VNA VNA 2 1 2 1 2 1 VNA VNA D-X Technical Data 1177
Please contact SMC to check if the valve can be used in the application by providing the relevant fluid circuit. 223 VXS Series For Steam Dimensions/Body Material: C37, Stainless Steel Grommet Conduit terminal 34 D Q2 S2 F F Q 300 D 40 (42) 32 25 a h e Built-in full-wave rectifier type T R E (With surge voltage suppressor) C R E d g J C G1/2 f j J 2 x M depth 5 H B1 B 2 x M depth 5 H B1
A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)
For L dimension, refer to the dimensions of each kit. 12.5 (Pitch) 5.25 7.5 VQ 25 35 VKF Each manifold can be mounted on a DIN rail. Order it by indicating an option symbol for DIN rail mounting style, -D. In this case, a DIN rail which is approx. 30 mm longer than the manifold with the specified number of stations is attached. 5.5 1.25 L Dimension VQZ L = 12.5n + 10.5 35.5 1 23 No.
Refer to the manifold dimensions for the L dimension. 25 35 VQZ 5.5 To order a manifold with DIN rail already attatched, insert "D" at the end of the manifold part number. The DIN rail is approximately 30mm longer than the length of manifold. 1.25 VZ L dimension L=12.5n+10.5 35.5 1 23 No.
NPN (420 mA) E*2 PNP (15 V) *4 (2m) F*2 PNP (420 mA) + () G*2 NPN *3 W H*2 PNP *3 *2 *3 N M8 *4 ZS-33-D 2m ZS-33-F ZS-42-C PFMB7501/7102 (3.04 ) ZS-42-D PFMB7202 (3.04 ) -10No.PF-OMP0001CN-F (OUT) (IN) INOUT LCD (UP) (SET) (DOWN) LCD (OUT1)/ OUT1OUT2 ON ON/OFF (UP) (SET) ON/OFF (DOWN) -11No.PF-OMP0001CN-F F.S. () 15 V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420
Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders
A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PF2MC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.
10, 25, 40, 50, 80, 100, 125, 160, 200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.
Mount the needle seat or S valve seal assembly. 14 XL-OMP0003-A Step 6 Step 7 Tightening torque of bolt C Nm Bolt C O ring Model Tightening torque S valve seal Ass'y or Needle seat X*D-25 0.360.1 Other than X*D-25 0.630.1 Mounting surface of O ring Body Pilot port S Apply 0.3MPa of air pressure to the pilot port S.
LEFS 25 B 6N 1 20 0 1 DIN 1 6 16 25 25 I/O 32 32 40 40 1.5 m 1 1 3m 3 3m 3 5m 5 5 5m 40 16 25 32 40 16 25 32 ( ( DC24V NPN NPN A A LECP6/LECA6 6N 6N PNP PNP DC24V 6P 6P NPN NPN LECP1 1N * 1N * LECP1 PNP PNP 40 32 25 16 1P * 1P * 40 32 25 16 NPN NPN A A 10 mm 12 mm 16 mm 20mm AN * LECA6 AN * LECA6 PNP PNP B B 5 mm 6 mm 8 mm 10mm AP * AP * 100 mm 100 8m 8m 100 8 8 10m
side Nil 25 100 AC servo motor (Inclemental encoder 25 100 AC servo motor (Inclemental encoder S2 S2 100 to 120VAC LECSA1 A1 100 to 120VAC LECSA1 A1 Right side R Right side R A1,A2 A1,A2 32 200 S3 32 200 S3 200 to 230VAC LECSA2 A2 200 to 230VAC LECSA2 A2 Both side D Both side D 40 400 S4 40 400 S4 100 to 120VAC 100 to 120VAC LECSB1 LECSB1 B1 B1 25 100 S6 25 100 S6 Motor option 32 200 S7
Table 3-2 Communication Connector Connector Type (for your system) Contact signal / Analog (P1, P2 connectors) D-Sub 25-pin (male) Serial RS-485 or RS-232C (P3 connector) D-Sub 9-pin (male) Connector fitting screw (common to P1, P2, P3 connectors) M2.60.45 HRZD Series 3.3 Procedure for Installation 3-7 HRX-OM-M005 Chapter 3 Transporting and Installation Selection of the breaker for the customers
L L 1===:: . e ~l Nut ftO'a E . d Nilt ;1 ' , 0 , d d u {} B I I H B ILH ~ I Model j Bore,size(rnm} . d , I .Ji'.. ..I ~. e ~:C _ ~1IlIO
Note thatMapplies only to cup form: JT2. 3) Compatible robot manufacturer 08 8 Nil Without cup Nil NPN/With unit switching function *4 Symbol Robot manufacturer 10 10 A NPN/SI unit only *5 13 13 7) Cup material 16 16 Symbol Material 20 20 N NBR C PNP/With unit switching function *4 25 25 S Silicone rubber (White) *2 D PNP/SI unit only *5 B25 25 U Urethane rubber B30 30 F FKM 32 32 SF Silicone
Refer to the manifold dimensions drawings for the L dimension. 25 35 VQZ 5.5 To order a manifold with DIN rail already attached, insert "D" at the end of the manifold part number. The DIN rail is approximately 30mm longer than the length of manifold. 12.5 VZ L dimensions L=12.5n+10.5 35.5 1 23 No.
Port size E F G H I L M P Q A Model B J R T U C D K N O S Port 2 (A),1 (P) Port 3 (R) VEX5500 VEX5501 133.5 50 25 10 7 25 80 60 81.5 83.5 1 2, 3 4, 60 143.5 62.5 70 156.5 36.5 16.5 20 Center 2 x M6 Thread depth 9 116.5 1 2, 3 4, 1 1 25 VEX5700 VEX5701 160.5 150.5 62.5 90 60 30 15 7 173.5 37.5 100 60 13 88.5 86.5 18 2 x M6 Thread depth 6 136.5 17 82 1 4 1 4 1, 1 1 c Bracket mounting dimensions
R3/8 65.5 67.6 60.1 27.7 61.2 53.7 20.6 221 239 22 34.4 20.9 64.6 12 239 21 257 62.8 32.6 18.5 10 86.3 30 29.7 25 R1/2 65.5 71.1 63.6 27.7 62.9 55.4 24.1 239 259 22 34.4 64.6 12 20.9 Note 1) d indicates the applicable tubing O.D.
Weight g Model d T D1 H D2 D3 L1 L4 L2 L3 Min. Max.