Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
CVM5/CVM5K MXU 20 Standard 3.5-18 Double acting 25 MXS 3.5-29 32 Nonrotating rod 40 MXQ MXF Series CVM3/CVM3K 20 Standard MXW Single acting 3.5-34 25 (Spring return) 3.5-47 32 Nonrotating rod (Spring extend) MXP 40 MG Series CV3/CV3K 40, 50 63, 80 100 MGP 3.5-52 Standard Double acting MGQ Nonrotating rod 40, 50 63 3.5-63 MGG MGC Series CVS1/CVS1K 40, 50 63, 80 100 3.5-67 Standard MGF Double
Description Material Note w y 1 Union nut Fluoro coated Stainless steel 316 2 Male connector body Stainless steel 316 t 3 Male elbow body Stainless steel 316 Swivel elbow body Stud 4 Stainless steel 316 5 Stainless steel 316 O-ring 6 Special FKM Fluoro coated Male connector Male elbow Swivel elbow 322 KFG2 Series Stainless Steel 316 Insert Fittings Applicable Tubing: Metric Size, Connection
Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3
Writing registers.3-13 3.11.3 Function code: 16 Writing multiple registers .3-15 3.12 Negative response . 3-16 3.13 Register map . 3-18 HRS400-A-46 DOC1003626 Contents 3.13.1 Circulating fluid discharge temperature . 3-19 3.13.2 Circulating fluid flow rate . 3-19 3.13.3 Circulating fluid discharge pressure . 3-19 3.13.4 Circulating fluid electrical conductivity . 3-19 3.13.5 Status flag . 3-20
Writing registers .3-14 3.11.3 Function code16 Writing multiple registers .3-15 3.12 Negative response . 3-16 3.13 Register Map . 3-18 HRL Series HRX-OM-W069 Contents 3.13.1 Circulating fluid discharge temperature . 3-19 3.13.2 Circulating fluid electrical conductivity . 3-19 3.13.3 Circulating fluid discharge pressur . 3-19 3.13.4 Circulating fluid flow rate . 3-19 3.13.5 Status flag . 3-20
3.13.6 Circulating fluid set temperature . 3-20 3.13.7 Operation instruction . 3-20 3.13.8 Data instruction . 3-21 Chapter 4 Communication alarm function . 4-1 4.1 COMMUNICATION ALARM OCCURS . 4-1 4.2 COMMUNICATION ALARM RESET . 4-2 4.3 SETTING METHOD . 4-2 HRLE Series HRX-OM-Z015 Chapter 1 Read before using Chapter 1 Read before using The communication of this product consists of contact
High temp. cut off alarm ERR12 Low temp. cut off alarm ERR13 Unused Output failure alarm ERR15 D2 23 22 21 20 Upper temperature limit alarm WRN Lower temperature limit alarm WRN Thermostat alarm ERR14 DC power supply failure alarm ERR11 D3 23 22 21 20 External sensor failure alarm ERR18 Internal sensor failure alarm ERR17 During Auto tuning or auto tuning warning ERR19 Flow switch alarm