SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2KD16-200Z-NW-A"

Accuracy: H (High Precision Type), Size: 32, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Motor Type: NW (Mounting Type W), Lead Screw: C [LEYG25, 3mm; LEYG32, 4mm, (5)], Stroke: 300mm

Flange Size: 16, Flange Type: KF(NW), Port Direction: Left Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Flange Size: 25, Flange Type: KF(NW), Port Direction: Left Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Flange Size: 40, Flange Type: KF(NW), Port Direction: Left Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Flange Size: 25, Flange Type: KF(NW), Port Direction: Rear Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Valve Type: In-line Type, Normally Closed, Bellows Seal, Flange Size: 40, Flange Type: KF (NW), Port Direction: w/Indicator, Right Flange Surface, Temperature: -, Suffix: -, Auto Switch: -, Lead Wire: -, Number: -, Seal Material: -, Seal Replacement: -

Flange Size: 16, Flange Type: KF(NW), Port Direction: Rear Flange Surface, Temperature: 5 to 60°C, Version: Refresh, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Flange Size: 25, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Flange Size: 25, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Flange Size: 80, Flange Type: KF(NW), Port Direction: Flange Side, Temperature: 5 to 60°C, Version: 2 (Refresh), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)

Valve Type: XMD (Angle Type, 2 Stage Control, Single Acting, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C)

Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet)

Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet)

Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 50, Flange Type: KF (NW), Port Direction: G (w/Indicator, Rear Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet)

Valve Type: XYD (In-line Type, 2 State Control, Single Acting, Bellows, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C)

Valve Type: XYD (In-line Type, 2 State Control, Single Acting, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C)

Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 25, Flange Type: KF (NW), Port Direction: F (w/Indicator, Left Flange Surface), Temperature: 5 to 60°C (or n/a for XMH/XYH), Suffix: , Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR, DBL ACT, DBL ROD, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, NW, 50MM CG DOUBLE-ROD, 4.98244 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CG1Double rod typeCG1WDouble acting, Double rodExcept with rubber bumper666