Actuation: 1 (2-Position Single), Electrical Entry: L (L-type Plug Connector), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: N (NPT)
wire P P Y59B Y69B 12V p Solid state switch Relay PLC 3 wire (NPN) P P Y7NW Y7NWV Grommet p 24V Yes 5V 12V IC Diagnostic indication (2 color) 3 wire (PNP) P P Y7PW Y7PWV p P P Y7BW Y7BWV p 12V 2 wire Water resistant (2 color) P Y7BAL p P Available -Not available * Lead wire length symbol 0.5m () (Example) Y69B 3m L Y69BL 5m Z Y69BZ **Solid state auto switches marked with a "p" are manufactured
Real-time switch output Unit switching Hysteresis mode ON For Air YES OFF P-1 P-2 Display Real-time flow rate l/min Accumulated flow l Real-time flow rate "P" Window comparator mode H : Hysteresis CFM x 10-2 x CFM x 10-1 ft3 x 10-1 H H CFM = ft3/min ON High Flow Rate Type (For Air) NO OFF P-1 P-2 Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 Real-time flow rate OUT1
*r-r-r --r| | | a High-speed | | | response time I I I specifications t t l | | t---{ Pressure display unit | | t--fMfi--l | | f--fkof/cm, l I I [s-f b "t| | I-+-fEr_--] | | tsT kp " ] t l t l I I Cable connector type I S I Straiqht tvpe 3 m I I L I Riqht anqle tvpe 3 m I I j N lWithout cable connector I l L-Bracket Model 7 . l00O tvoe v : 2000 tvoe Pressure [rPa 2 kqf/cm, 3 bar 4 PSI kPa
Various actuators Applicable Manifold Solenoid Valves SY Series (IP67) SV Series (IP67) S0700 Series (IP40) VQC Series (IP67) 5 C O N T E N T S Wireless System EX600-W Series Wireless slave unit Wireless master unit Accessories How to Order qEnd Plate Bracket p. 17 Wireless Unit p. 7 wValve Plate p. 17 Digital Input Unit p. 7 eReinforcing Brace p. 17 Digital Output Unit p. 7 rSeal
0.6MPa 40 40 Holding force (N) Holding force (N) 0.5MPa 0.5MPa 30 30 L L 0.4MPa 0.4MPa 20 20 0.3MPa 0.3MPa 10 10 0.2MPa 0.2MPa 0 0 10 20 30 40 50 60 10 20 30 40 50 60 Holding point L(mm) Holding point L(mm) MHK2-20D MHK2-20D 80 60 70 Pressure 0.6MPa Pressure 0.6MPa 50 60 Holding force (N) Holding force (N) 50 40 0.5MPa 0.5MPa 40 30 0.4MPa 0.4MPa 30 20 0.3MPa 0.3MPa 20 10 10 0.2MPa 0.2MPa
Mounting Amplifier Single mounting Ho.izontally Q r A vertica,,y F Multiple mounting + -f -t] + -ti n n n h n t t t l t t l t I i u ! L l !
Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) 1. Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2.
Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2. Confirmation of allowable lateral load In the same way, the lateral load at L=50mm and P=0.4MPa is 48N from the graph.
(Station 1) Light/Surge voltage suppressor Side A: Orange Side B: Green 18.9 (DIN rail dimension) (62.4) ON ON 43.5 OFF OFF (7.5) 34.2 Switch (when equipped with switch) Internal pilot manifold L: Dimensions n: Stations (n1 + n2) External pilot manifold L: Dimensions n: Stations (n1 + n2) L n 2 110.5 100 81 15 L n 2 123 112.5 91.5 16 3 123 112.5 91.5 16 4 135.5 125 102 17 5 148 137.5 112.5
Head side flange style 32 mm 0.5 m 3 m Nil L n Double clevis style n pcs. 40 mm 50 mm Applicable counter 63 mm Connector Series CEU1 Series CEU5 Nil Z With connector Without connector Suffix for cylinder (Applicable bore size 40 to 63) Standard cylinder stroke (mm) Refer to Standard Stroke on page 10-12-19.
258-9200-www.stevenengineering.com 2-N through 4-O thread depth R Metal connector 500 or 3000 M14 x 1 B + Stroke A + Stroke A B C D E G H I K L M Bore size (mm) 12 20 Standard stroke 25, 50, 75, 100, 125, 150 94 M5 x 0.8 16 5.2 25 15.5 69 15 6 25 42.5 25, 50, 75, 100, 125, 150, 175, 200 106 M8 x 1.25 10 8 28 25.5 78 15.5 10 36 53.5 Q R T V Y N O P Bore size (mm) 12 20 47 7 53.5 22 7 M4
Nil Rc F G (with Rc-G conversion fitting) N NPT (with Rc-NPT conversion fitting) Power supply 40 3-phase 380 to 415 VAC (50/60 Hz) Specifications Model HRSH100-Al-40-l HRSH150-Al-40-l HRSH200-Al-40-l HRSH250-Al-40-l HRSH300-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.27 2.1 2.1 2.8 2.8 Control method PID control Ambient temperature/Altitude
L H M N 4 to 0.5 [4 to 13 mm] Drain tube (O.D.: 0.4 [10 mm], Length: 35.4 [0.9 m]) [115 VAC specification] Power cable with plug (Length: 110 [2.8m]) [230 VAC specification] Power cable outlet 0.7 [17 mm] (Wire diameter 0.4 [9 to 11mm]) Dimensions Unit: inch [mm] A B C D E F G H J K L M N P Model Port size 30.5 [775] 23.6 [600] IDFB22E 1 11.4 [290] 24.5 [623] 5.3 [134] 15.9 [405] 27.5 [698
L/min 42/56 Pump capacity Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50/60 Hz Note 7) L/min 28/42 Tank capacity L 18 Circulating fluid outlet, circulating fluid return port Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) Pump drain port Rc1/4 (Symbol F: G1/4, Symbol N: NPT1/4) Automatic fluid fill system (Standard) HEA IDH Supply side pressure range
Air Cylinder/End Lock Series MBB 32, 40, 50, 63, 80, 100 How to Order MBB L 32 50 H N Standard H N L 32 50 A53 MDBB With auto switch Number of auto switches Built-in magnet S 3 n 2 1 3 n Mounting Manual release Basic/Without bracket Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion B L F G C D T Bore size N L Non-locking Locking 32 40 50 63 80 100 Without auto
8 x L counter bore J J A + Stroke M M Rod end male thread CHKDB20, 25 CHKDB32 to 100 Water resistant type S N g C B + Stroke h + Stroke A + Stroke Rod end male thread (mm) B C D E F G H J K L M P Q R A Bore size (mm) 20 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 9.5 depth 5.4 43 1/8 16.5 6 25 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 9.5 depth 5.4 49 1/8 17 8 32 61 51 10 18 14 M12 x 1.75 15 7 47 6.6
entry Indicator light Wiring (output) 0.5 (Nil) 3 (L) 5 (Z) None (N) Applicable load DC AC Vertical Lateral Vertical Lateral 3 wire (NPN equiv.)
min) Maximum ow rate 50/60 Hz 14.5 to 17.9 gal/min (55/68 L/min) Maximum pump head 164 ft (50 m) Minimum operating ow rate 50/60 Hz Note 7) 7.4/11.0 gal/min (28/42 L/min) Tank capacity 4.75 gal (18 L) Circulating uid outlet, circulating uid return port Rc3/4 (Symbol F: G3/4, Symbol N: NPT3/4) Tank drain port Rc1/4 (Symbol F: G1/4, Symbol N: NPT1/4) Automatic uid ll system (Standard) Pump
(No protrusion from the rod end) P . 43 Low speed: Series CUX 2 Series CU Precautions on Free Mount 1.