The power supply voltage between the power supply terminal PWR_24V and PWR_GND is outside of DC24 V +/10%. Power supply Use a power supply voltage of DC24 V+/-10%. PWR LED: error PWR signal: 1 Green flashing Continue OFF (Outside of 24 (Cycle: 1 Hz) V+/-10%) The power supply voltage between the power supply terminal PWR_24V and PWR_GND is below 17 V.

Specifications Model MSUA1 MSUA3 MSUA7 MSUA20 Vane Type Single vane Rotating angle *1) 90 o 180 o 90 o 180 o 90 o 180 o 90 o 180 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o Fluid Air (Non-lube) Proof pressure 1.05 MPa 1.5 MPa Ambient and fluid temperature 5 to 60 oC Operating pressure range 0.2 to 0.7 MPa 0.15 to 0.7 MPa 0.15 to 1.0 MPa Rotation time adjustment range 0.07 to

Body pin hole Size Tightening torque 10 0.2 to 0.3Nm 15 0.3 to 0.5Nm 20 4.2 to 5.2Nm 30 4.2 to 5.2Nm 40 7.2 to 8.7Nm Size 10 , 15 Cover Assembly End cover Assembly Body pin hole Hexagon socket head bolt Fig.22 Size 20 , 30 , 40 (6) Perform operation test after assembling and check external leakage.

Model Screw Max. tightening Maximum screw-in depth (L mm) torque (Nm) MHZ2-10 M3 x 0.5 0.9 6 MHZ2-16 M4x0.7 1.6 4.5 MHZ2-20 M5 x 0.8 3.3 8 L L MHZ2-25 M6x1 5.9 10 MHZ2-32 M6x1 5.9 10 MHZ2-40 M8 x 1.25 13.7 13 Model Screw Max. tightening torque (Nm) Maximum screw-in depth (L mm) MHZ2-10 M3 x 0.5 0.69 5 MHZ2-16 M4x0.7 2.1 8 MHZ2-20 M5 x 0.8 4.3 10 MHZ2-25 M6x1 7.3 12 MHZ2-32 M6x1 7.9 13 MHZ2

218 210 to 420 Max. speed[mm/s] *1 *3 400 200 100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line

1122Series MXP/MXPJ6 Air slide table 6, 10, 12, 16 How to Order Clean series 11 Vacuum suction type MXP 11 12 15 M9N MXP 22 12 15 M9N Copper, fluorine and silicon-free + low particle generation Number of auto switches Nil s n 2 pcs. 1 pc. n pcs. 22 Vacuum suction type Bore size Stroke mm Type of auto switch 6 10 12 16 5, 10 10, 20 15, 25 20, 30 Nil Without auto switch Refer to the table

10 0 20 40 60 80 100 0 0 0 50 100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC74 6 ZFC75 8 0.1 MPa 0.3 MPa 0.5 MPa 0.1 MPa 0.3 MPa 30 30 Differential pressure [kPa] Differential pressure [kPa] 0.5 MPa 0.7 MPa 20 20 0.7 MPa 10 10 0 50 100 150 250 200 0 0 0 100 200 300 400 500 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC76 10 ZFC77 12 0.1 MPa 0.3 MPa 0.1 MPa 0.3 MPa 30

Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% PS port 2(B) Vacuum pad port Flow Characteristics Response Time Flow Characteristics (When restrictor is fully open) 2(B)3/5(E) 1(P)2(B) b 0.19 Cv 0.05 C [dm3/(sbar)] 0.40 b 0.18 Cv 0.10 C [dm3/(sbar)] 0.24 Valve model Fluid passage 2(B) Port size M5 Valve model Response time ms (at 0.5 MPa) SJ3A6-ll-l

Electric Actuators Precautions . 10 2.1 Wiring/Cables . 10 2.2 Design/Selection . 11 2.3 Mounting . 12 2.4 Handling . 13 2.5 Operating Environment . 15 2.6 Maintenance . 15 2.7 Actuator with Lock . 16 2.8 Design/Selection . 17 2.9 Handling . 17 2.10 Mounting . 18 2.11 Power Supply . 19 2.12 Grounding . 19 2.13 Wiring . 19 2.14 Maintenance . 20 3.

LED display.31 9. 1 LED display.31 9. 2 Controller IF communication status and LED display.32 10. Mode.33 10. 1 Outline.33 10. 2 Step data input mode .33 10. 3 Numerical data input mode.33 10. 4 Data writing mode.35 11. Memory map .36 11.1 Memory assignment.36 11.2 Controller IF flagIN Data.40 11.3 Gateway unit status flagIN Data.40 11.4 Gateway unit control flagOUT Data.42 12.

Wetted materials Stainless steel, EPDM, NBR, Ceramic, PPE, PPS, Carbon, Polyethylene, POM 10 Temperature Alarm Common cable connected to this connector. Required flow rate 10 to 15 L/min Facility water 11 Temperature Alarm b contact 3.3.2 Heating Capacity Temperature range 10 to 35 C 5 (CLOSE During Alarm) system Only trained personnel should handle or operate the product.

Manual unlocking P14 10. Maintenance P16 10-1. Disassembly/ Replacement 10-2. Maintenance 10-3. Construction 11. Auto switch P19 11-1. Applicable auto switches 11-2. Minimum auto switch mounting stroke 11-3. Auto switch proper mounting position (detection at stroke end) and its mounting height 11-4. Auto switch operating range 11-5.

The allowable voltage fluctuation rate is 10% of the rated voltage value for both AC and DC.

Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR

70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.

Screw torque (Nm) depth (mm) MHZJ2-10 M3 x 0.5 0.9 6 MHZJ2-16 M4x0.7 1.6 4.5 MHZJ2-20 M5 x 0.8 3.3 8 MHZJ2-25 M6x1 5.9 10 Max. tightening torque (Nm) Maximum screw-in Model No. Screw depth (mm) MHZJ2-10 M3 x 0.5 0.69 5 MHZJ2-16 M4x0.7 2.1 8 MHZJ2-20 M5 x 0.8 4.3 10 MHZJ2-25 M6x1 7.3 12 Max. tightening Model No.

Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR

Stations Fitting Barb fitting One-touch fitting PV060-10-8A PV060-10-7A PV060-10-10A PV060-10-9A 4 stations Connector cable length 8 stations Nil 6 10 300 mm Barb fitting is included. One-touch fitting is mounted on the plate. 600 mm Note 1000 mm Insertion error checking ridge If only the fitting is needed, order with one of the part numbers below. e Fitting Part No.