OFF No.3 No.4 No.5 No.6 -73No.PS-OMV0003CN-G No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -74No.PS-OMV0003CN-G No.
Withstand pressure 600 kPa Detection nozzle 1.5 *3 Consumption flow rate 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 25 mA or less Switch output 1 output (NPN or PNP) Maximum load current 10 mA Maximum applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short
When washing the micromesh element, do not wipe it using a stiff brush or rag. 0.03 12 08 20 24 10 16 Pressure drop (MPa) 06 0.01 0.005 COM. N.O.
The Wireless Remote is 10 already registered. 3. When another Wireless Base is in pairing 3. Another Wireless Base is mode, the Wireless Remote will be displayed for the Base. Keep one Wireless Base in pairing mode. in pairing mode. -122No.EX-OMV0017-C 10. Release Notes Revision No.
The wireless slave is 10 already registered. 3. When another wireless master is in pairing 3. Another wireless master is mode, the wireless slave will be displayed for the master. Keep one wireless master in pairing mode. in pairing mode. -121No.EX-OMV0017-B 10. Release Notes Revision No.
The wireless slave is 10 already registered. 3. When another wireless master is in pairing 3. Another wireless master is mode, the wireless slave will be displayed for the master. Keep one wireless master in pairing mode. in pairing mode. -121No.EX-OMV0017-A 10. Release Notes Revision No.
-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 8 10 10 12 12 12 16 16 1 1.5 1 1.25 1.5 1.75 1.5 2 D-X Technical Data 1139 JC Series Dimensions of Accessories Rod end nut (mm) d: Thread nominal size Model Order number M8 x 1 M8 x 1.25 M10 x 1 M10 x 1.25 M10 x 1.5 M12 x 1.25 M12 x 1.5 M12 x 1.75 M14 x 1.5 M16 x 1.5 M16 x 2 M18 x 1.5 H 5 5 6 6 6 7 7 7 8 10 10 11
Do not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. Caution Pilot port piping 12(P1) and 10(P2) piping should be as follows according to the model. 2. Do not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only.
When washing the element, do not wipe it using a stiff brush or rag. -20 -24 10 Pressure drop (kPa) -28/32 -06 -10 -12 -08 -16 -04 10 100 1000 1 Flow rate (L/min) Conditions Fluid: Turbine oil Class 2 VG56 Viscosity: 45 mm2/s Filter material: Micromesh Nominal filtration: 74 m Differential Pressure Indication Differential pressure indication switch Operating pressure24 kPa Mounting orientation
Max. 10 VZ VS VFN Mounting bracket (A port) P = 26 L Dimension n: Stations n L L1 L2 Formula L1 = 26 x n + 36 L2 = 26 x n + 10 2 88 62 3 114 88 4 140 114 5 166 140 6 192 166 7 218 192 8 244 218 9 270 244 10 296 270 [ ]: With light/surge voltage suppressor 4-7-7 8 Series VT307 Dimensions: Individual Exhaust (Interchangeable with VT301 for mounting) VV307-01-3--F P = 26 (Applicable cable O.D
Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 P362030-201 Bracket P36201023 P36202028 Pressure gauge2 G33-4-01 G43-4-01 G33-2-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-4-01 G43-10-01 1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached two
10 M6 X 1.0 M6 X 1.0 M8 X 1.25 M8 X 1.25 M10 X 1.5 M10 X 1.5 45 52.5 59 64 76.5 86 33.5 38.5 45 50 62 71.5 47 51 58 58 72 72 21 27 27.5 28.5 37 37 13 14 15.5 16.5 19 19 13 13 14 14 20 20 30 35 40 45 45 55 9 12 13 13 16 16 12 16 20 20 25 30 32.5 38 46.5 56.5 72 89 46 52 65 75 95 114 10 14 18 18 22 26 22 30 35 35 40 40 Wl Stroke range (mm) Bore size (mm) ZZ S ZZ WL W V S RF P NB N MO 32 40
(mm) Operating pressure range (MPa) Actuation speed (mm/s) MQML Standard type 6(Standard only) 10 16 20 25 6: 0.02 to 0.7 10 to 25: 0.005 to 0.7 0.5 to 1000 5 to 3000 MQMLH High speed/frequency 0.01 to 0.7 NEW NEW Low Friction Cylinder (Single Acting) Series MQP Bore size (mm) 4 6 10 16 20 Operating pressure range (MPa) Thrust control standard (N) Series 0.01 to 8 0.03 to 19 0.08 to 50 0.20
D -DIN connector DL -DIN connector with light DO-For DIN connector (without connector) Orifice and port size combinations T -With conduit terminal TL-With conduit terminal/light Class Orifice diameter Port size 2 3 4 5 7 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) Connector 1/4 (8A) 3/8 (10A) 4 All class B coils are equipped with surge voltage suppressor.
Compact size (Width: 15 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing.
(Adjustable) 1 to 10% of set prss. (Variable) 3% F .S. or less (Fixed) 1 to 10% of set prss.
Do not introduce air from the outlet side as this can damage the damper. 0.06 0.06 P1 = 0.1 MPa 0.04 0.04 Caution 1. Use a check valve (AKM series) to prevent back flow of the lubricant when redirecting the air flow before the lubricator. 0.02 0.02 0 0 15000 10 5000 0 2000 4000 6000 0 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Maintenance AL40 Rc 1/2 Warning 1.
10 20 20 20 20 5 5 10 0 0 0 0 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 2 4 6 8 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0 2 4 6 8 10 12 14 16 Suction flow rate [L/min(ANR)] Suction flow rate [L/min(ANR)] Supply pressure [MPa] Supply pressure [MPa] ZU07SA Exhaust Characteristics Exhaust Characteristics Flow Rate Characteristics Flow Rate Characteristics ZU07LA 100 80 100 50 60 50 Vacuum pressure Vacuum
x 10-10 for the standard material (FKM) at ambient temperature, excluding gas permeation Leakage Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperature, excluding gas permeation Flange type KF(NW) KF(NW),K(DN) Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material) Note 2 Surface treatment for body Outside: hard