MA Auto switches marked with a symbol are produced upon receipt of order. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ DNote 1) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper.
5 19 (Piping port) M5 x 0.8 L plug connector (L): 10-V1 4(A)-L-M5 1 2 M plug connector (M): 10-V1 4(A)-M-M5 1 2 13.1 (Light/surge voltage suppressor) (Light/surge voltage suppressor) + 3 Approx. 300 3 (Lead wire length) 39.6[46.6] Approx. 300 <43.5> (Lead wire length) + 40.7[42.9] <42.9> 30.9[33.1] <33.1> 25.9 2 2 Other dimensions are same as grommet style.
) Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication Port size M E D Differential pressure indicator Differential pressure indication switch Note) 04 06 08 10 12 16 20 24 28 32 1/2B None (Blanking cap) 3/4B Note) N.C. and N.O. common 1B 1 1/4B Nominal filtration 1 1/2B 074 105 149 74 m 105 m 149 m 2B 2 1/2B 3B 3 1/2B M Micromesh Element 4B FH FH Note) For flange
Output type Current consumption PF3W721--A(-M) NPN open collector output 50 mA or less Flow switch SMC PF3W721--B(-M) PNP open collector output 50 mA or less 3.3 Installation HRS Series 3-20 HRX-OM-W032 Chapter 3 Transport and Setting Up 1. Prepare the flow switch described in the Table 3-8(sold separately). 2.
IDX-OM-W026-A / Series IDF22E-20(-A,C,K,L,M,R,T) IDF22E-30(-A,C,K,L,M,R,T) IDF37E-20(-A,C,K,L,M,R,T) IDF37E-30(-A,C,K,L,M,R,T) IDF55E-30(-A,C,L,M,R,T) IDF75E-30(-A,C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2 ) *1) ISO4414Pneumatic fluid power General rules and safety requirements
ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 V A M W 1 1 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 4) 2) 1) 3 300L/min(ANR) M 0.35MPa *2 P 6 600L/min(ANR) H 0.50MPa 3)P V/ *23 (V) (P) 5/ 06 Rc3/4 K1 N.C.+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.
Note Conductor resistance /km, 20C 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 10 Cable 25 cores x 24AWG AXT100-DS25-030 Voltage limit VAC, 1 min. 1000 AXT100-DS25-050 L For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Note) The min. bending radius of D-sub cable is 20 mm.
ML2B / W1 ML2B / M1 0 0 0 0 Momentum Nm 0 0 Load N 0 Piston Speed m/s Piston Speed m/s ML2B / W2 ML2B / M2 Momentum Nm Load N Piston Speed m/s Piston Speed m/s ML2B / W3 ML2B / M3 20 10 Momentum Nm 5 Load N 3 2 1 Piston Speed m/s Piston Speed m/s ML2B / W4 Allowable Kinetic Energy 00 H or izontal M ounting 100 5 00 Ver tical M ounting 50 Load N 0 0 1 00 Load N 0 50 5 Piston Speed
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900
: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
Manifold additions 1 Install a passage pipe assembly in between the manifold bases. 2 Connect the respective manifold bases with a connecting plate assembly. [Tightening torque: 0.90.1N m (0.670.07ftlb] 3 Attach brackets to the manifold bases.
L M L CXTM L Series Action Double acting/Single rod Double acting CY1B: 6 10, 15, 20 25, 32 40, 50, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 12, 16, 20 25, 32, 40 50, 63, 80 100 20, 25 32, 40 50, 63 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 10, 16 20 25, 32 12, 16 20, 25 32, 40 6, 10 15, 20 25, 32 6, 10 16 20, 25 32, 45 6, 10 16 20, 25, 32 40, 50 10, 15 25 12, 16 20, 25
20 13.3kPa 13.3kPa 10 10 0 0 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 Time to reach vacuum [S] Time to reach vacuum [S] Viewing the graphs The graphics indicate the time required to reach a vacuum pressure determined by adsorption conditions for work pieces, etc., starting from atmospheric pressure in a 1l sealed tank.
4.5 53.5 53.5 9 9 38 9 B B 20 14 12 P = 43 A P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B (2n 1/8) 4n-1/4, 3/8 2, 4 port PA L-side R-side L-side R-side D-side D-side 89 3 89 16 141 (Single) 141 (Single) 55 44 186 (Double) 186 (Double) 196 (3 position) 196 (3 position) 77.5 Bottom ported M12 connector L: Dimensions n: Stations 141.5 L n 1 Formula 2 3
DC() IN (1 to 5 V) Analog output or auto shift input Gray 2 DC(-) Blue 1 20 2 m 20 With bracket A 30 20 46 4.2 10 15 40 31.5 26.5 1.6 7.2 22 35 41 A View ZS-28-B Bracket With panel mount adapter With panel mount adapter + Front protective cover 42.4 34.5 24 7 34.5 24 11 Panel thickness 0.5 to 6 ZS-27-D Panel mount adapter + Front protective cover 8.75 ZS-27-C Panel mount adapter 6 Series
5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance
5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance
It is possible to manufacture it with a switch. Note) The -X126 model cannot be manufactured with an L plug connector for electrical entry. Therefore, use a grommet type or an M plug connector.
Stroke ST (mm) 0 4 6 8 10 15 20 Caution Stroke ST (mm) When driving an inertial load, operate a cylinder with kinetic energy within the allowable value.