A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.42198 lb
The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 1A, IT1000 OTHER SPT VERSION, 1.16600 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 1A, IT1000 OTHER SPT VERSION, .66000 lb
Please contact us for the latest version.sales@ocaire.com, E/P REGULATOR, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, AA, IT1000 M5 PT VERSION, .50380 lb
Please contact us for the latest version.sales@ocaire.com, E/P REGULATOR, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, AA, IT1000 M5 PT VERSION, .50380 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR 1/4 PF, EUROPEAN, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, D7, IT2000 1/4 INCEUROPEAN, 1.87392 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR W/GAUGE, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, .88184 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR 1/4 PT, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, 1.60448 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, 1.75796 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, DB, IT4000 1/4 INCNPT VERSION, 1.44760 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 1.45200 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 2.33384 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.50920 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.45200 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, DB, IT4000 1/4 INCNPT VERSION, 1.48720 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance. REGULATOR, E/P, HIGH PRESSURE. High Press. E/P Regulator. 700.00000 lb. N11.
The test was performed in the axial and right angle directions of the main valve and armature for both energized an de-energized conditions. 1 (P) 5 (R1) 3 (R2) 3-position exhaust center (A) 4 (B) 2 Specific Product Precautions 1 (P) 5 (R1) 3 (R2) 3-position pressure center (A) 4 (B) 2 Caution Internal Wiring Specifications 1 (P) 5 (R1) 3 (R2) M8 Connector: Wiring specifications (EVS1-02)
VQZ300 Port size Symbol VQZ200 VZ 1 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 M5 thread Rc (PT)1/4 C4 C6 C8 C10 M5 02 Metal seal Rubber seal 1 (P) 3 (R) VT (A) 2 N.O. 2 VT 1 (P) 3 (R) Note 1) Refer to p.2.10-18 for inch size Onetouch fittings. VP (A) 2 N.C. 3 VG 1 (P) 3 (R) Manual override (A) 2 N.O.
5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil R Metal seal Double FJG Rubber seal 1 (P) 5 (R1) 3 (R2) Rated coil voltage (A) 4 (B) 2 Option 3 4 24VDC FIG 12VDC Nil None 1 (P) 5 (R1) 3 (R2) Voltage other than above (50VDC or less) Indicator light with surge voltage suppressor 9 Z A02 VS1 01
With 1 shock absorber (Set on the driving cylinder side when packed.) 25 B 32 BS 40 Standard stroke Long stroke * Refer to p.3.8-10 for minimum strokes for auto switch equipped style. Applicable auto switches/Refer to p.5.3-2 for further information on auto switch.