SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S31-04-M3"

The intersection H is the amount of moisture included in the compressed air 35 ft3 (1 m3) at 102psi (0.7 MPa), and a pressure dew point 77F (25C). The amount of moisture is 0.003 oz./ft3 (3.0 g/m3). 10.

Note 1) Sampling air flow rate: Number of particles contained in 75l of air Note 2) Actuator: 1 million cycles Solenoid valve: 2 million cycles Particle generation characteristics of CM2 Particle generation characteristics of CXSL Particle generation characteristics of CY1B 106 106 106 Particle concentration (particles/m3) Particle concentration (particles/m3) Particle concentration (particles

Applicable shaft types: S, W, Y X = Q1 = M L1 = L2 = L1 Q2 = M Q1 [mm] [mm] Size Thread 30 50 63 80 100 M3 x 0.5 2.5 M5 x 0.8 4 4 M6 x 1 5 5 M8 x 1.25 6.8 6.8 6.8 M10 x 1.5 8.5 8.5 M12 x 1.75 10.3 10.3 Rc1/8 8 8 Rc1/4 11 Size Thread 30 50 63 80 100 M3 x 0.5 2.5 M5 x 0.8 4 4 M6 x 1 5 5 M8 x 1.25 6.8 6.8 6.8 M10 x 1.5 8.5 8.5 M12 x 1.75 10.3 10.3 Rc1/8 8 8 Rc1/4 11 [

It is calculated using the following formula: 1 x 105 Kv = Q (8) P 1000 Kv : Flow coefficient [m3/h] Q : Flow rate [m3/h] P : Pressure difference [Pa] : Density of fluid [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow rate characteristics are shown in Graph (2).

Mount the sensor head using two M3 screws (not supplied with the product). M3 screws M3 screws M3 screws Due to the construction of the sensor, the sensor head housing is shared with GND. Install and supply power with great caution to avoid short-circuit with the +24 V power supply. The detection port is opened to detect static electricity.

To secure the emitter cartridge with a screw, use an M3 x 0.5 12mm cross recessed round head screw (The screw needs to be prepared by the user). M3 screw recommended tightening torque is 0.25 to 0.35 Nm. Install the ionizer so that the emitter cartridge can be removed for maintenance and replacement of the emitters.

Max. load mass Review M1, M2, M3. M max is the allowable moment. 2 = M/M max 2. Static moment Review Me1, Me3. Me max is the allowable moment. 3 = Me/Me max 3.

. : MH-G04 (30g) 664 Series MHY2 180 Angular Style Air Gripper Cam Style Dimensions MHY2-10D Pin hole positioning 30 9 9 2 x M3 x 0.5 thread depth 4 4 (Thread for mounting attachment) 4 x M3 x 0.5 through (Mounting thread) 3H9+ 0.025 0 depth 3 6 0.005 0.025 4 4 x M3 x 0.5 thread depth 6 3 6 (Mounting thread) 2 x 3.4 through 2 x M3 x 0.5 depth 6 12 (Mounting hole) (Mounting thread) (Limted

(mm) IZN1007 (inch) 3.5 2 x M3 x 0.5 depth 10 26 32 7 25.8 Note 1) 11 Note 1) Dimensions of the resin part stated in Provide Grounding on page 454.

8 5 Width across flats 12 10.6 17 Nozzle Type Ionizer IZN10E Series Dimensions L-bracket IZN10-B1 17 (Mounting angle adjustable range) 40 2 x M3 7.5 2 x 3.4 2 x R10 25 5 40 50 Internal mounting 2 x 3.4 20.5 33 30 30 52 46 44 26 17 11 26 12 8 x 3.4 2 x Hexagon socket head cap screw M3 x 6 (Accessory) 40 5 22.7 Internal mounting Pivot mounting 21 33 30 (Mounting angle adjustable range) (83)

(M3, M5 type only) Use SMCs recommended grease. Grease pack part number: GR-S-010 (10 g) M3, M5, Rc port, NPT port Use the correct tightening torques listed below.

Max. load mass Review M1, M2, M3. M max is the allowable moment. 2 = M/M max MY 2. Static moment CY 3 = Me/Me max Review Me1, Me3. Me max is the allowable moment. 3.

x 0.5 M6 x 1 M3 x 0.5 M10 x 1 M4 x 0.7 M10 x 1 M4 x 0.7 M20 x 1.5 M5 x 0.8 M26 x 1.5 M6 x 1 M26 x 1.5 M6 x 1 M32 x 2 0.007 0.037 M8 x 1.25 M8 x 1.25 M8 x 1.25 M10 x 1.5 P (Piping port) W X Y ZZ Model Mounting Nut/Included in the package (2 pcs).

x 0.5 6 M3 x 0.5 5.5 2.6 2H9 3 1.5 M3 x 0.5 6 112211221122MHZ2-16D 17.4H9 10.8 19 M3 x 0.5 29.5 6.5 M4 x 0.7 4.5 M4 x 0.7 8 3.4 3H9 3 1.5 M4 x 0.7 8 MHZ2-20D 22.4H9 12 23 M4 x 0.7 39.8 8.3 M5 x 0.8 8 M5 x 0.8 10 4.3 4H9 4 2 M5 x 0.8 10 MHZ2-25D 13 37 49.7 10.8 M6 x 1 10 M6 x 1 12 5.1 4H9 4 27.4H9 3 M6 x 1 12 M5 x 0.8 AM AL AN AP AQ AR AS AT AU AV AW AX AY AZ Model 1122112211221122+2.2 0

Y g: Gravitational acceleration, a: Average speed 24 Series MY1W Maximum Allowable Moment/Maximum Load Weight Maximum allowable moment Maximum load weight (kg) m1 Maximum allowable moment (Nm) M1 Bore size (mm) Model M2 M3 m2 m3 Select the moment from within the range of operating limits shown in the graphs.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (kg) m M3 m max Model CYV15 1 CYV32 5 (Nm) M1 M2 Model CYV15 CYV32 M1 0.3 3 M2 0.6 4 M3 0.3 3 m m Static Moment Moment generated by the workpiece weight even when the cylinder is stopped Pitch moment M1 = m x g x (L + B) x 103 Yaw moment M3 = m x g

Hard anodized Chromated Countersunk head screw Nut Rod seal Piston seal Gasket Plug Nickel plating Nickel plating Zinc chromated D-X 23 MXH Series Dimensions: 6 LT 9 15 LA LB 8 J x M3 x 0.5 Depth 5 3 x M4 x 0.7 through Pilot hole dia 3.3 2 x 3 x 6 counterbore depth 3.3 2 x 2 x M5 x 0.8 Cylinder port (With plug for port) 4 x M3 x 0.5 Depth 5.5 2 x M5 x 0.8 Cylinder port 4 x M3 x 0.5 Depth

x 0.5 Depth 6.5 LA LB 8 MXS MXQ Guide rail width 5 3 x M4 x 0.7 through Bottom hole dia 3.3 6 x 6 counterbore depth 3.3 4 x M3 x 0.5 Depth 5.5 Plug for port (Hexagon socket head set screw) 4 x M5 x 0.8 x 4 l 2 x M5 x 0.8 6.5 5 MXF 4 x M3 x 0.5 Depth 4.8 MXW 17 38 39 MXJ 19 10 18 19 18 15 MXP 5 5.5 10 5.5 5.5 MXY NS 4 9 10.5 8.5 31 + Stroke MTS 39.5 + Stroke 16 4 x M3 x 0.5 Depth 4.8 10 5

Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping. The switch can be installed horizontally depending on the installation location. Mounting screw M3 x 5L Mounting screw M3 x 5L The tightening torque for bracket mounting screw should be 0.5 to 0.7 Nm.