(mm) Effective area (mm2) Urethane Soft nylon L M1 Weight (g) D M2 Model a b Applicable thread Applicable thread a b KAH23-04 32.5 34.5 38.5 18.5 21 4 3.2 6 4 15.5 16 17 18.5 20.9 10.4 12.8 15.2 16 17 18.5 28.2 28.2 16.7 16.7 6 4 3 KAH04-06 KAH06-08 10.7 10.7 4.2 4.2 3.2 2.7 8 6 10 8 KAH08-10 42 44.5 21 22 11 14 KAH10-12 10 12 15-3-23 Series KA Union Elbow: KAL Effective area (mm2) Urethane
Nylon Tubing Series T/TIA For general pneumatic tubing, Nylon tubing Model/Specifications 20 m roll 100 m roll (T1613 is reel.) Tubing size Metric size (Series T) Inch size (Series TIA) Burst Pressure Characteristics Curve and Operating Pressure TIA01 T0425 T0403 T0604 T0645 T0806 T1075 T1209 T1613 TIA05 TIA07 TIA11 TIA13 Model Tubing O.D.
MR-J3-T if using the LECSC. MR-J3-B if using the LECSS. MR-J4-B or MR-J4-B(-RJ) if using the LECSS-T. Please select servo amplifier connection USB as the communication device. Click OK. Click OK. 7 - 1.2.4 Driver ON LINE Check Check that the driver is enabled (ONLINE). Check that the ONLINE/OFFLINE icon is displayed .
code, Socket, Straight 2 m, SPEEDOCON compatible PCA-1564930 Cable with M12 connector, B code, Socket, Straight 6 m, SPEEDOCON compatible PCA-1564943 Cable with M12 connector, B code, Socket, Right angle 2 m, SPEEDOCON compatible PCA-1564969 Cable with M12 connector, B code, Socket, Right angle 6 m, SPEEDOCON compatible (9)DeviceNetTM communication cable PCA-1557633 Cable with M12 connector
Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.
Dimensions: Stroke Adjusting Bolt (mm) Applicable size Model Stroke adjustable range (mm) A B C M M C MXF-A827 MXF-A827-X11 MXF-A1227 MXF-A1227-X11 MXF-A1627 MXF-A1627-X11 MXF-A1627-X12 MXF-A2027 MXF-A2027-X11 MXF-A2027-X12 5 15 5 15 5 15 25 5 15 25 17 27 23.5 33.5 26.5 36.5 46.5 30 40 50 MXF8 M4 x 0.7 6 2 MXF12 M5 x 0.8 7 2.5 MXF16 M6 x 1 8 3 A B MXF20 M8 x 1 12 4 8-6-9 10 Series MXF Dimensions
T he pump may stop due to unstable operation w ith discharge flow less than the minimum discharge flow . C ircuit(1 ) C ircuit(2 ) Pilot valve set K T PA 5 3 8 NBR diaphragm set K T PA 3 3 2 PT F E diaphragm set K T PA 3 3 1 S w itching valve assembly set K T PA 3 3 6 A ctuator parts set K T PA 3 3 7 4 . Maintenance 3 .
set K T PA 5 3 1 C heck valve set K T PA 5 3 6 S w itching valve set K T PA 5 3 7 4 .
C a u t i o n ~ When replacing seals, take care not to hurt your hand or finger on the corners of parts. 17 3-2-1. Disassembly / Reassembly C a u t i o n ~ Disassemble and assemble the cylinder on a clean cloth in a clean location. Perform on a clean cloth.
The straight piping length shall be 8 cm or longer in order to maintain 3%F.S. of the specification. -66No.PF-OMP0002-H Dimensions (in mm) PFMB7501/7102/7202 Symbol Model A B D E F H K L N PFMB7501/7102 70 30 43.7 37.2 15 14 26 18 13.6 PFMB7202 90 35 49.2 42.7 17.5 24 31 28 16.8 Bracket dimensions Symbol Model S T U V W PFMB7501/7102 24 22 32 40 50 PFMB7202 30 30 42 48 58 -67No.PF-OMP0002
If a bend (R) is used, limit it to R2 or less. -54No.PF-OMN0005-E Bracket (ZS-28-B) Power and output lead wire and connector (ZS-28-A) -55No.PF-OMN0005-E Revision history A: Contents revised in several places. B: Error correction. (page 28) C: Contents revised in several places. D: Contents revised in several places. [September 2016] E: Contents revised in several places.
W&F Contact B OUT6 N/A Output signal: OFF (open) for normal operation 4 OUT1 to OUT6 Contact A, B Output signal A: Contact A, B: Contact B Same as above Used to display the 5 [Enter] key MESSAGE screen to accept the setting. Used to display the MESSAGE screen to initialize the settings of RUN, REMOTE, and 6 [Initial] key OUT1 to OUT6. 7 [Cancel] key Used to cancel the setting.
CJP Rear trunnion Integrated clevis Boss-cut basic Basic Axial foot Front flange Rear flange Single clevis Double clevis Front trunnion T E BZ B L F G C D U CJ2 F Low friction direction Boss-cut front flange FZ CM2 Side at pressure When pressurized on head side Boss-cut front trunnion B Side at pressure When pressurized on rod side UZ C85 CG1 L 40 150 CM2Q F Standard MB C95 CDM2Q L F 40 C73
4 r t e !6 Parts list Parts list Note Material No. Description No.
High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when work piece is vacuumed. Min.B : Maximum pressure value when work piece is not vacuumed.
W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/
R 3 VDC 8 One-touch fitting C8 10 One-touch fitting 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting 2(B) (A)4 Rated voltage 10-SY7000 C10 C8 C10 C12 3 For AC ( Hz) 50 60 Thread type (EA)5 1 (P) 3(EB) 1 100 VAC 2 200 VAC 10-SY9000 Rc Nil 3 position exhaust center F G 2(B) (A)4 3 110 VAC [115 VAC] N NPT One-touch fitting (Inch size) 4 4 220 VAC [230 VAC] NPTF T Symbol Port size
DIN type is available with class B only. Refer to the Table (3) for the available combinations between each electrical option (S, L, Z) and rated voltage. Option S, Z are not available because a surge voltage suppressor is integrated into the AC/Class B, built-in full-wave rectifier type as a standard. Table (1) Model/Orifice Size/Port Size Normally Closed (N.C.)