Do not hold the terminal block box or the switch. ISE70 ZSE80 ISE80 Lead wire with connector ZSE ISE Knurl ZSP PS 3. Connect the colored wires coming from the cable terminal. Refer to the circuit diagram and table above to avoid mistakes.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
system Natural air cooling Operating temperature range 0C to 40C (No freezing) Operating humidity range 90% RH or less (No condensation) Storage temperature range 10C to 60C (No freezing) Storage humidity range 90% RH or less (No condensation) Insulation resistance Between all external terminals and the case: 50 MW (500 VDC) Weight 1050 g (Screw mounting), 1100 g (DIN rail mounting) *1 Do
" 0.006 8.3 Note 2) Rotating torque under pressure 0.5 MPa Note 3) Do not use the fittings with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.
When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc. When washing the element, do not wipe it using a stiff brush or rag. Refer to page 529 for Microswitch for differential pressure indication switch. r Removing the element Rotate the air breather (cap) one-third of a turn counterclockwise and remove it.
Please do the vacuum aspiration according to customer's specification.
Please do the vacuum aspiration according to customer's specification.
Do not bring objects that are sensitive to magnetism near the cylinder. The magnet is built into the cylinder. Do not bring magnetic disks, cards or tapes near the cylinder. Data may be lost. 5. If the cylinder is operated vertically with heavy loads, measures must be taken to prevent rapid extension of the piston rod when starting to operate in the downward direction.
Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals, etc. will result in leakage or malfunction. 4. Do not dent or scratch the mounting surface of a body and a plate. The flatness of the mounting surface may not be maintained, which would cause an increase in sliding resistance. MGPW with Rubber Bumper 63 100 50 5.
Do not over tighten the lock nut.
Polyurethane TU0425 2.5mm 4mm Metric size q Do not forcibly connect piping that could apply a lateral force to the cylinder tube, as this could cause the cylinder tube to tilt and lead to a malfunction.
To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.
MX MXU Precautions on Handling Warning Mounting/Adjustment Caution MXS MXQ q Do not scratch or gouge the sliding portion of the guide rod by striking it with an object or getting an object trapped in it.
SQ2000 SQ1000 (1) (1) SQ2000 (2) (2) Bore 4 Bore 2 Bore 4.5 OFF position ON position
Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6
Do not apply excessive torque when turning the locking type manual override. (0.1 Nm or less) Locking lever type (Option) Push down completely on the manual override button with a small screwdriver. While down, turn clockwise 90 to lock it.
Contact Protection Boxes/CD-P11, CD-P12 Auto Switch Internal Circuits Reed switches
Free mount Speed controllers do not protrude from the top of the body. Top mount Bottom mount Side mount Wiring and piping direction can be selected depending on mounting conditions.
They do not guarantee an actual fixed range (expect approximately 30% dispersion).
There may be large variations depending on the surrounding environment (variations as much as 30%). 12 Compact Cylinder Series CQ2 Auto Switch Mounting Contact Protection Boxes/CD-P11, CD-P12 Auto Switches/Proper Mounting Position for Stroke End Detection D-Z7 and D-Z8 type switches do not have internal contact protection circuits.