F-04 R 1/2 AS121F-U10/32 AS131F-U10/32 10-32 UNF AS221F-N01 AS231F-N01 NPT 1/8 AS221F-N02 AS231F-N02 NPT 1/4 AS321F-N02 AS331F-N02

AS2301F-02, AS2311F-02 AS2201F-02, AS2211F-02 AS3201F, AS3211F AS4301F, AS4311F AS4201F, AS4211F AS3301F, AS3311F Supply pressure: 0.5MPa Supply pressure: 0.5MPa Supply pressure: 0.5MPa 16 25 6 400 1000 14 10, 12 1500 12 80, 10 20 12 Effective area (mm2) Effective area (mm2) 08 06 Effective area (mm2) 300 10 Flow (l/min(ANR)) Flow (l/min(ANR)) Flow (l/min(ANR)) 06 10 1000 4 15 500 8 04 200

plunger VM220-02-05 VM230-02-05 Polyacetal roller Hard steel roller Roller plunger VM220-02-06 VM220-02-06S VM230-02-06 VM230-02-06S Cross roller plunger VM220-02-07 VM220-02-07S VM230-02-07 VM230-02-07S Polyacetal roller Hard steel roller Toggle lever VM220-02-08 VM230-02-08 VM230-02-30R VM230-02-30B VM230-02-30G VM230-02-30Y VM220-02-30R VM-30AR Red Push button (Mushroom) VM-30AB Black

EDS file URL http://www.smcworld.com Model number EDS file Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 ex260_sen1_24_v.eds 1 EX260-SEN1 ex260_sen2_24_v**.eds 2 EX260-SEN2 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 OFF [F99] Reset to default settings [F80] Power saving mode OFF Perform the setting with the 3 step setting mode, simple setting mode and function selection mode.

Selection of connected sensor [ 10] 10 L/min (PFM510) [F 0] [Un i] Unit selection function [ L] L/min The zero clear function has been performed while the fluid is flowing. "Er4" will be displayed for 1 second. Perform the zero clear function again under no flow conditions. Attaching the connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.

L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-1, gal(US)/min, gal(US) SET SET Reverse output SET Non-Reverse output Reverse output ( ) ON 90 Colour Pin number Content 50 ms OFF No Set value input Set value ( ) Input of the Set value for the upper 3 digits (OUT1) 4 Input of the Set point 2 (OUT1) 1 DC(+) Brown SET Time SET Do not operate in an atmosphere containing flammable, explosive or corrosive

Doc.IZ*-OMU0031 / Series IZE11 2 7 8 10 10 11 14 15 18 18 F0 19 F1 OUT1 20 F2 OUT2 22 F3 22 F4 23 F5 24 F6 25 F98 26 F99 27 28 31 32 32 34 -1No.IZ*-OMU0031 1) (ISO/IEC)(JIS) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment

800/40 1600/80 1600/80 2400/130 XL-80 XL-100 XL-160 AC90240V Ass'y XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 Ass'y 1 2 3 H4 AC100V 600/150 800/220 1200/350 / AC200V 2400/150 3200/220 4800/350 Ass'y XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 Ass'y 2 3 4 H5 AC100V 800/180 1200/300 1600/400 / AC200V 3200/180 4800/300 6400/400 1)/ 2)16 PTC() 200V 200 PTC 150 100V PTC Ass'y 0 5 10

-24S T c V 5-6 4. 12/12 FGX-OM-L009-B Revision history A (Sv) 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2013 SMC Corporation All Rights Reserved

Maintenance 8 1-1) Element replacement 8 1-2) How to replace element 8 2-1) Replacement of seals 10 2-2) How to replace holder assembly 10 3 / 13 FGX-OM-N027-B Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

For detailed description of the signals, refer to the following pages. 15 (2) Internal circuit (Numbers in brackets indicates the pin numbers) (5) PWR_DC24V LF (6) PWR_GND Output signal GND (9) CTR (10) CYL (11) VAL (16) RF (17) PWR Max.

No.D-S-OMZ0004 PRODUCT NAME Solid State Auto Switch MODEL / Series / Product Number D-M7BA# Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 8 Names 8 Definition and terminology 9 Mounting and Installation 10 Installation 10 Troubleshooting 12 Specifications 15 Dimensions 16 -1No.D-S-OMZ0004 Safety Instructions These safety instructions are intended