Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 09
JIS Standard Hydraulic Cylinder/Double Acting, Double Rod Series CH2EW/CH2FW 32, 40 50, 63 80, 100 Replacement Procedure is P.396 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
JIS Standard Hydraulic Cylinder/Double Acting, Single Rod Series CH2E/CH2F/CH2G/CH2H 32, 40 50, 63 80, 100 Replacement Procedure is P.396 Construction @9 @2 @4 @7 @8 @6 @1 #0 @3 @5 The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CH2E/CH2F/CH2G/CH2H. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No.
Tie-rod Type Hydraulic Cylinder/Double Acting, Single Rod Series CHA 40, 50, 63, 80 100, 125, 160 Construction !8 !9 @2 @3@0 !7 @1 @2 40 The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CHA. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Seal kit no. Content Bore size (mm) CHA40-PS 40 50 63
Tie-rod Type Hydraulic Cylinder/Double Acting, Double Rod Series CHAW 40, 50, 63, 80 100, 125, 160 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !6 !7 @0 @1 !8 @2 !9 @0 40 The numbers are the same as the "Construction" of the Best Pneumatics
JIS Standard Compact Hydraulic Cylinder Series CHKD 20, 25 32, 40 50, 63 80, 100 Replacement Procedure is P.392 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !0!1 !3 !
Compact Hydraulic Cylinder Series CHKG 20, 25 32, 40 50, 63 80, 100 Replacement Procedure is P.393 Construction !1 !3 !4 !2 u 32 to 100 Without auto switch The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CHKG. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Seal kit no.
Hydraulic Cylinder Series CHN 20, 25, 32, 40 Replacement Procedure is P.394 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !7 !6 @0 !8 @1 !9 @2 The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CHN.
Compact Hydraulic Cylinder/Double Acting, Single Rod Series CHQB 20, 32, 40 50, 63, 80, 100 Construction CHQB20 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !0 !3 !2 !1 CHQB32 to CHQB100 o !0 !2 !1 !3 The numbers are the same as the "Construction
Compact Hydraulic Cylinder/Double Acting, Double Rod Series CHQWB 20, 32, 40 50, 63, 80, 100 Construction CHQWB20 !0 !3 !2 !1 CHQWB32 to CHQWB100 o !0 !2 !1 !3 The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CHQWB. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Seal kit no. Content Bore size
ISO Standard Hydraulic Cylinder Series CHSD Replacement Procedure is 40, 50, 63 80, 100 P.395 Construction CHSDB @4 @5 @9 @6 @2 @3 @1 @7 @8 The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CHSD. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Seal kit no.
ISO Standard Hydraulic Cylinder Series CHSG Replacement Procedure is 32, 40, 50 63, 80, 100 P.395 Construction CHSGB Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 09
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Vacuum Ejector, ZK2, VACUUM EJECTOR, 99.00000 lb
Vacuum Ejector, ZK2, VACUUM EJECTOR, 99.00000 lb
Vacuum Ejector, ZK2, VACUUM EJECTOR, 99.00000 lb