With 1 shock absorber (Set on the driving cylinder side when packed.) 25 B 32 BS 40 Standard stroke Long stroke * Refer to p.3.8-10 for minimum strokes for auto switch equipped style. Applicable auto switches/Refer to p.5.3-2 for further information on auto switch.

Note 4) Except valve weight 20 Series SQ1000/2000 SQ1000/Flat Cable Kit Stations SS5Q13JD0 L4 L3 5.25 L2 49.5 47 10.3 L1 M5: External pilot port Indicator light P = 11.5 19.2 47.8 25 20.5 1.5 1.5 Manual override (mounting hole dimension) 113 {double (double solenoid) dual 3 port valve} 108.5 {single, double (latching)} 34 10 4.6 122 (3 position) (108.5) A A A B A B A 2.PUSH 2.PUSH 94 1.TURN

Body size Port size Port M5 01 Nil M5 01 1(P), 2(A), 3(R) M5 IR-A A Body ported 8 1 Without sub-plate M5 IR Base mounted B Position for port P1 8 1 IRV 3 VEX1 3 10 G 5 VEX VEX SRH Regulator valve Option Bracket Foot Pressure gauge Silencer for bleed port Dimensions of port P1 B F G SRP Type Precision regulator Operation Air operated type Manual knob type Fixed orifice SRF

X465 0.1 to 1 0.001 Specifications Set pressure range (MPa) Desolution of setting and display (MPa) Class 10 With M5 fitting (Applicable tubing O.D. 6) Cleanliness Bleed hole Pressure switch 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With reverse connection protection) 40 mA or less Power supply voltage IR1000/2000: With M5 fitting (Applicable tubing O.D. 6) IR3000: Rc 1/2 female thread

E P.450 to 457 AV AF Made to Order 0.4 MPa Setting (-X406) The maximum set pressure is 0.4 MPa. When a pressure gauge is included, the display will show a range from 0 to 0.7 MPa. q P.456, 457 0.85 MPa Setting (-X2068) The maximum set pressure is 0.85 MPa.

When the product is mounted using the bracket, fix with M5 screws (2 pcs.) or equivalent. The Bracket thickness is approx. 1.6 mm.

A 24 V100 M5 thread 8 deep, with or without insert depending on base material. SY 32 SYJ A' VK Coding stud.

A 24 M5 thread, depth 8 With or without insert depending on base material. 32 A' Coding stud M5 x 10 DIN913-45H 12 2 8 M5 Drive flange face G1/4 DIN/ISO228/1 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 1.5 IP 3 IW 1301 AW The solenoid valve can be attached with 2 mounting bolts.

I"P.1/4, .. . , ASP530F-N03-11 S 3/S' ~ 25.9 1 51Jtr 11 / 16" 28.6 ~6~5 ~ 61 ;a.: ~:B-.9 :2D.S 220 tU6' /36,3 . 34:7 .26~ 21.7 . . ~ A efertlllCe dll'l'lerlSlons 1 01 NPT Ihmads aller installalion 3 Speed Controller 5 . ASP w"" P;lo' Ch.,k V,'v. efles Construction Parts list .QesCr;plian ' ''' fi1t~lal , . . .

B Counter bore depth C 4-LD Thread depth M QW PB N A E depth EK Q + Stroke Z + Stroke G A A LW Stroke adjustment screw (inner cover) Note 2) Note 3) Note 2) Operating direction Plug [P (port g)] Plug [P (port h)] P (port a) P (port b) 0.5 0.5 Plug [P (port c)] Plug [P (port e)] Left Right Auto switch mounting groove HI HP H HL HG HT HS HB HA HB HA HG HT HI Note 3) Plug [P (port d)] Plug [

5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil R Metal seal Double FJG Rubber seal 1 (P) 5 (R1) 3 (R2) Rated coil voltage (A) 4 (B) 2 Option 3 4 24VDC FIG 12VDC Nil None 1 (P) 5 (R1) 3 (R2) Voltage other than above (50VDC or less) Indicator light with surge voltage suppressor 9 Z A02 VS1 01

(Unit: %) H 140 80 80 Sets the position loop P constant. *Please perform the actuator operation after changing this parameter setting under the responsibility of the user. Position loop P constant A 140 110 110 1 to 200 B 100 80 80 C 110 80 80 H 80 140 140 Sets the speed loop P constant.

Please refer to P.125. Specifications AP3200 Normally closed (N.C.)

RB RZQ Mounting Bolt J C CR D 110 135 160 120 145 170 130 155 180 135 160 185 CH Model RZQB32-25RZQB32-50RZQB32-75RZQB40-25RZQB40-50RZQB40-75RZQB50-25RZQB50-50RZQB50-75RZQB63-25RZQB63-50RZQB63-75Mounting bolt M5 x 110l M5 x 135l M5 x 160l M5 x 120l M5 x 145l M5 x 170l M6 x 130l M6 x 155l M6 x 180l M8 x 135l M8 x 160l M8 x 185l D9.5 8 -X 10 8.5 20Data 16.5 11.5 3 17.5 12.5 3.5 10-10-5 6

Applied voltage When connecting fittings to valves, tighten as indicated below. 1) M3, M5 types 1. When using SMC fitting, follow the guidelines below. After tightening by hand, tighten an additional 1/4 (M3), 1/6 (M5) turn with a tightening tool. However, if miniature fittings are used, tighten an additional 1/4 turn with a tightening tool after tightening by hand.

rev) n [Type of Motor: S6,S7,S8] Absolute 18bit encoder (Resolution: 262144 p/rev) Encoder [Type of Motor: T6,T7,T8] [With LECSB-T/LECSS-T] Absolute 22bit encoder (Resolution: 4194304 p/rev) [With LECSC-T] Absolute 18bit encoder (Resolution: 262144 p/rev) Type Note 5) No excitation operating type unit Lock spec Holding force [N] 78 131 255 131 197 385 220 330 660 Power consumption [W] at

8.4 NO X X PE NC 30.5 30.5 116.1 98.6 91.6 91.6 2(A) 3(R) 66.8 57.6 1(P) 43.8 43.8 34 34 71 (P port) Rc 1/2, 3/4, 1 (R port) Rc 1/2, 3/4, 1 (A port) Rc 1/2, 3/4, 1 5-5-12