Search Results "LEJB40S2T-400-S2"

(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).

ripple 10% or less) Current consumption 20mA or less (without load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C in stock (no freeze nor condensation) Environmental resistance Voltage resistance 1000VAC for 1 min between external terminals and case Insulation resistance 50M or more (500VDC) between external terminals and case Vibration resistance 4.9m/s2

2.5% F.S. or less Note 3) No-voltage input (solid state switch or reed switch), input 5ms or more IP65 Operating: 0 to 50C, Stored: 10 to 60C (With no condensation or freezing) Operating and stored: 35 to 85% RH (With no condensation) 250VAC for 1 min, between all lead wires and enclosure 2M or more (at 50VDC) between all lead wires and enclosure 10 to 500Hz with 1.5mm amplitude or 98m/s2

Step Axis Movement mode Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 2 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 0 Axis 3 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 1 INC 500 200.00

valve with surge voltage suppressor of 24 VDC and 1.0 W or less (manufactured by SMC) Fail safe HOLD / CLEAR / Force ON Protection Short circuit protection Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85% RH (no dew condition) Environment 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2

The method is as above in (1), (2). 147m/s2 3 times each in direction of X, Y and Z respectively (De-energized) Impact resistance 1 The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment.

Do not drop, hit or apply excessive shock (over 1000 m/s2) to the Auto switch. Otherwise damage to the internal parts can result, causing malfunction. Cautions Welding current This product has no immunity against D.C. magnetic fields, so it is not suitable for use in applications where welding takes place using D.C. inverter/rectified source.

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. (2) Observe the proper tightening torque for mounting an auto switch.

Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. (2) Observe the proper tightening torque for mounting an auto switch.

Caution Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.

Warning Do not drop, bump or apply excessive impacts (300m/s2 or more for reed auto switches and 1000m/s2 or more for solid state auto switches) while handling. Although the body of the auto switch may not be damaged, the inside of the auto switch could be damaged and cause malfunction. 2. Observe the proper tightening torque for mounting an auto switch.

Start flag 0: no send Numerical data input 2 1: send 1 Step data No 0 to 63 Data writting 3 Operation Note) 1 1: Absolute 2: Relative 4 H 5 L Speed 2 0 to 65500 mm/s 6 3 7 2 Position 4 +/-2147483647 0.01mm 8 1 9 0 ID1 Numerical 10 H 11 L Acceleration 2 0 to 65500 mm/s2 data input 12 H 13 L Deceleration 2 0 to 65500 mm/s2 Data writting 14 Pushing force 1 0 to 30 10% 15 Trigger LV 1 0 to 30

Start flag 0: no send Numerical data input 16 1: send 1 Step data No 0 to 63 Data writting 17 Operation Note) 1 1: Absolute 2: Relative 18 H 19 L Speed 2 0 to 65500 mm/s 20 3 21 2 Position 4 +/-2147483647 0.01mm 22 1 23 0 24 H ID1 Numerical 25 L Acceleration 2 0 to 65500 mm/s2 data input 26 H 27 L Deceleration 2 0 to 65500 mm/s2 Data writting 28 Pushing force 1 0 to 30 10% 29 Threshold 1

Storage temperature -1060(No freezing) Storage humidity 90%RH or less (No condensation) Vibration 4.9m/s2 (0.5G) or less Enclosure IP20 Mass 200g (screw mount type) 220g (DIN rail mount type) 12 - 3. 2 Details of parts Details of parts of the gateway unit (2) (3) (4) (5) (6) (7) No.

Do not drop, bump or apply excessive impacts (1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Pilot exhaust method Body ported Lubrication Mounting orientation Shock/Vibration resistance (m/s2) Note 2) Not required Unrestricted 150/30 Dustproof ( M8 connector conforms

Non-locking push type Manual override Lubrication Mounting orientation Shock/Vibration resistance (m/s2) (2) Not required Unrestricted 300/50 Dustproof Note 1) Based on dynamic performance test, JIS B 8374-1981.

Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.

Long service life (Over 20 million cycles) VHS Max. operating pressure Pilot air pressure Ambient temperature and operating fluid temperature 1.0 MPa 0.1 to 1.0 MPa 10 to 60C (1) Impact/Vibration resistance (m/s2) (3) Lubrication Not required (2) Dustproof (Enclosure class 0) (4) 150/50 Enclosure Note 1) Use dry air to prevent condensation when operating at low temperature.