This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH W PIPING ADAPT, INSTRUMENTATION, IS/NIS PRESSURE SW FOR FRL, DB, NIS1000E/M 1/4 NPT, .20943 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH W PIPING ADAPT, INSTRUMENTATION, IS/NIS PRESSURE SW FOR FRL, EB, NIS1000E/M 3/8 NPT, .13668 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH W PIPING ADAPT, INSTRUMENTATION, IS/NIS PRESSURE SW FOR FRL, FB, NIS1000E/M 1/2 NPT, .13668 lb
Style: Pressure Switch, Body Size: 40 (AC40), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa, Body Type: Standard
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Style: Pressure Switch, Body Size: AC40, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa, Body Type: Standard
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Rubber cushion, Operating Pressure(MPa
: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Body Size: 610 (AC50, AC60-D), Thread Type: N (NPT), Port Size: 04 (1/2), Body Type: 1 (Slim)
Body Size: 44 (AC40-D), Thread Type: N (NPT), Port Size: 04 (1/2), Body Type: 1 (Front and Back Port Selectable)