Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.
Cart SMC SY100-30-1A-15 connector assy, SY3000 SOL/VALVE, RUBBER SEAL*** $3.34 Add to Quote Add To Cart Add to Cart SMC SY100-30-1A-20
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 1/8, Option: Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator, Attachment: Standard, Semi-Standard 1: w/Bowl Guard, Nylon Bowl, Semi-Standard 2: Standard
20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa 0.2MPa 0.2MPa 100 200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
6 q w e r t y u i Block packing !
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Fittings & Tubing Air Cylinders Rotary Actuators Angle adjustment range 3 Angle adjustment range 3 Angle adjustment range 3 Key Key +4 0 0 0 +4 0 9 y 9 A port B port 0 y A port B port a a w 0 w 1 y y e ay e k k 80 w of of y e e ke 1 g g n n f ay ra a o r n n w ge io io at ey n ot at R ra ot k R Angle adjustment range 3 n of io at e +4 0 ot R ng R ot ra at n 80 io io at 1 n ot R ay ra +4
When knob q is adjusted downwards, adjusting spring w is compressed. The inlet valve r is opened allowing air flow to the outlet. Air outlet pressure balances against diaphragm e and adjusting spring w. When the outlet pressure is higher than the set pressure, the inlet valve r is closed and exhaust of the excess outlet pressure takes place through the adjusting spring cover bleed.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)