HECR 5-14 MODBUS communication function 5.10.3 Control operation mode The control operation mode is assigned as follows.
After starting 475 field communicator's OS, synchronization with the Air Servo Cylinder automatically starts. 14 10.
Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. P1 = 0.1 MPa 0.04 0.04 0.02 0.02 Selection Warning 0 0 15000 10 5000 0 2000 4000 6000 0 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Piping 1. Do not introduce air from the outlet side as this can damage the damper. 1.
With double acting spring 20 14 32 20 50 32 63 40 63 40 80 Bore size (mm) Rod size (mm) 50 Standard stroke (mm) Standard variations Series Variations Option Bore size (mm) 15 20 30 40 Rod end shape Series Mounting type Actuation system Built-in magnet With lock mechanism With proximity sensor With cancel 20 32 Double acting RSH Adjustable Flange Lever Double acting spring type 50 63 80 RS1H
(Do not use a tool.) The initial exhaust rate is adjusted by turning the nut anti-clockwise.
Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46
Do not use a tool when rotating the handle. When the handle is rotated with a tool, it may apply excessive torque to the handle or inside the valve body and it may cause damage. Rotate the handle by hand. 9. When locking the valve with LOTO feature in the closed position, use safety lockout hasp.
Unused Lead wire assy U side 6 stations (14 stations) Pin Confirm an insertion of the lead wire assembly after the insertion of pin by light pulling of the lead wire. (n) 4. Mount the end plate !2 and !3 and tighten the bolt !1. 7 stations (15 stations) (2) (1) Stations Note 1) Be careful that the packing and the O-ring do not fall out of the groove.
Connect End Plate and tighten removed screws by specified tightening torque. (0.6 Nm) SW1 SW2 SW3 SW4 SW5 SW6 Node ID Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Refer to the valve catalogue for valve manifold dimensions. 1 ASInterface line (+) AS-i + 2 4 (0 V) RESERVE 2 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Pin Allocation 4 Over current protection Yes 1 UT1 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. SF and BF Indicators Yes Over current detection 2 DI (Input signal "n+4") FS LED 3 1 BF SF Description 3 0V (US1) Fieldbus Do not operate the product outside of the specifications.
Input (Only connector "0") 2 1 2 Input No.1 1 3 Power supply (0 V) 1: Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly inputted the input connector "0". 2: N.C.: Not connected 5 3 4 Input 4 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. EX9-PE1 power input connector No.1 M12 5-pin plug B-code Element No.
Caution Operating Condition (1) Do not use in atmosphere containing corrosive gas, chemicals or exposed to sea water or vapor. (2) Do not use where vibrate or exposed to impact. (3) When heat source exist nearby, protect the regulator from the radiation heat.
Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within 1G 60Hz. ! ! ! ! -6- 7. Maintenance Warning (1) If handled improperly, compressed air can be dangerous.
Connection 1) Rc connection Confirm that chips from the pipe threads and sealing material do not enter the piping. Also, when sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. -4- Piping Piping 2) TSJ connection The TSJ fitting is a kind of a self-align fittings.
Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within 1G 60Hz. ! ! ! ! -6- 7. Maintenance Warning (1) If handled improperly, compressed air can be dangerous.
Do not operate under the conditions listed below due to a risk of malfunction.
When mounting the load with screws, do not exceed the maximum tightening torque. (The torque may vary depending on the material of the load.) Bolt Model Maximum tightening torque (Nm) Caution MGJ6 M2.5 x 0.45 0.5 MGJ10 M3 x 0.5 1.0 1. Do not scratch or dent the sliding parts of the piston rod and guide rods. Damage to seals can cause air leakage or malfunction, etc. 2.