F_1 and F_2 have setting ranges of 0-90%F.S. and 10-120%F.S., respectively. However, the set pressure exceeds rated output; 100F.S. is out of warranty. (refer to Fig.2,3) The values are necessary to satisfy F_1 + 10%F.S. < F2. If not, the previous values are reflected in this function. Default of Zero adjusting: 0x0 Bit Bit 13 (It is Bit 12 up to 100%.)
CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
Indicator light Output 1 and 2: Orange Power supply Used as switch output device 12 to 24 VDC, including ripple (p-p) 10% voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 50 mA max.
Remarks Weight Lead wire and M12 connector LFE-1-A3 Lead wire length: 3 m Approx. 175 g LFE-1-D Tapping screw 3 x 10, 4 pcs. Approx. 45 g Bracket LFE-2-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs.
LCD 4.DIN 30mm 30mm 10 - 2-2 30mm No. 2-3 (1), (Err6), 1 ML2B25 15 ML2B32 19 ML2B40 24 2-4 5mm 5-10-15 5mm Err5 4.2 5 10 15 20 1.0 1.0 1.0 1.0 5.8 5mm30mm Err6: 20 30 100mm/sec :50cm :0.5MPa 11 - 3 3 3 3 ML2B+CEU2 NO 1 () () YES NO () YES NO YES YES NO YES NO YES YES NO NO NO YES A 12 - A 1.
CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
Standard Stroke 2 , 3 , 4 , 5 , 6 , 8 , 1 0 2, 3, 4, 5, 6, 8, 10 5, 10, 15,20,25,30 5, 10, 15,20,25,30,40 5, 10, 15, 20,25, 30, 40 5, 10, 15,20,25,30,40 1 kg=2.2 16. Magnetic Holding Power (lbs) 1N=0.101 H 227.94 L type 140.65 Basicweight. -. -. 8.00 lb6) Additional weight.. . 0.30/1 inch !
Standard Stroke 2 , 3 , 4 , 5 , 6 , 8 , 1 0 2, 3, 4, 5, 6, 8, 10 5, 10, 15,20,25,30 5, 10, 15,20,25,30,40 5, 10, 15, 20,25, 30, 40 5, 10, 15,20,25,30,40 1 kg=2.2 16. Magnetic Holding Power (lbs) 1N=0.101 H 227.94 L type 140.65 Basicweight. -. -. 8.00 lb6) Additional weight.. . 0.30/1 inch !
Option R . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 EARTH LEAKAGE BREAKER SPECIFICATION . 10-1 10.3 CONNECTION OF POWER SUPPLY . 10-2 Chapter 11 Option T .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 OPERATION / ERROR SIGNAL OUTPUT . 11-1 11.3 REMOTE OPERATION . 11-2 11.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 11-3 11.5 ELECTRIC CIRCUIT . 11-4 Chapter 12 Option V . 12-1
AMX-OMZ0095 PRODUCT NAME Activated Carbon Filter MODEL / Series / Product Number AMK50-(F,N)06 ~ (F,N)10(B)(-R,Z)-D AMK60-(F,N)10(B)(-R,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 6-1. Bowl assembly for AMK50 10 6-2.
Standard Stroke 2 , 3 , 4 , 5 , 6 , 8 , 1 0 2, 3, 4, 5, 6, 8, 10 5, 10, 15,20,25,30 5, 10, 15,20,25,30,40 5, 10, 15, 20,25, 30, 40 5, 10, 15,20,25,30,40 1 kg=2.2 16. Magnetic Holding Power (lbs) 1N=0.101 H 227.94 L type 140.65 Basicweight. -. -. 8.00 lb6) Additional weight.. . 0.30/1 inch !
-01 Round type pressure gauge Rc G46-4-01 1 0.2MPa setting G46-10-N01 G46-4-N01 1 0.2MPa setting Z Imperial unit Name plate psi Pressure gauge MPa / psi G46-P10-N01-X30 NPT Imperial unit Name plate psi Pressure gauge MPa / psi 0.2MPa setting G46-P4-N01-X30 1Z G46-10-01 G G46-4-01 1 0.2MPa setting G46-10-01-L Round type pressure gauge (with colour zone) Rc G46-4-01-L 1 0.2MPa
Bore d C B H NTJ-015A 10 16 8.1 9.2 7 8 3.2 4 M4 X 0.7 NTJ-010A M5 X 0.8 * Refer to p.1.3-12 for details of the mounting nut. (mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
AS321FE AS331FE AS421FE AS431FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D.
Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid
For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. Unit s selection function is not available for fixed to SI units type.
-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 8 10 10 12 12 12 16 16 1 1.5 1 1.25 1.5 1.75 1.5 2 D-X Technical Data 1139 JC Series Dimensions of Accessories Rod end nut (mm) d: Thread nominal size Model Order number M8 x 1 M8 x 1.25 M10 x 1 M10 x 1.25 M10 x 1.5 M12 x 1.25 M12 x 1.5 M12 x 1.75 M14 x 1.5 M16 x 1.5 M16 x 2 M18 x 1.5 H 5 5 6 6 6 7 7 7 8 10 10 11
Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12.
Assembly and disassembly of the SI unit -35No.EX-OMP0013-E Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Pollution
The voltage variation must stay within the 10% to +10% range of the rated voltage. In case importance is attached to response characteristics due to use of a DC power source, keep the variation within the 5% to +5% range. The voltage drop is the value at the lead wire to which the coil is connected.