CV Standard Stroke MVGQ Bore size (mm) Standard stroke CC 10 15, 30, 45, 60 16 15, 30, 45, 60 RB Made to Order Specifications (For details, refer to page 10-21-1.)
exhaust center: VQ440 -l 3-position pressure center: VQ450 -l 3-position double check: VQ460 -l 0 1 0 1 0 1 0 1 0 1 179 106 90 73 50 2 11(12.5) 4(A) port 11(12.5) 2(B) port Indicator light Indicator light 165 179 106 90 2 59 73 50 2 4 48 38 24.6 11(12.5) 2(B) port 11(12.5) 4(A) port B A 14 12 1 5 3 4 2 45 30 38 24.6 A B Manual override 2 x 5.6 Mounting hole 48 B A 14 12 5 3 1 45 30 2 x 5.6
Refer to manifold ordering. 24 23 22 21 20 19 18 17 Terminal no. 28AWG 16 15 6 14 13 Red 12 11 10 9 8 7 26 2 25 1 30 (20P) 37.5 (26P) Connector terminal number 6 5 4 3 2 1 Triangle mark indicator position <26P> <20P> (15.6) Terminal no. Terminal no.
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+
30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+) Brown LED Indicator light D-A90 without indicator light (+) M2.5 x 4l Slotted set screw Resistor Load Reed switch DC power supply Reverse current prevention diode OUT Black () DC () Blue Most sensitive position Note 1) Operating load is an induction load.
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+
The time between two restarts of the outputs is too short the time interval must be at least 30 seconds. 0x01F5 None 501dez The process image for parameter values must contain valid values. The SI unit needs a HW reset when the process image contains new parameter values.
PSE202A-(M)# IO-Link/NPN open collector 1 output + NPN open collector 4 output specification When used as an IO-Link device Max. 30 V, 80 mA Residual voltage 1.5 V or less When used as a switch output device Max. 80 mA Residual voltage 1.5 V or less -18No.PS-OMW0012-C PSE203A-(M)# IO-Link/PNP open collector 1 output + PNP open collector 4 output specification Used as IO-Link device Max. 30
Do not use a cable longer than 30 m. Consult with SMC for the use with a cable longer than 30 m. Connect the 0 VDC wire (blue line) directly or as close as possible to the 0 VDC terminal of the DC power supply.
Setting of reversed output 1_P/1_N (page 29) * Input of set values Setting of Add/dEC P1AH/n2AH Setting of P1L/n1LP1H/ n1H/H1 (Page 30) Setting of P_1/n_1/H_1 (Page 30) P1dH/n1dH (Page 31) 4 Select display color SoG/ SoR/ Red/ GRN (page 33) 5.
Request message to write (from master) 02 31 30 57 53 56 31 30 30 32 30 30 03 51 Numerical data Address BCC data End code Request to write Identification code Start code Response message from the product 02 31 30 06 03 06 Address End code BCC data Affirmation code Start code Code Symbol/Data ASCII code Start code STX 02H Address 10 31H 30H Required content W (write) 57H Identifier SV1
Request message to write (from master) 02 31 30 57 53 56 31 30 30 32 30 30 03 51 Address BCC data End code Start code Request to write Numerical data Identification code Response message from the product 02 31 30 06 03 06 Affirmation code Start code Address End code BCC data Code Symbol/Data ASCII code Start code STX 02H Address 10 31H 30H Required content W (write) 57H Identifier SV1
water 35oC 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-11 Cooling capacity (HED007) 2) Heating capacity 3200 2800 2400 Heating capacity W Facility water 35oC 2000 1600 Facility water 10oC 1200 Facility water 25oC 800 400 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-12 Heating capacity (HED007) 9.5 Performance Chart 9-16 A_HEC-OM-K001-1.7 Chapter
Table5 Allowable load N Size Load direction Fsa Fsa Fsb Fr Fr 10 15.7 7.8 14.7 15 19.6 9.8 19.6 20 49 29.4 49 30 98 49 78 40 108 59 98 Fsb Point of application of force of Fr is the center of shaft flat face and longer dimension of the key.
to 180 24 to 750 16 to 500 8 to 250 30 to 1140 20 to 760 10 to 350 range 801 to 900 24 to 610 16 to 410 8 to 200 30 to 930 20 to 620 10 to 280 Actuator specification 901 to 1000 24 to 500 16 to 340 8 to 170 30 to 780 20 to 520 10 to 250 1001 to 1100 30 to 660 20 to 440 10 to 220 1101 to 1200 30 to 570 20 to 380 10 to 190 10 Max acceleration/deceleration [mm/s2] 5000 Positioning repeatability
Recommended tightening torque for the port Unit: N m Thread size 1/8 1/4 3/8 1/2 3/4 1 Torque 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 Recommended tightening torque for the pressure gauge port Unit: N m Thread size 1/8 Torque 3 to 5 *Please refer to "10-7.
Do not use a cable longer than 30 m. Consult with SMC for use with a cable longer than 30 m. Connect the 0 V DC wire (blue line) directly or as close as possible to the 0 V DC terminal of the DC power supply. -7No.PS-OMH0003-F Environment Avoid exposure of this product to direct sunlight. If using in a location directly exposed to sunlight, shade the Pressure switch from the sunlight.
23 30 146 182 30 25 37 167 199 25 28.5 37 167 202 20 33 44 210 227 Without Rear Plate Stroke range (mm) Long Stroke Bore size (mm) 20 25 32 40 Bore size (mm) 20 25 32 40 R Z Y 250 to 400 14 190 129 350 to 500 207 14 146 350 to 600 14 210 146 350 to 800 15 236 191 Note) Dimensions marked with are not required for the one without rear plate. 9-4-8 9 Fine Lock Cylinder with Guide Series MLGC
28 70 119 50 42 56 70 29 30 108 75 128 11-/22-MXP16-30 104 Precision air slide table MXP/MXPJ6 1122Made to Order Specific Product Precautions Anti-corrosive specifications for guide unit -X42 Air cylinder Rotary actuator Air gripper Directional control valve Fittings & Tubing Pressure switch Clean gas filter Flow control equipment Filter, Pressure control equipment Air preparation equipment
D-A7lH, A80H D-A73C, A80C D-F7l, J79 D-F7lV, J79C D-A79W D-F9l D-F9lV D-F9lWV D-F9lW D-F9BAL D-P5DW D-A9l D-A9lV D-A7, A8 Model B 6.5 7 6 8.5 11.5 14.5 A 28.5 29 33 24 28.5 28.5 B 7 7.5 6.5 9 12 15 B 4 4.5 3.5 6 9 12 B 11 11.5 10.5 13 16 19 B 4.5 7.5 10.5 B 5 7.5 10.5 13.5 B 9 11.5 14.5 17.5 A 34.5 25.5 30 30 B 8 10.5 13.5 16.5 A 19.5 24 24 A 28 28.5 32.5 23.5 28 28 A 25.5 26 30 21