wire length 300 mm L: With lead wire (Length: 300 mm) M: With lead wire (Length: 300 mm) MN: Without lead wire D: With connector * Only with solenoid Manual override Grommet/ (L/M) plug connector DIN terminal H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector Nil Non-locking push type Grommet/ (L/M) plug connector B Locking slotted
3(R) NC 1(P) Switch mark (Mounting hole) 2-5.2 (R port) Rc 1/4, 3/8 47 41.6 69 68 29.5 28.5 22.5 13.5 (P port) Rc 1/4, 3/8 Rc 1/4, 3/8 A B Base mounted: VPA544V(A port) 13.5 91.4 57 47 13.5 (PA port) Rc 1/8 NO 2(A) 32 42 52 PA 3(R) NC 1(P) Switch mark Rc 1/4, 3/8 47 2-5.2 (Mounting hole) (R port) 41.6 69 68 29.5 28.5 22.5 13.5 Rc 1/4, 3/8 (P port) 5-5-18 7 3 Port Air Operated Valve Series
Use the arrow keys ([], []),to select D E V I C E SER REMOTE. Figure 5-48 Mode Selection screen 5. Press the [ENT]key. HRZ Series 5.4 Examples of System Operation 5-39 5-39 HRX-OM-X010 Chapter 5 System Operation 5.4.3 Example 3: PUMP IV is switched from FLOW to FREQ. POWER ON Figure 5-49 Swiching of pump operation from FLOW to FREQ 1. Press the [SEL] key to display the Menu screen.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
Range Back Pressure SMC 22 8.0 -750mmHg~58psi 0~100C 0~30psi (60psi) 136 150 75 Height Width Operator Dia. 1 LVQ60 LQ Seal Locations N u t S e a l L o c k T ubing Support T aper Surface T u b i n g T r ap e zoidal T h re a d s I n s e rt Bushing Nut Lock U.S. Patent #5,996,636 Quadruple Seal Maximum leak protection. Up to 215psi @ 200C.
Pilot air supply port (A I R S UP) S upplying pressure set by regulator. Use clean air. Pilot air exhaust port (A IR E X H) E xhausting pilot air. Reset F or resuming of normal operation after momentary stoppage. of 0 .2 mm at least on IN port. Diaphragm should be changed before the life frequency.
Type Auto switch model Applicable magnetic eld Electrical entry Indicator light Wiring (Pin no. in use) Load voltage Lead wire length Applicable load D-P3DWASC 2-wire (34) 0.3 m Pre-wired connector Relay, PLC Note 1) D-P3DWASE 2-wire (14) D-P3DWA Grommet 2-wire 0.5 m D-P3DWAL 3 m D-P3DWAZ 5 m AC magnetic eld (Single-phase AC welding magnetic eld) Solid state auto switch 2-color indicator
M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
Lead wire with connector ZS-38-3L 3 cores for 1 output, 2 m Lead wire with connector ZS-38-4L 4 cores for 2 outputs, 2 m Lead wire with connector + connector cover ZS-38-3G 3 cores for 1 output, 2 m Lead wire with connector + connector cover ZS-38-4G 4 cores for 2 outputs, 2 m Lead wire with connector for copy function ZS-38-5L 3 cores (for copy function), 1 m Lead wire with connector unit
SMC CMD:same as existing HEC To return all of the setting values to default: Turn on the power supply SMC CMD 3 Communication SMC CMD E Handle L Facility water IN communication Modbus while pressing [SEL] and [RET] keys. protocol F Model No. label M Facility water OUT Modbus:Modbus communication G Power supply connector N Dain port 10 Troubleshooting Continued Reason for alarm Code Description
In Japan, according to METI, pipe thread (Rc, R, NPT etc) should not be used as connections of piping, ttings, and valves installed in gas systems.
Displ m Displ m Block diagram spring Compd. spring Compd. m M Pa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m 2 Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: C8 [ø8 (5/16") One-touch Fitting], Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/4, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/4, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve