Valve Size: 4 (Series: 40), Valve Type: 1 (N.C.), Body Material: S (Stainless Steel), Seal Material: T (Fluororesin), Port Size: 25A (1), Thread Type: F (G), Head Size: 4 (ø63), Head Material: S (Stainless Steel)
Valve Size: 4 (Series: 40), Valve Type: 1 (N.C.), Body Material: S (Stainless Steel), Seal Material: T (Fluororesin), Port Size: 25A (1), Thread Type: R (Rc), Head Size: 4 (ø63), Head Material: S (Stainless Steel)
N.C. 6A 8A 10A 10A 15A 20A 25A 32A 32F 40A 40F 50A 50F 1 8 1 4 3 8 3 8 1 2 3 4 7 1 15 2 20 3 25 4 1 1 1 4 32 5 11 4 B Flange 11 2 40 6 11 2 B Flange 2 50 7 2B Flange 634
Rc G NPT NPTF Nil F N T None With bracket Nil B Valve type 1 3 N.C./3.5 MPa N.C./7.0 MPa Electrical entry/With light/surge voltage suppressor D DIN terminal Seal material DZ DIN terminal with light/surge voltage suppressor A B NBR seals FKM seals Rated voltage Valve size Port size 3 2 1 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 10A 15A 20A 25A 1 2 3 4 3 8 1 2 3 4
Size: 4 (ø25), Valve Type: 0 [NC (Operating Pressure 1MPa)], Body Material: S (Stainless Steel Body), Thread: T (NPTF), Port Size: 25A (1)
Size: 4 (ø25), Valve Type: 0 [NC (Operating Pressure 1MPa)], Body Material: Standard (Bronze Body), Thread: T (NPTF), Port Size: 25A (1)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: None, Actuation Type: B (N.O., Normally Open)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: L (Indicator Light), Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: L (Indicator Light), Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: V (Vacuum/Low Pressure), Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: S (Surge Suppressor), Actuation Type: B (N.O., Normally Open), Pilot: 1 (External Pilot)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: T (NPTF)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: None, Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: L (Indicator Light), Actuation Type: B (N.O., Normally Open)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: 1 (External Pilot), Thread: T (NPTF)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: Z (Light/Surge Suppressor), Actuation Type: B (N.O., Normally Open), Pilot: Standard (Internal Pilot), Thread: N (NPT)
Body Size: 6 (1), Valve Option: for General, Port Size: 10 [1 (25A)], Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light/Surge Suppressor: S (Surge Suppressor), Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: N (NPT)