Rated Pressure Range: 1 to -101 kPa, Piping: URJ1/4, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: TSJ1/4, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: TSJ1/4, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: Rc1/8, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: G1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -100 to 100 kPa, Piping: URJ1/4, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Pressure Switch RoHS ZSE20(F)/ISE20 Series IP40 How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range w Output specification e Unit specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description Nil Units selection function*1 M SI unit only*2 P Units selection function
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C4H (ø4 One-touch Fitting, Straight Type), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, PRESSURE SWITCH, ISE1-6, N59, 22 lb
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: C6H (ø6 One-touch Fitting, Straight Type), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 22.00000 lb
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 22 lb
The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Simple connection/disconnection, High retaining force, Miniature size, Accepts many styles of plastic tubing, GASKET M5 FITTING, CONNECTORS, M MINI FITTING, 21, M NO SIZE RATING, .00002 lb