Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.
How to Order SY100 68 A Lead wire length Nil 300 mm 6 600 mm 10 15 20 25 30 50 1000 mm Caution 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Failure to meet IP65 performance may result if using alternative connectors than those shown above, or when insufficiently tightened.
If equipped with a light, be careful not to damage the light with the cords lead wires. 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For DC 10-SY3120-5LO-M5 SY100-30-4A-20 For AC 10-SY3120-1LO-M5 SY100-30-1A-20 Precautions Plug in and pull out the connector vertically without tilting to one side.
How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover Groove For other voltages of AC: SY100 30 3A DC polar indication Lever Pin Without lead wire: SY100 30 A -+ Socket Lead wire length Nil 6 10 15 20 25 30 50 (with connector and 2 of sockets only) 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lead wire
---I -~ _:_::-::: : ::-0.7ipa ~,,:-~~.'. "". 0~~1~00 ~~2~0~~~ ~ 0 30~0-4~OLO-~50~0~~60~0 0 1500 3000 4500 6000 7500 Air flow rate Qlmin (ANR) Air flow rate Qlmin (ANR) AMH350 AMH850 0.5MPa )7MPa I I // ",0.06I-Air pressure 0.3MPa '" 0.06 Inlel air pressure 0.3MPa / a. V o/pa ~pa ::;; a. V~V ::;; Q) /-Y :; ~0 . 04 '// ~ / /,/ ~ 0.04
0 500 1000 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) AR40-A Rc1/2 AR40-06-A Rc3/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 1000 2000 3000 4000 0 0 1000 2000 3000 Flow rate L/min (ANR) Flow rate L/min (ANR) 452 Regulator AR10-A to AR40-A Series Pressure Characteristics (Representative values) Conditions: Inlet pressure 0.7 MPa,
200 400 600 800 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AR30(K)-B Rc3/8 AR40(K)-B Rc1/2 AR40(K)-06-B Rc3/4 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure [MPa] 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 00 0 0 1000 2000 3000 4000 5000 0 1000 2000 3000 500 1000 1500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)]
AS3201F, AS3211F AS3301F, AS3311F AS4201F, AS4211F AS4301F, AS4311F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13, 16 10, 11, 12 1500 1000 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable
DC (+) Blue DC () OUT DC 4-wire type Brown Black DC (+) Blue Orange DC () Connector Specifications M8-3 pin Connector model M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 1 2 Pin arrangement 3 4 4 3 3 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Conformed standard 300 m/s2 Impact resistance IP67 (IEC60529 standard) Enclosure 100 M or more at 500 VDC measured via megohmmeter Insulation resistance 1500
Furthermore, the maximum response speed of the sensor for the stroke reading cylinder is at a maximum cylinder speed of 1500 mm/s (15 kcps). Input/Output The input/output of the stroke reading cylinder is performed by a 7 shielded twisted pair wire from the sensor section plus a connector.
metal parts Available with two types of seal material (NBR or FKM) to suit application is standard Special scraper to prevent liquid from entering cylinder Uses grease that meets FDA standards Series CG5 How to Order Auto Switch Standard With Auto Switch (Magnetic Piston) Option X6011 CG NFPA Nil D Mounting X D E C F G L S P Stroke (mm) Bore 40 50 63 80 100 Max Stroke 800 1200 1200 1400 1500
Standard Strokes Bore size (mm) Standard strokes (mm) 40 50 63 80 100 125 160 25 to 1000 Accessories (Options) 25 to 1000 25 to 1000 25 to 1300 Bracket pin, Knuckle bracket, Knuckle pin, Knuckle, Y-type knuckle, Rod end nut 25 to 1500 50 to 1300 Refer to pages 408 and 409 for part numbers and dimensions. 50 to 1500 Note) Refer to pages 232 and 233 to determine stroke limitation depending
1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.08 MPa Ambient and fluid temperatures Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Lubricant Not required (Non-lube) MWB-UT CP96N C96N Lock Unit Accessories Auto Switch Made to Order Piston speed 50 to 1000 mm/s*1 Stroke length tolerance Up to 500 st: +2.0 0 , 501 to 1000 st: +2.4 0 , 1001 to 1500
Auto Switches Common Specifications Solid state auto switch Type Reed auto switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less Leakage current None Operating time 1 ms or less 1.2 ms Impact resistance 1000 m/s2 300 m/s2 50 M or more at 500 VDC Mega (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire
1 b How to Order Silencer Assembly (With sound absorbing material) (For ZL6) How to Order Lead Wire with Connector Assembly for Supply Valve/Release Valve (For ZL3/ZL6) ZL6 SC1 A SY100 30 4 A 6 Lead wire assembly with connector for supply valve and release valve Silencer assembly (With sound absorbing material) q Rated voltage 24 VDC q Lead wire length Nil 300 mm 6 600 mm 10 1000 mm 15 1500
(Red) (Black) Single solenoid SJ3000-46-S-l Double solenoid, 3 position type, 4 position type SJ3000-46-D-l (White) (Red) (Black) N C C N Lead wire length For single solenoid : SJ3000-46-SC-l (Red) (Black) Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm (White) (Red) For double solenoid For 3 position type : SJ3000-46-DC-l For 4 position type (Black)
PEND Specifications Water/Non-corrosive liquid Fluid 0.1 to 0.6 MPa Operating pressure Water resistance 1.2 MPa 5 to 60C (No freezing) Operating temperature range Operation Diaphragm style 100 M (500 DC by megameter) Insulation resistance Withstand voltage 1500 VAC for one min.
1 Air Tank Series AT Model/Standard Specifications AT11C AT22C AT37C AT55C AT75C AT125C AT150C (1) AT220C (1) AT6C Model Fluid Tank capacity (l) 400 500 700 Compressed air 1000 1500 2000 3000 100 200 Max. operating pressure (MPa) Port size 0.97 Rc 1/2 Rc 3/4 Rc 11/2 2B flange 3B flange 4B flange Set pressure for safety valve (MPa) 0.97 1.46 0 to 100 Proof pressure (Under water pressure) (
Cushioning nearly equal to a shock absorber is achieved with a unique cushion ring configuration and cushion seal design. 3.5 80 25 to 1300 25 to 1000 25 to 1500 100 50 to 1000 50 to 1300 125 50 to 1200 50 to 1500 160 CHAW CHA Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
If 0.6 MPa air is constantly consumed at 1500 L/min (ANR) on the outlet side, the booster regulator will run continuously with almost no stopping time, resulting in a reduced service life.