(1) Controller setting . 25 (2) PLC set up . 25 (3) LED Display . 25 3.10 Operation test by PLC . 25 4.
RE A B D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV Bore size (mm) Auto switch model REC CX A B CY 25 32 40 91 102.5 126.5 131.5 180 206 MQQ M RHC Caution on Handling Auto Switch Mounting of Auto Switch MK(2) When mounting and securing auto switches, they should be inserted into the cylinder's switch mounting rail from the direction shown in the drawing below.
, A80, D-A7lH, A80H D-A73C, A80C 54 12 Reed switch D-A79W D-J79, J79W 53 49 11 11 12 2 wire 3 wire 56 Solid state switch D-F7 4 wire 56 14 Write "L" at the end of the part number for 3 meters of lead wire.
MDHR2-20, 30 MDHR2-10, 15 H H L L Auto switches of D-M9NV, D-M9PV and D-M9BV are used. Auto switches of D-M9N, D-M9P and D-M9B are used. Auto switches of D-M9NV, D-M9PV and D-M9BV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.
RE A B D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV Bore size (mm) Auto switch model REC CX A B CY 25 32 40 91 102.5 126.5 131.5 180 206 MQQ M RHC Caution on Handling Auto Switch Mounting of Auto Switch MK(2) When mounting and securing auto switches, they should be inserted into the cylinder's switch mounting rail from the direction shown in the drawing below.
RE A B D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV Bore size (mm) Auto switch model REC CX A B CY 25 32 40 91 102.5 126.5 131.5 180 206 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RHC Caution on Handling Auto Switch Mounting of Auto Switch MK(2) When mounting
5 7 8 7 10 13 17 22 27 14.4 19 24.8 29 38.4 49.2 17 23 29.9 33.5 38 47.5 80 210 JS20-8-125 JS32-10-125 M8 x 1.25 M10 x 1.25 43.9 49.5 1100 2500 6000 11000 JS40-14-150 JS63-18-150 M14 x 1.5 M18 x 1.5 60 74.5 11 13.5 Rod end nut (mm) d: Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10
Thread nominal size 30 Description H B C D d JS10 nut M4 x 0.7 3.2 7 8.1 6.8 JS16 nut M5 x 0.8 4 8 9.2 7.8 JS20 nut M8 x 1.25 5 13 15 12.5 D C JS32 nut M10 x 1.25 6 17 19.6 16.5 JS40 nut M14 x 1.5 8 22 25.4 21 H B JS63 nut M18 x 1.5 11 27 31.2 26 10-19-14
DC specifications of type D and DO is only available with 12 and 24 VDC.
P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D L11 L21 Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.
-MLA [ISE35-N-25-M (Switch body only)] ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] AD37 AD38 Square embedded type Note 3) GC3-10AS GC3P-010AS 0.02 to 0.2 MPa setting GC3-2AS GC3P-010AS NPN output/Wiring bottom entry ISE35-N-25-MLA ISE35-N-25-M t ISE35-R-25-MLA ISE35-R-25-M NPN output/Wiring
-MLA [ISE35-N-25-M (Switch body only)] ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] AD37 AD38 Square embedded type Note 3) GC3-10AS GC3P-010AS 0.02 to 0.2 MPa setting GC3-2AS GC3P-010AS NPN output/Wiring bottom entry ISE35-N-25-MLA ISE35-N-25-M t ISE35-R-25-MLA ISE35-R-25-M NPN output/Wiring
Conductor resistance 65/km or less, 20oC Cable 0.3mm2 x 25 cores Voltage limit AC 1000V, 1min Insulation resistance 5M/km, 20oC Note) The minimum bending inner radius of D-sub connector cable is 20mm.
Otherwise, air leakage may result. 1-6-80 Series SX3000/5000 Base Mounted Manifold Stacking Type DIN Rail Mounted Plug-in 45 Type How to Order Manifold How to Order Valve Manifold Assembly Ordering example (Type 45F/D-sub connector (25 pins) type) Type 45F (D-sub connector, 25 pins type) 45 SS5X 3 F D 05 U C4 Double solenoid (24 VDC) Single solenoid (24 VDC) SX3140-5LOZ Series SX3240-5LOZ
No.JXC-OMT0001CN-C 4 TM) (EtherNet / IP // JXC93 Series 1. . 5 2. . 7 2.1. . 7 2.2 . 8 2.3 . 9 3. . 10 3.1 . 10 3.2 . 11 3.3 . 11 3.4 . 11 3.5 . 11 1 . 11 (2) . 12 (3) . 13 3.6 . 14 1 . 14 (2). 17 (3) . 19 3.7 JOG . 20 (1) . 20 2 . 21 (3) JOG . 22 3.8 . 23 (1) . 23 (2) . 23 3 . 24 (4) . 24 3.9 EtherNet/IP . 25 (1) . 25 (2) PLC . 25 (3) LED . 25 3.10 PLC . 25 4. . 26
Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
Refer to manifold dimension drawings for L dimension. 25 35 5.5 To order a manifold with DIN rail already attached, insert D at the end of the manifold part number.
D-A5/A6, D-A59W Tie rod mounting D-G3/K3 Band mounting Solid state swich D-F5/J5, D-F5NT, D-F5W/J59W, D-F5BA, D-F5F Tie rod mounting 1.10-1 Air Cylinder/Standard Series CS1 Lube, Non-lube: 125, 140, 160, 180, 200, 250, 300 Air-hydro: 125, 140, 160 How to Order CS1 L 300 160 JR Rod boot/Cushion Rod boot Mounting J K N R H Nylon tarpaulin Heat resistant tarpaulin No cushion With cushion on
to 25 6 to 25 10/16 15/32 Bore size 610 6 D-C7/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9