SMC Corporation of America
Elite Part Number Search
Search Results "AMS60A-N10C-SA-KLE"

Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to

Model Type: Standard, Piping: Direct, Port Size: 14 [1 1/2" (40A)], Port Thread: NPT, Silencer: w/Silencer, Pilot Port Size: 1/4", Orifice Diameter: Pilot Valve Orifice Diameter: for ø3mm to ø5mm

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate

Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate

Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1.6 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration

Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: G 1/4, ISO 1179-1 Compliant, Orifice: Orifice shipped with the Product, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Body Size: 50, Model Type: B (Air Filter + Regulator), Thread: N (NPT), Port Size: 10 (1), Float Type Auto Drain: C [N.C. (Normally Closed)], Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter

Body Size: 50, Model Type: Air Filter + Regulator + Lubricator, Thread: N (NPT), Port Size: 10 (1), Float Type Auto Drain: C [N.C. (Normally Closed)], Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None,

Body Size: 50, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 50, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: ST (S + T), Semi-Standard 1: 38 (3 + 8), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 55, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: S (Pressure Switch), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)

Body Size: 60, Thread: N (NPT), Port: 10 (1), Option: C [Float Type Auto Drain (N.C.)], Attachment: S (Pressure Switch), Semi-Standard 1: 16 (1 + 6), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)