30.5 32.5 30 50 50 41 42 48 44.5 47.5 43.5 36.5 38.5 36 63 56.5 47.5 48.5 54.5 51 54 50 40 42 39.5 10-10-13 14 Series RZQ Mounting of Auto Switch Follow the procedures below to mount auto switches.
A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,
Acknowledgment and restart . 38 3 No.EX##-OMY0011-A Appendix A: Glossary for PROFIsafe . 39 Appendix B: Parameters for PROFIsafe . 41 Appendix C: Checklists . 42 Appendix D: Safety Characteristics . 47 Appendix E: EX260-FPS Timing Values . 48 Appendix F: Failure modes . 49 4 No.EX##-OMY0011-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or
Addresses 0hex and Fhex are not permitted. 66 42 Correct value. 67 43 Invalid parameterization of F_WD_Time. A monitoring time of 0 ms is not permitted. Correct value. Invalid parameterization of F_SIL. The safety module (F-Module) cannot support the required SIL. Use a module with the required SIL.
Safety Mode (Channel Passivation) Safety Mode (Module Passivation/xxx)10.6 42 No.EX##-OMY0006CN Output feedback parameter SI Table 8-5 Output feedback parameter Enable Table 8-5 No. Bit (*) Bit (*) 1 0 I/O M 0 0 IN0 [0 and 4] 2 1 zone1 Z1 1 1 IN1 [1 and 5] 3 2 zone2 Z2 2 2 IN2 [2 and 6] 4 3 zone3 Z3 3 3 IN3 [3 and 7] (*) 10.9.2 LED 2 43 No.EX##-OMY0006CN 9. 9.1.
When the output specification of the copy destination display setting device is not 6, the output specification should be set to copy input in accordance with the [F 5]FUNC terminal setting (page 42) beforehand.
For details of each setting, refer to page 17 to 42 of this manual. The Pressure switch is compulsory turned off for 1 seconds after power supplied. For 4 seconds after supplying power, the measurement output is turned off. Maintenance Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance.
Accumulated pulse output is selected: Refer to page 42 d. Error output is selected: Refer to page 43 e. Output OFF is selected: Refer to page 43 Press the SET button to set. Return to function selection mode.
Nominal thread size Tightening torque Rc(NPT)3/8 15 to 20 Nm Rc(NPT)1/2 20 to 25 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm Rc(NPT)1 1/4 40 to 42 Nm Rc(NPT)1 1/2 48 to 50 Nm If the tightening torque is exceeded, the product can be broken. If the correct tightening torque is not applied, the fittings may become loose. Avoid any sealing tape getting inside the piping.
(page 141) -142No.PF-OMA1007-B Air Management Hub Base type EXA1-20/30/40-PN/EN/EC-# Model A B C D E F EXA1-20 236.2 35 42 19.1 65.1 30.5 EXA1-30 236.2 43 53 13.6 65.1 30.5 EXA1-40 240.4 51 64.4 4.6 71 35.5 -143No.PF-OMA1007-B EXA1-60-PN/EN/EC-# -144No.PF-OMA1007-B Remote type EXA1-20/30/40-SA-# Model A B C D E F G EXA1-20 236.2 35 42 19.1 65.1 30.5 74.7 EXA1-30 236.2 43 53 13.6 65.1 30.5
Therefore, the seal kit includes 42 (large cushion seal) and 43 (small cushion seal) . Please check the specification before use and select suitable cushion seal. C a u t i o n The seal is not delivered in sealed packaging for independent storage, so it must be used within 1 year. 4-1-2.
Therefore, the seal kit includes 42 (large cushion seal) and 43 (small cushion seal) . Please check the specification before use and select suitable cushion seal. C a u t i o n The seal is not delivered in sealed packaging for independent storage, so it must be used within 1 year. 4-1-2.
After assembly is completed, perform an operation test and check that there is no air leakage. 17 10 14 15 3 5 27 11 12 6 9 14 1 4 11 9 27 2 4 19 15 Cushion seal 8 Body Left cover Rack 18 Direction of the shaft(key) About10 Fig. (17) Direction of assembly of the shaft 42 - . Size 50 to 100 Disassembly procedure 1.
The response will be slower because of this. 42 No.JXC-OMY0002-A 7.3 Return to origin parameter The "Return to origin parameter" is the setting data for the return to origin operation.
(for M12 connector socket) For unused branch connector (OUT). 1: Refer to page 12 for wiring. 2: Refer to page 47 for display 42 No.EX-OMS0014-A Mounting and Installation Installation Refer to the drawing below. NOTE Tighten the screws while holding the SI unit and the supply/exhaust block assembly so that there is no gap between them.
Installation 42 Wiring 44 Specifications 48 Specifications 48 Dimensions 48 Maintenance 49 Troubleshooting 50 Option 55 -2No.EX-OMI0003-H Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Weight9 kg 35 For option T : 42 EMC Directive 2004/108/EC Standard CE Mark Machinery Directive 2006/42/EC *1 Use the product in conditions where freezing will not occur.
Disassembly Drawing] (P41-42). Note 3) "Z" in Part No. (9) indicates semi-standard specifications. The pressure unit: psi. The temperature unit: oF. Note 4) Refer to section [4.
F90 Setting of all functions 42 F97 Copy function 44 F98 Check of output 46 F99 Reset to the default setting 48 Other Settings 49 Maintenance 52 If the security code is forgotten 52 Troubleshooting 53 Specifications 61 Dimensions 64 -1No.PS-OMM0007-I Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Nominal thread size Tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm Rc(NPT)11/4 40 to 42 Nm Rc(NPT)11/2 48 to 50 Nm If the tightening torque is exceeded, the product can be broken. If the correct tightening torque is not applied, the fittings may become loose. Avoid any sealing tape getting inside the piping.