Unless otherwise described particularly, 50M (Min) is used for auto switch. Insulation resistance Magnetic field resistant auto switch An auto switch, for which measures against effects arising from external (welding) magnetic field generated in the spot welding process, etc. are taken. The solid state auto switch functions as it detects the frequency of the applied magnetic field.
Resolution 0.1mm/pulse Accuracy 0.2mm Note 1) Output type Open collector (Max.DC30V, 50mA) Output signal A/B phase difference output Insulation resistance DC500V, 50M or more (between case and 12E) Vibration resistance 33.3Hz 6.8G 2hrs. each in X and Y directions 4hrs in Z direction based upon JIS D1601 Impact resistance 30G 3 times each in X,Y and Z directions Enclosure IP65 (IEC Standard
Confirm locations of alert warning and caution labels. 500 500 Voltage interruptions 20ms or less Facility water temp. 10deg.C Insulation resistance 50M or more (DC500V) 0 0 Do not service machinery/equipment or attempt to remove Over voltage category Category II 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 Pollution degree Pollution degree II Circulating fluid temp. deg.C Circulating fluid
Common Specifications Reed switch Solid state switch Style None 3 wire style: 100 mA or less 2 wire style: 1mA or less Current leakage 1 ms or less (2) 1.2ms Operating time 300m/s2 1000m/s2 Shock resistance 50M or more at 500V DC (Electrical wire, Between bowls) Insulation resistance 1 minute at 1500V AC(1) (Electrical wire, Between bowls) 1 minute at 1000V AC (Electrical wire, Between bowls
drain : 1/4 (with a plug) Radiating water side:SUS303, SUS304 Recirculating fluid side: SUS303, SUS304, EPDM, Ceramic, PPS glass 30%, Wetted materials Carbon, Polyethylene, Polyurethane Power supply voltage Single phase AC200 to 220V, 50/60Hz Current consumption MAX 5A Max. sound pressure 62 dB Inrush current 50A or less Over current protection 10A circuit protector Insulation resistance 50M
Double Acting, Single Rod Mass Unit (g) Cylinder stroke (mm) Size 5 10 15 20 25 30 35 40 45 50 75 100 20 105 115 125 134 144 153 163 173 182 192 25 127 138 148 159 169 180 190 201 211 222 32 199 214 228 243 257 272 286 301 315 330 402 475 40 264 282 299 316 333 351 368 385 403 420 506 593 Additional Mass Unit (g) Size 20 25 32 40 32 32 19 Male thread 19 How to Calculate (Example) CQUD32-50M
Incremental type) Magnetic field resistance 14.5mT Power supply DC12V10% (Power supply ripple : Less than 1%) Current consumption 40mA Resolution 0.1mm / pulse Accuracy 0.2mm (20) Note1) Output method Open collector (DC35V, 80mA) Output signal Phase A/B phase difference output Max. response speed 500mm/s Withstand voltage AC500V, For one minute (Between case and 12E) Insulation resistance DC500V, 50M
22.5 43 6.5 27 22.5 53 6.5 37 MIW12-12D MIW20-20D 6 4 4 2 18.5 29 6.5 20.5 31 8.5 MIS12-10D MIS20-10D 4 2 6 4 2.5 4 18.5 39 6.5 20.5 41 8.5 MIS12-20D MIS20-20D 6 4 4 2 18.5 49 6.5 20.5 51 8.5 MIS12-30D MIS20-30D 6 4 4 2 13 Series MIW/MIS Auto Switch Common Specifications Auto Switch Common Specifications Solid state switch Type 1ms or less Operating time 1000m/s 2 Impact resistance 50M
Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Model L A B n D E Without lock With lock LEFS32Em-50m 332 384 56 180 4 LEFS32Em-100m 382 434 106 230 4 LEFS32Em-150m 432 484 156 280 4 LEFS32Em-200m 482 534 206 330 6
Example) D-Y59AL Impact resistance 1000m/S Insulation resistance 50M or more at 500VDC (between lead wire and case) Withstand voltage 1000VAC for 1min.
Enclosure IP40 Operating temperature -5 to 50C range Environmental resistance Withstand voltage 1000 VAC for 1 minute between terminals and housing 50M or more between terminals and housing Insulation resistance (with 500 VDC megger) Temperature characteristics 2% F.S.
Enclosure IP40 Environmental Withstand voltage 1000 VAC for 1 minute between terminals and housing resistance 50M or more between terminals and housing Insulation resistance (with 500 VDC megger) Temperature characteristics 2% F.S.
Mounting clearance (mm) Bore size (mm) 40 20 46 25 56 32 Clearance 6 Series CU Auto Switch Specifications Auto Switch Common Specifications Type Reed switch Solid state switch Leakage current None 3-wire: 100A or less; 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m/s 50M or more at 500VDC (between lead wire and case) 1000m/s Insulation resistance 1500VAC for
With shielding plate 6 8 10 Bore L d 16 3 13.5 0.5 14 0.5 10 Series CUJ Auto Switch Common Specifications Auto Switch Common Specifications Type Solid state switch Operating time 1ms or less Impact resistance 1000m/s Insulation resistance 50M or more at 500VDC (between lead wire and case) 1000VAC for 1min.
Bore size (mm) Applicable switch Reed switch Solid state switch Bore size 20 25 32 40 50 63 80 100 Series Contents Order number RQB20-PS RQB25-PS RQB32-PS RQB40-PS RQB50-PS RQB63-PS RQB80-PS RQB100-PS Bracket no.
Load Load Internal Current Applicable voltage consumption voltage current voltage drop leakage load DC28V 40mA 1.5V D-F8N NPN Type or less or less or less DC24V 100A or DC512 10mA Relay less at 24V or less PLC DC24V (4.5to 28V) IC circuit type 80mA 0.8V D-F8P PNP or less or less DC24V 0.8mA or DC24V 2.5 to 4V D-F8B (DC10 less at Relay 40mA or less to 28V) DC24V PLC Isolation resistance 50M
B B For D-F8 Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch Lm 6 Series CRJ Auto Switch Common Specifications Auto Switch Common Specifications Solid state switch Type 1ms or less Operating time 1000m/s Impact resistance 50M or more at 500VDC (between lead wire and case) Insulation resistance 1000VAC for 1min.
Note 3) Refer to "Specific Product Precautions [Cushion Effect (Sine Cushion) and Stroke Adjustment] on page 22. 4 Series CYP Auto Switch Common Specifications Auto Switch Common Specifications Type Solid state switch Reed switch 3 wire: 100A or less, 2 wire: 0.8mA or less Leakage current None Operating time 1ms or less 1.2ms Impact resistance 1000m/s {102G} 300m/s {30.6G} 50M or more at
If work is held around the end position of finger opening stroke, the above detecting combination may be limited due to the ON/OFF differential of the auto switches. 24 Series MHF2 Auto Switch Common Specifications Auto Switch Common Specifications Solid state switch Type 1ms or less Operating time 1000m/s 2 Shock resistance 50M or more at 500VDC (between lead wire and case) Insulation resistance
Precautions [Cushion Effect (Sine Cushion) and Stroke Adjustment] on page 22. 7 Series CYP Clean Room Rodless Cylinder Auto Switch Common Specifications Auto Switch Common Specifications Solid state switch Reed switch Type 3 wire: 100A or less, 2 wire: 0.8mA or less None Leakage current 1ms or less 1.2ms Operating time 1000m/s {102G} 300m/s {30.6G} Impact resistance Insulation resistance 50M