Phase-A signal PAO /PAO 17 18 Encoder output pulse signals for two-phase pulse train with Phase-B signal 90 phase differential PBO /PBO 19 20 PCO /PCO 21 22 Phase-Z signal Origin pulse output signal Signal ground Connects to the 0 V pin on the control circuit of the PC or PLC...etc.
1 1/2 3/4 1 380 431 HAW55-20 1612 1038 366 150 1203 276 216 315 264 219 234 305 100 140 66 140 139 6.0 18 2 3/4 1 375 426 HAW75-20 2112 1538 366 150 1703 276 216 315 264 219 234 305 100 140 66 140 139 6.0 18 2 3/4 1 375 426 HAW110-30 1724 950 500 72 1210 365 267 303 356 200 Note 1 70 Note 1 195 8.0 18 3 1 1 1/4 395 459 Note 1) HAW110-30 is 220 HAW Series 6 4 1) Outer dimensions ATX-OM-F003E
Fluid Nil No L Yes Thread type*1 5 Steam Nil Rc A G B NPT Body material/Port size/Orifice diameter Symbol Body material Port size Orifice diameter A Bronze (CAC) *1 The thread type for the main piping and pilot piping is the same. 3/8 11 B 1/2 14 C 3/4 18 D Stainless steel 316L equivalent Pressure type 3/8 11 E 1/2 14 F 3/4 18 Nil Standard H High pressure Other Special Options Special Entry
Piping: 40 (Base Mounted Common SUP Common EXH), Stations: 18 Stations, A B Port Size: M5 (M5X0.8)
Type: -, Connection Method: -, Compressed Air Quality: General Dry Air, Connection Type: [NPT] NPT, Plumbing Thread Nominal: 1 1/4, Filtration Level: 5μm, Operating Environment: Standard, Operating Pressure Range(MPa): -, Flow Direction: [Right] From Left to Right, Drain Cock: [Manual] Manual, Bowl Material: [Metal with Level Gauge] Metal Case with Level Gauge, Bowl Guard: No, Size of Body
Type: -, Connection Method: -, Compressed Air Quality: General Dry Air, Connection Type: [G] G, Plumbing Thread Nominal: 1 1/2, Filtration Level: 5μm, Operating Environment: Standard, Operating Pressure Range(MPa): -, Flow Direction: [Right] From Left to Right, Drain Cock: [Auto Float Type] N.O. Automatic Drain, Bowl Material: [Metal with Level Gauge] Metal Case with Level Gauge, Bowl Guard
Solenoid Direction: Type 40: A Port Bottom Ported; Type 42: Opposite Side of A Port, Piping: A Port Bottom Ported, Stations: 18 Stations, Port Size: 1/8 NPTF, Bracket: -
Piping: Base Mounted Common SUP Common EXH, Stations: 18 Stations, A B Port Size: M5X0.8
Piping: Base Mounted, Stations: 18 Stations, A, B Port: NPTF1/8, Bracket: -
Piping: Base Mounted, Stations: 18 Stations, A, B Port: NPTF1/8
Piping: 40 (Base Mounted), Stations: 18 Stations, A, B Port: 01T (NPTF1/8)
Piping: 40 (Base Mounted), Stations: 18 Stations, A, B Port: 01T (NPTF1/8)
- (2-3-1) LECPA . 32 (2-3-2) LECPA . 32 (2-3-3) LECPA . 34 5.4 .36 5.4.1 .36 (1) .36 (2) .38 5.4.2 .40 (1) .40 (2) .41 6. .42 6.1 .42 (1) .42 (2) .44 (2-1) LECPLECA .44 (2-2) LECPLECA .45 (2-3) LECPA .46 6.2 .47 (1) .47 (2) .47 (3) .48 (4) .50 (5) .51 (6) .52 (7) .54 (8) .54 6.3 .56 (1) .56 (2) .56 (2-1) .56 (2-2) .56 (3) .57 (3-1) .57 (3-1-a) TB Ver1.**. 57 (3-1-b) TB Ver2.**. 58 (3-2) .59
LED PWR CN2 STAT CN2TB/PC BUS STAT IF ALM SF BF LED 10.LED ALM LED 7 12.LEC 9 - 3 31 DC24V10% 200mA 300mA LEC 5 57words 57word UL , UL1310 Class2 Profibus Profibus DP V1 DP slave 0125 ID 1414 GSD Dsub 9.6k 19.2k 45.45k 93.75k 187.5k 500k 1500k 12000k (bps) (m) 1200 1000 400 200 100 IF RS485(Modbus ) 115.2k 230.4kbps 115.2kbps 28m 3m 5m 5m 5m 5m 5m 10 - 0 40
UL (CSA) Weight 20 g 40 g 55 g (for M8 connector socket) EX9-AWES (2 pcs.) EX9-AWES (8 pcs.)
Table 4 20 25 32 40 Rod seal CM20Z-PS CM25Z-PS CM32Z-PS CM40Z-PS The rod seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year.
Cooling capacity2 [kW] 9 18 19 18 26 18 Heating capacity3 [kW] 1.5 1 4.5 1 6.5 1 Temperature stability4 [C] CH1: 0.1/CH2: 0.5 Rated ow (Outlet) [L/min] 45 (0.43 MPa) 10 (0.45 MPa) 45 (0.45 MPa) 10 (0.45 MPa) 125 (0.45 MPa) 10 (0.45 MPa) Maximum ow rate [L/min] 120 16 130 16 180 16 Maximum pump head [m] 50 49 55 49 68 49 Settable pressure range5 [MPa] 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55
. <> UPDOWN[F 6] SET UP DOWN SET [F 6] -37No.PS-OMV0003CN-G [F10] 39 <> UPDOWN[F10] SET UP DOWN 2 OFF (OUT1) (OUT2) [dUAL]2 SET () [LinE] SET () () 40 () UP DOWN () SET , (SET ) SET () [dUAL]2 SET () AbY(Z) 40 () 019 ( ) UP DOWN / () SET 1 () SET SET [F10] -38No.PS-OMV0003CN-G <> UPDOWN (OFF) OUT1 OUT1 OUT2 OUT2 ( OFF ) (n_1) n_2 OFF [F10 ] () ()
Plate mounting support bracket Body mounting side support Auto switches mountable (both sides) Types of Units and Parts Type of units and parts Type of units Type of parts Single units P.1 to P.9 Combination units P.11 to P.18 Set parts P.11 to P.14 Parts P.16 Spare parts P.4 & 5 Optional parts P.2 Catalog pages Parts for combination units.
Note 19 - CRJU05~1 11 8 6 12 4 10 3 10 18 11 14 7 9 1 13 15 17 16 2 17 15 14 18 18 Hexagon socket head set screw 2 17 Wear ring 2 16 Magnet 2 15 Piston seal 2 14 O-ring 2 13 Hexagon nut 2 12 Round head no. 0 Philips screw 3 11 Hexagon socket head cap screw 4 10 Bearing 2 9 Hexagon socket head set screw 2 8 Stopper retainer 1 7 Holder 1 6 Stopper 1 5 Cover 2 4 Bearing retainer 1 3 Shaft