Search Results "ISE70-F02-L2-A"

Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.

Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.

Description Material AS800 AS900 6 7 8 O-ring O-ring Spring NBR NBR Stainless steel KA00069 KA00460 14115 KA00072 KA00462 14124 ASN AQ ASV Dimensions: AS420/500/600 Dimensions: AS800/900 AK VCHC ASR ASQ 2 x Port size 2 x Port size L3 L2 L1 D Dimensions L1 L2 D Min. L3 (1) Model Port size Max.

Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE75G (0 to 2 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])

Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: Rc, Port Size: 06 (3/4), Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)

Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)

Output Specification: L2 (IO-Link/Switch output 1 + Switch output 2), Units specification: w/Units Selection Function, Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: A (Bracket)

Rated Flow Range: 20 to 2000 L/min, Thread Type: Rc, Port Size: 3/4, Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: Yes

Rated Flow Range: 5 to 500 L/min, Thread Type: NPT, Port Size: 1/2, Output Specifications: L2 [Out: IO-Link, Switch Output (N/P); Func: Switch Output (N/P); Monitor Unit Model: None], Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: Yes

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

It is again necessary to connect a contact protection box in order to extend its life. Please contact SMC in this case. If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box.

For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.

2 A 2 A 24 VDC 0.63 A 1 A 1 A Temperature rise*5 25C 25C 25C 1 Leakage: The value at a differential pressure of 0.01 MPa or higher and an ambient temperature of 20C 2 This product has an IP67 enclosure, but if water enters the product, it may result in malfunction or breakage.

For a facility having a small installation area (that cannot vent the air naturally): Make a forced air exhaust vent in a wall at a high level and an air inlet in a wall at a low level.

Be certain to adopt a reliable connecting method if the rotary table is used very frequently or if it is used in a location that is exposed to a large amount of vibrations. 5. There may be cases in which a speed reduction circuit or a shock absorber is required.

For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.

Extention cable A dimension M L Z I/O cable Note 1) 1000 Note 2) 15.5 (500) 5 5 2 x M5 depth 8 44 3000 60 42 60 (A) 5000 2 x for M4 thread Note 2) Note 1) For the 3-point stoppable type, the I/O cable is a 9-core type and for the 5-point stoppable type, a 11-core type is used.