Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (

Style: Pressure Switch w/ T-Spacer, Body Size: 20 (AC20), Thread Type: N (NPT), Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ T-Spacer, Body Size: 30 (AC30), Thread Type: N (NPT), Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ L-Shaped Piping Adapter, Body Size: 20 (AC20), Thread Type: N (NPT), Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Pressure Unit of the Scale Plate: MPa, Lead Wire Length: L (3m), Mounting Position: Right

Style: Pressure Switch with Piping Adapter, Body Size: 20 (AC20), Thread Type: N (NPT), Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa, Mounting: Right

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: A4 [Bracket D for M12 Connector Type (ZS-46-A4)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type)

Size: 46 (42.5 O.D.), Display Pressure: 10 (1.0MPa), Connection Thread: N01 (NPT 1/8), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten)

Size: 46 (42.5 O.D.), Display Pressure: 4 (0.4MPa), Connection Thread: N01 (NPT 1/8), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten)

Body Size: AC20, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa, Mounting: Right

Style: Pressure Switch w/ L-Shaped Piping Adapter, Body Size: AC20, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.4 MPa, Pressure Unit of the Scale Plate: MPa, Lead Wire Length: 3m, Mounting Position: Right

Style: Pressure Switch w/ T-Spacer, Body Size: AC20, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ T-Spacer, Body Size: AC30, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa

Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: -, Option 3: -